Safety and data quality of EEG recorded simultaneously with multi-band fMRI
PURPOSE: Simultaneously recorded electroencephalography and functional magnetic resonance imaging (EEG-fMRI) is highly informative yet technically challenging. Until recently, there has been little information about EEG data quality and safety when used with newer multi-band (MB) fMRI sequences. Her...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8253410/ https://www.ncbi.nlm.nih.gov/pubmed/34214093 http://dx.doi.org/10.1371/journal.pone.0238485 |
_version_ | 1783717505930362880 |
---|---|
author | Egan, Maximillian K. Larsen, Ryan Wirsich, Jonathan Sutton, Brad P. Sadaghiani, Sepideh |
author_facet | Egan, Maximillian K. Larsen, Ryan Wirsich, Jonathan Sutton, Brad P. Sadaghiani, Sepideh |
author_sort | Egan, Maximillian K. |
collection | PubMed |
description | PURPOSE: Simultaneously recorded electroencephalography and functional magnetic resonance imaging (EEG-fMRI) is highly informative yet technically challenging. Until recently, there has been little information about EEG data quality and safety when used with newer multi-band (MB) fMRI sequences. Here, we measure the relative heating of a MB protocol compared with a standard single-band (SB) protocol considered to be safe. We also evaluated EEG quality recorded concurrently with the MB protocol on humans. MATERIALS AND METHODS: We compared radiofrequency (RF)-related heating at multiple electrodes and magnetic field magnitude, B(1+RMS), of a MB fMRI sequence with whole-brain coverage (TR = 440 ms, MB factor = 4) against a previously recommended, safe SB sequence using a phantom outfitted with a 64-channel EEG cap. Next, 9 human subjects underwent eyes-closed resting state EEG-fMRI using the MB sequence. Additionally, in three of the subjects resting state EEG was recorded also during the SB sequence and in an fMRI-free condition to directly compare EEG data quality across scanning conditions. EEG data quality was assessed by the ability to remove gradient and cardioballistic artifacts along with a clean spectrogram. RESULTS: The heating induced by the MB sequence was lower than that of the SB sequence by a factor of 0.73 ± 0.38. This is consistent with an expected heating ratio of 0.64, calculated from the square of the ratio of B(1+RMS) values of the sequences. In the resting state EEG data, gradient and cardioballistic artifacts were successfully removed using traditional template subtraction. All subjects showed an individual alpha peak in the spectrogram with a posterior topography characteristic of eyes-closed EEG. The success of artifact rejection for the MB sequence was comparable to that in traditional SB sequences. CONCLUSIONS: Our study shows that B(1+RMS) is a useful indication of the relative heating of fMRI protocols. This observation indicates that simultaneous EEG-fMRI recordings using this MB sequence can be safe in terms of RF-related heating, and that EEG data recorded using this sequence is of acceptable quality after traditional artifact removal techniques. |
format | Online Article Text |
id | pubmed-8253410 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-82534102021-07-13 Safety and data quality of EEG recorded simultaneously with multi-band fMRI Egan, Maximillian K. Larsen, Ryan Wirsich, Jonathan Sutton, Brad P. Sadaghiani, Sepideh PLoS One Research Article PURPOSE: Simultaneously recorded electroencephalography and functional magnetic resonance imaging (EEG-fMRI) is highly informative yet technically challenging. Until recently, there has been little information about EEG data quality and safety when used with newer multi-band (MB) fMRI sequences. Here, we measure the relative heating of a MB protocol compared with a standard single-band (SB) protocol considered to be safe. We also evaluated EEG quality recorded concurrently with the MB protocol on humans. MATERIALS AND METHODS: We compared radiofrequency (RF)-related heating at multiple electrodes and magnetic field magnitude, B(1+RMS), of a MB fMRI sequence with whole-brain coverage (TR = 440 ms, MB factor = 4) against a previously recommended, safe SB sequence using a phantom outfitted with a 64-channel EEG cap. Next, 9 human subjects underwent eyes-closed resting state EEG-fMRI using the MB sequence. Additionally, in three of the subjects resting state EEG was recorded also during the SB sequence and in an fMRI-free condition to directly compare EEG data quality across scanning conditions. EEG data quality was assessed by the ability to remove gradient and cardioballistic artifacts along with a clean spectrogram. RESULTS: The heating induced by the MB sequence was lower than that of the SB sequence by a factor of 0.73 ± 0.38. This is consistent with an expected heating ratio of 0.64, calculated from the square of the ratio of B(1+RMS) values of the sequences. In the resting state EEG data, gradient and cardioballistic artifacts were successfully removed using traditional template subtraction. All subjects showed an individual alpha peak in the spectrogram with a posterior topography characteristic of eyes-closed EEG. The success of artifact rejection for the MB sequence was comparable to that in traditional SB sequences. CONCLUSIONS: Our study shows that B(1+RMS) is a useful indication of the relative heating of fMRI protocols. This observation indicates that simultaneous EEG-fMRI recordings using this MB sequence can be safe in terms of RF-related heating, and that EEG data recorded using this sequence is of acceptable quality after traditional artifact removal techniques. Public Library of Science 2021-07-02 /pmc/articles/PMC8253410/ /pubmed/34214093 http://dx.doi.org/10.1371/journal.pone.0238485 Text en © 2021 Egan et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Egan, Maximillian K. Larsen, Ryan Wirsich, Jonathan Sutton, Brad P. Sadaghiani, Sepideh Safety and data quality of EEG recorded simultaneously with multi-band fMRI |
title | Safety and data quality of EEG recorded simultaneously with multi-band fMRI |
title_full | Safety and data quality of EEG recorded simultaneously with multi-band fMRI |
title_fullStr | Safety and data quality of EEG recorded simultaneously with multi-band fMRI |
title_full_unstemmed | Safety and data quality of EEG recorded simultaneously with multi-band fMRI |
title_short | Safety and data quality of EEG recorded simultaneously with multi-band fMRI |
title_sort | safety and data quality of eeg recorded simultaneously with multi-band fmri |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8253410/ https://www.ncbi.nlm.nih.gov/pubmed/34214093 http://dx.doi.org/10.1371/journal.pone.0238485 |
work_keys_str_mv | AT eganmaximilliank safetyanddataqualityofeegrecordedsimultaneouslywithmultibandfmri AT larsenryan safetyanddataqualityofeegrecordedsimultaneouslywithmultibandfmri AT wirsichjonathan safetyanddataqualityofeegrecordedsimultaneouslywithmultibandfmri AT suttonbradp safetyanddataqualityofeegrecordedsimultaneouslywithmultibandfmri AT sadaghianisepideh safetyanddataqualityofeegrecordedsimultaneouslywithmultibandfmri |