Cargando…
CT-Guided Transthoracic Biopsy of Lung Lesions Using a Non-Coaxial Biopsy Needle Technique: CT Characteristics Predictive for Diagnostic Accuracy and Pneumothorax
OBJECTIVES: To analyze computed tomography (CT) characteristics predictive for diagnostic accuracy and pneumothorax in CT fluoroscopy-guided transthoracic biopsy (CTF-TTB) of lung lesions using non-coaxial biopsy needle technique. METHODS: Retrospectively 274 lung lesion biopsies with confirmed hist...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Ubiquity Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8252971/ https://www.ncbi.nlm.nih.gov/pubmed/34250437 http://dx.doi.org/10.5334/jbsr.2429 |
_version_ | 1783717410564472832 |
---|---|
author | Geeroms, Barbara Cockmartin, Lesley Coolen, Johan Dubbeldam, Adriana Verschakelen, Johny Nikoghosyan, Ani De Wever, Walter |
author_facet | Geeroms, Barbara Cockmartin, Lesley Coolen, Johan Dubbeldam, Adriana Verschakelen, Johny Nikoghosyan, Ani De Wever, Walter |
author_sort | Geeroms, Barbara |
collection | PubMed |
description | OBJECTIVES: To analyze computed tomography (CT) characteristics predictive for diagnostic accuracy and pneumothorax in CT fluoroscopy-guided transthoracic biopsy (CTF-TTB) of lung lesions using non-coaxial biopsy needle technique. METHODS: Retrospectively 274 lung lesion biopsies with confirmed histology were included in our study. CTF-TTB was done using an 18-gauge non-coaxial cutting needle. Diagnostic accuracy rates were calculated per lesion size and CT and procedural characteristics were evaluated for their predictive value regarding diagnostic accuracy and development of pneumothorax (maximal nodule diameter, distance to pleura, location per lung segment, nodule composition, benign versus malignant histology, and number of specimens). RESULTS: Overall diagnostic accuracy of CTF-TTB was high (93%). Diagnostic accuracy for lesions ≤10 mm was 81%. Maximal nodule diameter was the only predictive CT characteristic for diagnostic success (p = 0.03). Pneumothorax occurred in 27%. Distance of lesion to pleura was the only risk factor for pneumothorax (p < 0.00001). Pneumothorax rates were significantly lower in subpleural lesions (14%) compared to those located 1–10 mm (47%), 10–20 mm (33%), and >20 mm from pleura (29%). CONCLUSIONS: High diagnostic accuracy rates were achieved with CTF-TTB using non-coaxial biopsy technique, even for lesions ≤10 mm. Pneumothorax rates were comparable with other studies. Lesion size was the only predictive CT characteristic for diagnostic accuracy. Distance to pleura was the only risk factor for pneumothorax. |
format | Online Article Text |
id | pubmed-8252971 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Ubiquity Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-82529712021-07-08 CT-Guided Transthoracic Biopsy of Lung Lesions Using a Non-Coaxial Biopsy Needle Technique: CT Characteristics Predictive for Diagnostic Accuracy and Pneumothorax Geeroms, Barbara Cockmartin, Lesley Coolen, Johan Dubbeldam, Adriana Verschakelen, Johny Nikoghosyan, Ani De Wever, Walter J Belg Soc Radiol Original Article OBJECTIVES: To analyze computed tomography (CT) characteristics predictive for diagnostic accuracy and pneumothorax in CT fluoroscopy-guided transthoracic biopsy (CTF-TTB) of lung lesions using non-coaxial biopsy needle technique. METHODS: Retrospectively 274 lung lesion biopsies with confirmed histology were included in our study. CTF-TTB was done using an 18-gauge non-coaxial cutting needle. Diagnostic accuracy rates were calculated per lesion size and CT and procedural characteristics were evaluated for their predictive value regarding diagnostic accuracy and development of pneumothorax (maximal nodule diameter, distance to pleura, location per lung segment, nodule composition, benign versus malignant histology, and number of specimens). RESULTS: Overall diagnostic accuracy of CTF-TTB was high (93%). Diagnostic accuracy for lesions ≤10 mm was 81%. Maximal nodule diameter was the only predictive CT characteristic for diagnostic success (p = 0.03). Pneumothorax occurred in 27%. Distance of lesion to pleura was the only risk factor for pneumothorax (p < 0.00001). Pneumothorax rates were significantly lower in subpleural lesions (14%) compared to those located 1–10 mm (47%), 10–20 mm (33%), and >20 mm from pleura (29%). CONCLUSIONS: High diagnostic accuracy rates were achieved with CTF-TTB using non-coaxial biopsy technique, even for lesions ≤10 mm. Pneumothorax rates were comparable with other studies. Lesion size was the only predictive CT characteristic for diagnostic accuracy. Distance to pleura was the only risk factor for pneumothorax. Ubiquity Press 2021-06-30 /pmc/articles/PMC8252971/ /pubmed/34250437 http://dx.doi.org/10.5334/jbsr.2429 Text en Copyright: © 2021 The Author(s) https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC-BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. See http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Original Article Geeroms, Barbara Cockmartin, Lesley Coolen, Johan Dubbeldam, Adriana Verschakelen, Johny Nikoghosyan, Ani De Wever, Walter CT-Guided Transthoracic Biopsy of Lung Lesions Using a Non-Coaxial Biopsy Needle Technique: CT Characteristics Predictive for Diagnostic Accuracy and Pneumothorax |
title | CT-Guided Transthoracic Biopsy of Lung Lesions Using a Non-Coaxial Biopsy Needle Technique: CT Characteristics Predictive for Diagnostic Accuracy and Pneumothorax |
title_full | CT-Guided Transthoracic Biopsy of Lung Lesions Using a Non-Coaxial Biopsy Needle Technique: CT Characteristics Predictive for Diagnostic Accuracy and Pneumothorax |
title_fullStr | CT-Guided Transthoracic Biopsy of Lung Lesions Using a Non-Coaxial Biopsy Needle Technique: CT Characteristics Predictive for Diagnostic Accuracy and Pneumothorax |
title_full_unstemmed | CT-Guided Transthoracic Biopsy of Lung Lesions Using a Non-Coaxial Biopsy Needle Technique: CT Characteristics Predictive for Diagnostic Accuracy and Pneumothorax |
title_short | CT-Guided Transthoracic Biopsy of Lung Lesions Using a Non-Coaxial Biopsy Needle Technique: CT Characteristics Predictive for Diagnostic Accuracy and Pneumothorax |
title_sort | ct-guided transthoracic biopsy of lung lesions using a non-coaxial biopsy needle technique: ct characteristics predictive for diagnostic accuracy and pneumothorax |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8252971/ https://www.ncbi.nlm.nih.gov/pubmed/34250437 http://dx.doi.org/10.5334/jbsr.2429 |
work_keys_str_mv | AT geeromsbarbara ctguidedtransthoracicbiopsyoflunglesionsusinganoncoaxialbiopsyneedletechniquectcharacteristicspredictivefordiagnosticaccuracyandpneumothorax AT cockmartinlesley ctguidedtransthoracicbiopsyoflunglesionsusinganoncoaxialbiopsyneedletechniquectcharacteristicspredictivefordiagnosticaccuracyandpneumothorax AT coolenjohan ctguidedtransthoracicbiopsyoflunglesionsusinganoncoaxialbiopsyneedletechniquectcharacteristicspredictivefordiagnosticaccuracyandpneumothorax AT dubbeldamadriana ctguidedtransthoracicbiopsyoflunglesionsusinganoncoaxialbiopsyneedletechniquectcharacteristicspredictivefordiagnosticaccuracyandpneumothorax AT verschakelenjohny ctguidedtransthoracicbiopsyoflunglesionsusinganoncoaxialbiopsyneedletechniquectcharacteristicspredictivefordiagnosticaccuracyandpneumothorax AT nikoghosyanani ctguidedtransthoracicbiopsyoflunglesionsusinganoncoaxialbiopsyneedletechniquectcharacteristicspredictivefordiagnosticaccuracyandpneumothorax AT deweverwalter ctguidedtransthoracicbiopsyoflunglesionsusinganoncoaxialbiopsyneedletechniquectcharacteristicspredictivefordiagnosticaccuracyandpneumothorax |