Cargando…

Three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: Influence of segmentation factor and flow compensation

PURPOSE: To monitor the complete passage of the labeled blood through the vascular tree into tissue and improve the quantification of ASL maps, we evaluated the effect of 3D gradient and spin‐echo (GRASE) readout segments on temporal SNR (tSNR) and image blurriness for time‐encoded pseudo‐continuous...

Descripción completa

Detalles Bibliográficos
Autores principales: Paschoal, Andre M., Leoni, Renata F., Pastorello, Bruno F., van Osch, Matthias J. P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8251744/
https://www.ncbi.nlm.nih.gov/pubmed/33942371
http://dx.doi.org/10.1002/mrm.28807
_version_ 1783717153042595840
author Paschoal, Andre M.
Leoni, Renata F.
Pastorello, Bruno F.
van Osch, Matthias J. P.
author_facet Paschoal, Andre M.
Leoni, Renata F.
Pastorello, Bruno F.
van Osch, Matthias J. P.
author_sort Paschoal, Andre M.
collection PubMed
description PURPOSE: To monitor the complete passage of the labeled blood through the vascular tree into tissue and improve the quantification of ASL maps, we evaluated the effect of 3D gradient and spin‐echo (GRASE) readout segments on temporal SNR (tSNR) and image blurriness for time‐encoded pseudo‐continuous arterial spin labeling and the effect of flow‐compensation gradients on the presence of intravascular signal. METHODS: Fifteen volunteers were scanned using time‐encoded pCASL with 2D EPI and single‐segment, two‐segments, and three‐segments 3D‐GRASE readouts with first‐order flow compensation (FC) gradients. Two‐segments 3D‐GRASE scans were acquired with 25%, 50%, 75%, and 100% of full first‐order FC. Temporal SNR was assessed, and cerebral blood flow and arterial blood volume were quantified for all readout strategies. RESULTS: For single‐segment 3D GRASE, tSNR was comparable to 2D EPI for perfusion signal but worse for the arterial signal. Two‐segments and three‐segments 3D GRASE resulted in higher tSNR than 2D EPI for perfusion and arterial signal. The arterial signal was not well visualized for 3D‐GRASE data without FC. Visualization of the intravascular signal at postlabeling delays of 660 ms and 1060 ms was restored with FC. Adequate visualization of the intravascular signal was achieved from 75% of FC gradient strength at a postlabeling delay of 660 ms. For a postlabeling delay of 1060 ms, full‐FC gradients were the best option to depict intravascular signal. CONCLUSION: Segmented GRASE provided higher effective tSNR compared with 2D‐EPI and single‐segment GRASE. Flow compensation with GRASE readout should be carefully controlled when applying for time‐encoded pCASL to visualize intravascular signal.
format Online
Article
Text
id pubmed-8251744
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-82517442021-07-07 Three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: Influence of segmentation factor and flow compensation Paschoal, Andre M. Leoni, Renata F. Pastorello, Bruno F. van Osch, Matthias J. P. Magn Reson Med Technical Notes—Imaging Methodology PURPOSE: To monitor the complete passage of the labeled blood through the vascular tree into tissue and improve the quantification of ASL maps, we evaluated the effect of 3D gradient and spin‐echo (GRASE) readout segments on temporal SNR (tSNR) and image blurriness for time‐encoded pseudo‐continuous arterial spin labeling and the effect of flow‐compensation gradients on the presence of intravascular signal. METHODS: Fifteen volunteers were scanned using time‐encoded pCASL with 2D EPI and single‐segment, two‐segments, and three‐segments 3D‐GRASE readouts with first‐order flow compensation (FC) gradients. Two‐segments 3D‐GRASE scans were acquired with 25%, 50%, 75%, and 100% of full first‐order FC. Temporal SNR was assessed, and cerebral blood flow and arterial blood volume were quantified for all readout strategies. RESULTS: For single‐segment 3D GRASE, tSNR was comparable to 2D EPI for perfusion signal but worse for the arterial signal. Two‐segments and three‐segments 3D GRASE resulted in higher tSNR than 2D EPI for perfusion and arterial signal. The arterial signal was not well visualized for 3D‐GRASE data without FC. Visualization of the intravascular signal at postlabeling delays of 660 ms and 1060 ms was restored with FC. Adequate visualization of the intravascular signal was achieved from 75% of FC gradient strength at a postlabeling delay of 660 ms. For a postlabeling delay of 1060 ms, full‐FC gradients were the best option to depict intravascular signal. CONCLUSION: Segmented GRASE provided higher effective tSNR compared with 2D‐EPI and single‐segment GRASE. Flow compensation with GRASE readout should be carefully controlled when applying for time‐encoded pCASL to visualize intravascular signal. John Wiley and Sons Inc. 2021-05-04 2021-09 /pmc/articles/PMC8251744/ /pubmed/33942371 http://dx.doi.org/10.1002/mrm.28807 Text en © 2021 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Technical Notes—Imaging Methodology
Paschoal, Andre M.
Leoni, Renata F.
Pastorello, Bruno F.
van Osch, Matthias J. P.
Three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: Influence of segmentation factor and flow compensation
title Three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: Influence of segmentation factor and flow compensation
title_full Three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: Influence of segmentation factor and flow compensation
title_fullStr Three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: Influence of segmentation factor and flow compensation
title_full_unstemmed Three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: Influence of segmentation factor and flow compensation
title_short Three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: Influence of segmentation factor and flow compensation
title_sort three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: influence of segmentation factor and flow compensation
topic Technical Notes—Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8251744/
https://www.ncbi.nlm.nih.gov/pubmed/33942371
http://dx.doi.org/10.1002/mrm.28807
work_keys_str_mv AT paschoalandrem threedimensionalgradientandspinechoreadoutfortimeencodedpseudocontinuousarterialspinlabelinginfluenceofsegmentationfactorandflowcompensation
AT leonirenataf threedimensionalgradientandspinechoreadoutfortimeencodedpseudocontinuousarterialspinlabelinginfluenceofsegmentationfactorandflowcompensation
AT pastorellobrunof threedimensionalgradientandspinechoreadoutfortimeencodedpseudocontinuousarterialspinlabelinginfluenceofsegmentationfactorandflowcompensation
AT vanoschmatthiasjp threedimensionalgradientandspinechoreadoutfortimeencodedpseudocontinuousarterialspinlabelinginfluenceofsegmentationfactorandflowcompensation