Cargando…

Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting

Surgical fixation of comminuted patella fractures is technically challenging. Despite the fact that tension band wiring or screw fixation are the most common surgical procedures, these surgical techniques have crucial limitations for laterally scattered fragments. We demonstrate two cases with commi...

Descripción completa

Detalles Bibliográficos
Autores principales: Kizaki, Kazuha, Uchida, Soshi, Funakoshi, Noboru, Mori, Daisuke, Nakai, Ryosuke, Yamashita, Fumiharu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Georg Thieme Verlag KG 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8253615/
https://www.ncbi.nlm.nih.gov/pubmed/34235389
http://dx.doi.org/10.1055/s-0041-1730379
_version_ 1783717549285834752
author Kizaki, Kazuha
Uchida, Soshi
Funakoshi, Noboru
Mori, Daisuke
Nakai, Ryosuke
Yamashita, Fumiharu
author_facet Kizaki, Kazuha
Uchida, Soshi
Funakoshi, Noboru
Mori, Daisuke
Nakai, Ryosuke
Yamashita, Fumiharu
author_sort Kizaki, Kazuha
collection PubMed
description Surgical fixation of comminuted patella fractures is technically challenging. Despite the fact that tension band wiring or screw fixation are the most common surgical procedures, these surgical techniques have crucial limitations for laterally scattered fragments. We demonstrate two cases with comminuted patella fractures undergoing surgical fixation with self-locking pin and circumferential wiring, confirming the rigid fixation achieving deep knee flexion. After midline longitudinal skin incision, 2.0 mm stainless pins (AiMedic MMT, Tokyo, Japan) were inserted radially to penetrate each fragment and 1.2 mm stainless wire was circumferentially looped and self-locked in the holes on the pins, which satisfied rigid fixation. Any restrictions in range of motion and weight bearing were required postoperatively and 3- to 6-month postoperative cares achieved seiza-style sitting with deep knee flexion.
format Online
Article
Text
id pubmed-8253615
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-82536152021-07-06 Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting Kizaki, Kazuha Uchida, Soshi Funakoshi, Noboru Mori, Daisuke Nakai, Ryosuke Yamashita, Fumiharu Joints Surgical fixation of comminuted patella fractures is technically challenging. Despite the fact that tension band wiring or screw fixation are the most common surgical procedures, these surgical techniques have crucial limitations for laterally scattered fragments. We demonstrate two cases with comminuted patella fractures undergoing surgical fixation with self-locking pin and circumferential wiring, confirming the rigid fixation achieving deep knee flexion. After midline longitudinal skin incision, 2.0 mm stainless pins (AiMedic MMT, Tokyo, Japan) were inserted radially to penetrate each fragment and 1.2 mm stainless wire was circumferentially looped and self-locked in the holes on the pins, which satisfied rigid fixation. Any restrictions in range of motion and weight bearing were required postoperatively and 3- to 6-month postoperative cares achieved seiza-style sitting with deep knee flexion. Georg Thieme Verlag KG 2021-06-18 /pmc/articles/PMC8253615/ /pubmed/34235389 http://dx.doi.org/10.1055/s-0041-1730379 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ). https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Kizaki, Kazuha
Uchida, Soshi
Funakoshi, Noboru
Mori, Daisuke
Nakai, Ryosuke
Yamashita, Fumiharu
Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting
title Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting
title_full Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting
title_fullStr Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting
title_full_unstemmed Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting
title_short Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting
title_sort surgical management with self-locking pins and circumferential wiring for treating comminuted patella fractures achieved seiza-style sitting
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8253615/
https://www.ncbi.nlm.nih.gov/pubmed/34235389
http://dx.doi.org/10.1055/s-0041-1730379
work_keys_str_mv AT kizakikazuha surgicalmanagementwithselflockingpinsandcircumferentialwiringfortreatingcomminutedpatellafracturesachievedseizastylesitting
AT uchidasoshi surgicalmanagementwithselflockingpinsandcircumferentialwiringfortreatingcomminutedpatellafracturesachievedseizastylesitting
AT funakoshinoboru surgicalmanagementwithselflockingpinsandcircumferentialwiringfortreatingcomminutedpatellafracturesachievedseizastylesitting
AT moridaisuke surgicalmanagementwithselflockingpinsandcircumferentialwiringfortreatingcomminutedpatellafracturesachievedseizastylesitting
AT nakairyosuke surgicalmanagementwithselflockingpinsandcircumferentialwiringfortreatingcomminutedpatellafracturesachievedseizastylesitting
AT yamashitafumiharu surgicalmanagementwithselflockingpinsandcircumferentialwiringfortreatingcomminutedpatellafracturesachievedseizastylesitting