Cargando…

Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application

PURPOSE: This study aimed to assess the influence of various micromechanical surface conditioning (MSC) strategies with or without coupling agent (silane) application on the micro-shear bond strength (µSBS) of resin- matrix ceramics (RMCs). MATERIALS AND METHODS: GC Cerasmart (GC), Lava Ultimate (LU...

Descripción completa

Detalles Bibliográficos
Autores principales: Günal-Abduljalil, Burcu, Önöral, Özay, Ongun, Salim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8250191/
https://www.ncbi.nlm.nih.gov/pubmed/34234928
http://dx.doi.org/10.4047/jap.2021.13.3.180
_version_ 1783717034798874624
author Günal-Abduljalil, Burcu
Önöral, Özay
Ongun, Salim
author_facet Günal-Abduljalil, Burcu
Önöral, Özay
Ongun, Salim
author_sort Günal-Abduljalil, Burcu
collection PubMed
description PURPOSE: This study aimed to assess the influence of various micromechanical surface conditioning (MSC) strategies with or without coupling agent (silane) application on the micro-shear bond strength (µSBS) of resin- matrix ceramics (RMCs). MATERIALS AND METHODS: GC Cerasmart (GC), Lava Ultimate (LU), Vita Enamic (VE), Voco Grandio (VG), and Brilliant Crios (BC) were cut into 1.0-mm-thick slices (n = 32 per RMC) and separated into four groups according to the MSC strategy applied: control-no conditioning (C), air-borne particle abrasion with aluminum oxide particles (APA), 2W- and 3W-Er,Cr:YSGG group coding is missing. The specimens in each group were further separated into silane-applied and silane-free subgroups. Each specimen received two resin cement microtubules (n = 8 per subgroup). A shear force was applied to the adhesive interface through a universal test machine and µSBS values were measured. Data were statistically analyzed by using 3-way ANOVA and Tukey HSD test. Failure patterns were scrutinized under stereomicroscope. RESULTS: RMC material type, MSC strategy, and silanization influenced the µSBS values (P<.05). In comparison to the control group, µSBS values increased after all other MSC strategies (P<.05) while the differences among these strategies were insignificant (P>.05). For control and APA, there were insignificant differences between RMCs (P>.05). The silanization decreased µSBS values of RMCs except for VE. Considerable declines were observed in GC and BC (P<.05). CONCLUSION: MSC strategies can enhance bond strength values at the RMC - cement interface. However, the choice of MSC strategy is dependent on RMC material type and each RMC can require a dedicated way of conditioning.
format Online
Article
Text
id pubmed-8250191
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-82501912021-07-06 Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application Günal-Abduljalil, Burcu Önöral, Özay Ongun, Salim J Adv Prosthodont Original Article PURPOSE: This study aimed to assess the influence of various micromechanical surface conditioning (MSC) strategies with or without coupling agent (silane) application on the micro-shear bond strength (µSBS) of resin- matrix ceramics (RMCs). MATERIALS AND METHODS: GC Cerasmart (GC), Lava Ultimate (LU), Vita Enamic (VE), Voco Grandio (VG), and Brilliant Crios (BC) were cut into 1.0-mm-thick slices (n = 32 per RMC) and separated into four groups according to the MSC strategy applied: control-no conditioning (C), air-borne particle abrasion with aluminum oxide particles (APA), 2W- and 3W-Er,Cr:YSGG group coding is missing. The specimens in each group were further separated into silane-applied and silane-free subgroups. Each specimen received two resin cement microtubules (n = 8 per subgroup). A shear force was applied to the adhesive interface through a universal test machine and µSBS values were measured. Data were statistically analyzed by using 3-way ANOVA and Tukey HSD test. Failure patterns were scrutinized under stereomicroscope. RESULTS: RMC material type, MSC strategy, and silanization influenced the µSBS values (P<.05). In comparison to the control group, µSBS values increased after all other MSC strategies (P<.05) while the differences among these strategies were insignificant (P>.05). For control and APA, there were insignificant differences between RMCs (P>.05). The silanization decreased µSBS values of RMCs except for VE. Considerable declines were observed in GC and BC (P<.05). CONCLUSION: MSC strategies can enhance bond strength values at the RMC - cement interface. However, the choice of MSC strategy is dependent on RMC material type and each RMC can require a dedicated way of conditioning. The Korean Academy of Prosthodontics 2021-06 2021-06-25 /pmc/articles/PMC8250191/ /pubmed/34234928 http://dx.doi.org/10.4047/jap.2021.13.3.180 Text en © 2021 The Korean Academy of Prosthodontics https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Günal-Abduljalil, Burcu
Önöral, Özay
Ongun, Salim
Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application
title Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application
title_full Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application
title_fullStr Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application
title_full_unstemmed Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application
title_short Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application
title_sort micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8250191/
https://www.ncbi.nlm.nih.gov/pubmed/34234928
http://dx.doi.org/10.4047/jap.2021.13.3.180
work_keys_str_mv AT gunalabduljalilburcu microshearbondstrengthsofresinmatrixceramicssubjectedtodifferentsurfaceconditioningstrategieswithorwithoutcouplingagentapplication
AT onoralozay microshearbondstrengthsofresinmatrixceramicssubjectedtodifferentsurfaceconditioningstrategieswithorwithoutcouplingagentapplication
AT ongunsalim microshearbondstrengthsofresinmatrixceramicssubjectedtodifferentsurfaceconditioningstrategieswithorwithoutcouplingagentapplication