Metallosis in Sequelae of Prosthetic Revision for Ceramic Components Fracture: A Case Report with Clinical Presentation Mimicking Periprosthetic Hip Infection

Ceramic on ceramic total hip arthroplasties have been developed and widely used during last decades because of their long-term survival and biomechanical properties. One of the most dangerous complication of these implants is the fracture of the ceramic components. The management of this condition s...

Descripción completa

Detalles Bibliográficos
Autores principales: Artiaco, Stefano, Fusini, Federico, Zoccola, Kristijan, Massè, Alessandro, Colzani, Giulia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Georg Thieme Verlag KG 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8253606/
https://www.ncbi.nlm.nih.gov/pubmed/34235388
http://dx.doi.org/10.1055/s-0041-1730981
_version_ 1783717547149885440
author Artiaco, Stefano
Fusini, Federico
Zoccola, Kristijan
Massè, Alessandro
Colzani, Giulia
author_facet Artiaco, Stefano
Fusini, Federico
Zoccola, Kristijan
Massè, Alessandro
Colzani, Giulia
author_sort Artiaco, Stefano
collection PubMed
description Ceramic on ceramic total hip arthroplasties have been developed and widely used during last decades because of their long-term survival and biomechanical properties. One of the most dangerous complication of these implants is the fracture of the ceramic components. The management of this condition should be carefully planned and the choice of the new implant is crucial. We describe a rare case of severe hip synovitis due to massive metallosis in sequelae of mismanaged prosthetic revision for fracture of the ceramic acetabular liner with an unusual clinical presentation that simulate a periprosthetic infection.
format Online
Article
Text
id pubmed-8253606
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-82536062021-07-06 Metallosis in Sequelae of Prosthetic Revision for Ceramic Components Fracture: A Case Report with Clinical Presentation Mimicking Periprosthetic Hip Infection Artiaco, Stefano Fusini, Federico Zoccola, Kristijan Massè, Alessandro Colzani, Giulia Joints Ceramic on ceramic total hip arthroplasties have been developed and widely used during last decades because of their long-term survival and biomechanical properties. One of the most dangerous complication of these implants is the fracture of the ceramic components. The management of this condition should be carefully planned and the choice of the new implant is crucial. We describe a rare case of severe hip synovitis due to massive metallosis in sequelae of mismanaged prosthetic revision for fracture of the ceramic acetabular liner with an unusual clinical presentation that simulate a periprosthetic infection. Georg Thieme Verlag KG 2021-06-18 /pmc/articles/PMC8253606/ /pubmed/34235388 http://dx.doi.org/10.1055/s-0041-1730981 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ). https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Artiaco, Stefano
Fusini, Federico
Zoccola, Kristijan
Massè, Alessandro
Colzani, Giulia
Metallosis in Sequelae of Prosthetic Revision for Ceramic Components Fracture: A Case Report with Clinical Presentation Mimicking Periprosthetic Hip Infection
title Metallosis in Sequelae of Prosthetic Revision for Ceramic Components Fracture: A Case Report with Clinical Presentation Mimicking Periprosthetic Hip Infection
title_full Metallosis in Sequelae of Prosthetic Revision for Ceramic Components Fracture: A Case Report with Clinical Presentation Mimicking Periprosthetic Hip Infection
title_fullStr Metallosis in Sequelae of Prosthetic Revision for Ceramic Components Fracture: A Case Report with Clinical Presentation Mimicking Periprosthetic Hip Infection
title_full_unstemmed Metallosis in Sequelae of Prosthetic Revision for Ceramic Components Fracture: A Case Report with Clinical Presentation Mimicking Periprosthetic Hip Infection
title_short Metallosis in Sequelae of Prosthetic Revision for Ceramic Components Fracture: A Case Report with Clinical Presentation Mimicking Periprosthetic Hip Infection
title_sort metallosis in sequelae of prosthetic revision for ceramic components fracture: a case report with clinical presentation mimicking periprosthetic hip infection
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8253606/
https://www.ncbi.nlm.nih.gov/pubmed/34235388
http://dx.doi.org/10.1055/s-0041-1730981
work_keys_str_mv AT artiacostefano metallosisinsequelaeofprostheticrevisionforceramiccomponentsfractureacasereportwithclinicalpresentationmimickingperiprosthetichipinfection
AT fusinifederico metallosisinsequelaeofprostheticrevisionforceramiccomponentsfractureacasereportwithclinicalpresentationmimickingperiprosthetichipinfection
AT zoccolakristijan metallosisinsequelaeofprostheticrevisionforceramiccomponentsfractureacasereportwithclinicalpresentationmimickingperiprosthetichipinfection
AT massealessandro metallosisinsequelaeofprostheticrevisionforceramiccomponentsfractureacasereportwithclinicalpresentationmimickingperiprosthetichipinfection
AT colzanigiulia metallosisinsequelaeofprostheticrevisionforceramiccomponentsfractureacasereportwithclinicalpresentationmimickingperiprosthetichipinfection