Cargando…
Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application
PURPOSE: This study aimed to assess the influence of various micromechanical surface conditioning (MSC) strategies with or without coupling agent (silane) application on the micro-shear bond strength (µSBS) of resin- matrix ceramics (RMCs). MATERIALS AND METHODS: GC Cerasmart (GC), Lava Ultimate (LU...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8250191/ https://www.ncbi.nlm.nih.gov/pubmed/34234928 http://dx.doi.org/10.4047/jap.2021.13.3.180 |
_version_ | 1783717034798874624 |
---|---|
author | Günal-Abduljalil, Burcu Önöral, Özay Ongun, Salim |
author_facet | Günal-Abduljalil, Burcu Önöral, Özay Ongun, Salim |
author_sort | Günal-Abduljalil, Burcu |
collection | PubMed |
description | PURPOSE: This study aimed to assess the influence of various micromechanical surface conditioning (MSC) strategies with or without coupling agent (silane) application on the micro-shear bond strength (µSBS) of resin- matrix ceramics (RMCs). MATERIALS AND METHODS: GC Cerasmart (GC), Lava Ultimate (LU), Vita Enamic (VE), Voco Grandio (VG), and Brilliant Crios (BC) were cut into 1.0-mm-thick slices (n = 32 per RMC) and separated into four groups according to the MSC strategy applied: control-no conditioning (C), air-borne particle abrasion with aluminum oxide particles (APA), 2W- and 3W-Er,Cr:YSGG group coding is missing. The specimens in each group were further separated into silane-applied and silane-free subgroups. Each specimen received two resin cement microtubules (n = 8 per subgroup). A shear force was applied to the adhesive interface through a universal test machine and µSBS values were measured. Data were statistically analyzed by using 3-way ANOVA and Tukey HSD test. Failure patterns were scrutinized under stereomicroscope. RESULTS: RMC material type, MSC strategy, and silanization influenced the µSBS values (P<.05). In comparison to the control group, µSBS values increased after all other MSC strategies (P<.05) while the differences among these strategies were insignificant (P>.05). For control and APA, there were insignificant differences between RMCs (P>.05). The silanization decreased µSBS values of RMCs except for VE. Considerable declines were observed in GC and BC (P<.05). CONCLUSION: MSC strategies can enhance bond strength values at the RMC - cement interface. However, the choice of MSC strategy is dependent on RMC material type and each RMC can require a dedicated way of conditioning. |
format | Online Article Text |
id | pubmed-8250191 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-82501912021-07-06 Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application Günal-Abduljalil, Burcu Önöral, Özay Ongun, Salim J Adv Prosthodont Original Article PURPOSE: This study aimed to assess the influence of various micromechanical surface conditioning (MSC) strategies with or without coupling agent (silane) application on the micro-shear bond strength (µSBS) of resin- matrix ceramics (RMCs). MATERIALS AND METHODS: GC Cerasmart (GC), Lava Ultimate (LU), Vita Enamic (VE), Voco Grandio (VG), and Brilliant Crios (BC) were cut into 1.0-mm-thick slices (n = 32 per RMC) and separated into four groups according to the MSC strategy applied: control-no conditioning (C), air-borne particle abrasion with aluminum oxide particles (APA), 2W- and 3W-Er,Cr:YSGG group coding is missing. The specimens in each group were further separated into silane-applied and silane-free subgroups. Each specimen received two resin cement microtubules (n = 8 per subgroup). A shear force was applied to the adhesive interface through a universal test machine and µSBS values were measured. Data were statistically analyzed by using 3-way ANOVA and Tukey HSD test. Failure patterns were scrutinized under stereomicroscope. RESULTS: RMC material type, MSC strategy, and silanization influenced the µSBS values (P<.05). In comparison to the control group, µSBS values increased after all other MSC strategies (P<.05) while the differences among these strategies were insignificant (P>.05). For control and APA, there were insignificant differences between RMCs (P>.05). The silanization decreased µSBS values of RMCs except for VE. Considerable declines were observed in GC and BC (P<.05). CONCLUSION: MSC strategies can enhance bond strength values at the RMC - cement interface. However, the choice of MSC strategy is dependent on RMC material type and each RMC can require a dedicated way of conditioning. The Korean Academy of Prosthodontics 2021-06 2021-06-25 /pmc/articles/PMC8250191/ /pubmed/34234928 http://dx.doi.org/10.4047/jap.2021.13.3.180 Text en © 2021 The Korean Academy of Prosthodontics https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Günal-Abduljalil, Burcu Önöral, Özay Ongun, Salim Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application |
title | Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application |
title_full | Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application |
title_fullStr | Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application |
title_full_unstemmed | Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application |
title_short | Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application |
title_sort | micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8250191/ https://www.ncbi.nlm.nih.gov/pubmed/34234928 http://dx.doi.org/10.4047/jap.2021.13.3.180 |
work_keys_str_mv | AT gunalabduljalilburcu microshearbondstrengthsofresinmatrixceramicssubjectedtodifferentsurfaceconditioningstrategieswithorwithoutcouplingagentapplication AT onoralozay microshearbondstrengthsofresinmatrixceramicssubjectedtodifferentsurfaceconditioningstrategieswithorwithoutcouplingagentapplication AT ongunsalim microshearbondstrengthsofresinmatrixceramicssubjectedtodifferentsurfaceconditioningstrategieswithorwithoutcouplingagentapplication |