Cargando…
A Retrospective Analysis of Safety and Efficacy of XEN 45 Microstent Combined Cataract Surgery in Open-Angle Glaucoma over 24 Months
OBJECTIVES: To evaluate the effect on intraocular pressure (IOP) reduction and safety of ab interno gelatin microstent (XEN 45 Gel Stent; Aquesys, Inc, Aliso Viejo, CA, USA) microincisional glaucoma/cataract surgery in open-angle glaucoma (OAG). MATERIALS AND METHODS: In this retrospective study, 30...
Autores principales: | Subaşı, Sevgi, Yüksel, Nurşen, Özer, Fevzi, Yılmaz Tugan, Büşra, Pirhan, Dilara |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Galenos Publishing
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8251676/ https://www.ncbi.nlm.nih.gov/pubmed/34187146 http://dx.doi.org/10.4274/tjo.galenos.2020.47629 |
Ejemplares similares
-
Evaluation of macular and peripapillary vascular parameter change in healthy subjects after caffeine intake using optical coherence tomography angiography
por: Yilmaz Tugan, Busra, et al.
Publicado: (2022) -
In Vivo Confocal Microscopy Analysis of the Corneal Layers in Adenoviral Epidemic Keratoconjunctivitis
por: Subaşı, Sevgi, et al.
Publicado: (2018) -
Comparative Proteomic Analysis of the Aqueous Humor from Patients with Pseudoexfoliation Syndrome
por: Toprak, Muge, et al.
Publicado: (2023) -
Pseudoexfoliation Glaucoma: Clinical Presentation and Therapeutic Options
por: Yüksel, Nurşen, et al.
Publicado: (2023) -
Outcome of a single XEN microstent implant for glaucoma patients with different types of glaucoma
por: Schargus, Marc, et al.
Publicado: (2020)