Cargando…

Direct Flow Medical vs. Edwards Sapien 3 Prosthesis: A Propensity Matched Comparison on Intermediate Safety and Mortality

Aims: To compare intermediate performance and mortality rates in patients, who underwent transcatheter aortic valve implantation (TAVI) with two different types of prostheses: Edwards Sapien 3 (ES3) and Direct Flow Medical (DFM). Methods and Results: 42 consecutive patients implanted with a DFM pros...

Descripción completa

Detalles Bibliográficos
Autores principales: Edlinger, Christoph, Bannehr, Marwin, Wernly, Bernhard, Kücken, Tanja, Okamoto, Maki, Lichtenauer, Michael, Hähnel, Valentin, Reiners, David, Neuss, Michael, Butter, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8249849/
https://www.ncbi.nlm.nih.gov/pubmed/34222370
http://dx.doi.org/10.3389/fcvm.2021.671719