Cargando…

Comparing differences and correlation between 24-hour ambulatory blood pressure and office blood pressure monitoring in patients with untreated hypertension

OBJECTIVE: We assessed differences and correlations between 24-hour ambulatory blood pressure (ABP) and office blood pressure (OBP) monitoring. METHODS: We conducted an observational study among 85 untreated patients with essential hypertension and measured 24-hour ABP, OBP, target organ damage (TOD...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Zhenhong, Wang, Shunyin, Yan, Junru, Xu, Zhiwen, Liang, Dongliang, Liu, Baohua, Liang, Junjie, Chen, Mingjie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8252350/
https://www.ncbi.nlm.nih.gov/pubmed/34187215
http://dx.doi.org/10.1177/03000605211016144
_version_ 1783717280409976832
author Zhang, Zhenhong
Wang, Shunyin
Yan, Junru
Xu, Zhiwen
Liang, Dongliang
Liu, Baohua
Liang, Junjie
Chen, Mingjie
author_facet Zhang, Zhenhong
Wang, Shunyin
Yan, Junru
Xu, Zhiwen
Liang, Dongliang
Liu, Baohua
Liang, Junjie
Chen, Mingjie
author_sort Zhang, Zhenhong
collection PubMed
description OBJECTIVE: We assessed differences and correlations between 24-hour ambulatory blood pressure (ABP) and office blood pressure (OBP) monitoring. METHODS: We conducted an observational study among 85 untreated patients with essential hypertension and measured 24-hour ABP, OBP, target organ damage (TOD) markers, and metabolism indexes. Variance analysis and the Pearson method were used to compare differences and correlation between the two methods. The Spearman or Pearson method was applied to compare the correlation between TOD markers, blood pressure index, and metabolism index. Linear regression analysis was applied to estimate the quantitative relationship between the blood pressure index and TOD markers. RESULTS: There were significant differences in the mean and variance of systolic blood pressure (SBP) and diastolic blood pressure and a positive correlation between ABP and OBP. Correlations between the left ventricular mass index (LVMI) and average ambulatory SBP, daytime ambulatory SBP, nighttime ambulatory SBP, and fasting blood glucose were significant. Correlations between left intima-media thickness (IMT) and average ambulatory SBP, nighttime ambulatory SBP, right IMT, and nighttime ambulatory SBP were significant. In linear regression analysis of the LVMI (y) and ambulatory SBP (x), the equation was expressed as y = 0.637*x. CONCLUSION: Nighttime ambulatory SBP may be an optimal predictor of TOD.
format Online
Article
Text
id pubmed-8252350
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-82523502021-07-13 Comparing differences and correlation between 24-hour ambulatory blood pressure and office blood pressure monitoring in patients with untreated hypertension Zhang, Zhenhong Wang, Shunyin Yan, Junru Xu, Zhiwen Liang, Dongliang Liu, Baohua Liang, Junjie Chen, Mingjie J Int Med Res Retrospective Clinical Research Report OBJECTIVE: We assessed differences and correlations between 24-hour ambulatory blood pressure (ABP) and office blood pressure (OBP) monitoring. METHODS: We conducted an observational study among 85 untreated patients with essential hypertension and measured 24-hour ABP, OBP, target organ damage (TOD) markers, and metabolism indexes. Variance analysis and the Pearson method were used to compare differences and correlation between the two methods. The Spearman or Pearson method was applied to compare the correlation between TOD markers, blood pressure index, and metabolism index. Linear regression analysis was applied to estimate the quantitative relationship between the blood pressure index and TOD markers. RESULTS: There were significant differences in the mean and variance of systolic blood pressure (SBP) and diastolic blood pressure and a positive correlation between ABP and OBP. Correlations between the left ventricular mass index (LVMI) and average ambulatory SBP, daytime ambulatory SBP, nighttime ambulatory SBP, and fasting blood glucose were significant. Correlations between left intima-media thickness (IMT) and average ambulatory SBP, nighttime ambulatory SBP, right IMT, and nighttime ambulatory SBP were significant. In linear regression analysis of the LVMI (y) and ambulatory SBP (x), the equation was expressed as y = 0.637*x. CONCLUSION: Nighttime ambulatory SBP may be an optimal predictor of TOD. SAGE Publications 2021-06-29 /pmc/articles/PMC8252350/ /pubmed/34187215 http://dx.doi.org/10.1177/03000605211016144 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Retrospective Clinical Research Report
Zhang, Zhenhong
Wang, Shunyin
Yan, Junru
Xu, Zhiwen
Liang, Dongliang
Liu, Baohua
Liang, Junjie
Chen, Mingjie
Comparing differences and correlation between 24-hour ambulatory blood pressure and office blood pressure monitoring in patients with untreated hypertension
title Comparing differences and correlation between 24-hour ambulatory blood pressure and office blood pressure monitoring in patients with untreated hypertension
title_full Comparing differences and correlation between 24-hour ambulatory blood pressure and office blood pressure monitoring in patients with untreated hypertension
title_fullStr Comparing differences and correlation between 24-hour ambulatory blood pressure and office blood pressure monitoring in patients with untreated hypertension
title_full_unstemmed Comparing differences and correlation between 24-hour ambulatory blood pressure and office blood pressure monitoring in patients with untreated hypertension
title_short Comparing differences and correlation between 24-hour ambulatory blood pressure and office blood pressure monitoring in patients with untreated hypertension
title_sort comparing differences and correlation between 24-hour ambulatory blood pressure and office blood pressure monitoring in patients with untreated hypertension
topic Retrospective Clinical Research Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8252350/
https://www.ncbi.nlm.nih.gov/pubmed/34187215
http://dx.doi.org/10.1177/03000605211016144
work_keys_str_mv AT zhangzhenhong comparingdifferencesandcorrelationbetween24hourambulatorybloodpressureandofficebloodpressuremonitoringinpatientswithuntreatedhypertension
AT wangshunyin comparingdifferencesandcorrelationbetween24hourambulatorybloodpressureandofficebloodpressuremonitoringinpatientswithuntreatedhypertension
AT yanjunru comparingdifferencesandcorrelationbetween24hourambulatorybloodpressureandofficebloodpressuremonitoringinpatientswithuntreatedhypertension
AT xuzhiwen comparingdifferencesandcorrelationbetween24hourambulatorybloodpressureandofficebloodpressuremonitoringinpatientswithuntreatedhypertension
AT liangdongliang comparingdifferencesandcorrelationbetween24hourambulatorybloodpressureandofficebloodpressuremonitoringinpatientswithuntreatedhypertension
AT liubaohua comparingdifferencesandcorrelationbetween24hourambulatorybloodpressureandofficebloodpressuremonitoringinpatientswithuntreatedhypertension
AT liangjunjie comparingdifferencesandcorrelationbetween24hourambulatorybloodpressureandofficebloodpressuremonitoringinpatientswithuntreatedhypertension
AT chenmingjie comparingdifferencesandcorrelationbetween24hourambulatorybloodpressureandofficebloodpressuremonitoringinpatientswithuntreatedhypertension