Cargando…
Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting
Surgical fixation of comminuted patella fractures is technically challenging. Despite the fact that tension band wiring or screw fixation are the most common surgical procedures, these surgical techniques have crucial limitations for laterally scattered fragments. We demonstrate two cases with commi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Georg Thieme Verlag KG
2021
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8253615/ https://www.ncbi.nlm.nih.gov/pubmed/34235389 http://dx.doi.org/10.1055/s-0041-1730379 |
_version_ | 1783717549285834752 |
---|---|
author | Kizaki, Kazuha Uchida, Soshi Funakoshi, Noboru Mori, Daisuke Nakai, Ryosuke Yamashita, Fumiharu |
author_facet | Kizaki, Kazuha Uchida, Soshi Funakoshi, Noboru Mori, Daisuke Nakai, Ryosuke Yamashita, Fumiharu |
author_sort | Kizaki, Kazuha |
collection | PubMed |
description | Surgical fixation of comminuted patella fractures is technically challenging. Despite the fact that tension band wiring or screw fixation are the most common surgical procedures, these surgical techniques have crucial limitations for laterally scattered fragments. We demonstrate two cases with comminuted patella fractures undergoing surgical fixation with self-locking pin and circumferential wiring, confirming the rigid fixation achieving deep knee flexion. After midline longitudinal skin incision, 2.0 mm stainless pins (AiMedic MMT, Tokyo, Japan) were inserted radially to penetrate each fragment and 1.2 mm stainless wire was circumferentially looped and self-locked in the holes on the pins, which satisfied rigid fixation. Any restrictions in range of motion and weight bearing were required postoperatively and 3- to 6-month postoperative cares achieved seiza-style sitting with deep knee flexion. |
format | Online Article Text |
id | pubmed-8253615 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-82536152021-07-06 Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting Kizaki, Kazuha Uchida, Soshi Funakoshi, Noboru Mori, Daisuke Nakai, Ryosuke Yamashita, Fumiharu Joints Surgical fixation of comminuted patella fractures is technically challenging. Despite the fact that tension band wiring or screw fixation are the most common surgical procedures, these surgical techniques have crucial limitations for laterally scattered fragments. We demonstrate two cases with comminuted patella fractures undergoing surgical fixation with self-locking pin and circumferential wiring, confirming the rigid fixation achieving deep knee flexion. After midline longitudinal skin incision, 2.0 mm stainless pins (AiMedic MMT, Tokyo, Japan) were inserted radially to penetrate each fragment and 1.2 mm stainless wire was circumferentially looped and self-locked in the holes on the pins, which satisfied rigid fixation. Any restrictions in range of motion and weight bearing were required postoperatively and 3- to 6-month postoperative cares achieved seiza-style sitting with deep knee flexion. Georg Thieme Verlag KG 2021-06-18 /pmc/articles/PMC8253615/ /pubmed/34235389 http://dx.doi.org/10.1055/s-0041-1730379 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ). https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | Kizaki, Kazuha Uchida, Soshi Funakoshi, Noboru Mori, Daisuke Nakai, Ryosuke Yamashita, Fumiharu Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting |
title | Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting |
title_full | Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting |
title_fullStr | Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting |
title_full_unstemmed | Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting |
title_short | Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting |
title_sort | surgical management with self-locking pins and circumferential wiring for treating comminuted patella fractures achieved seiza-style sitting |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8253615/ https://www.ncbi.nlm.nih.gov/pubmed/34235389 http://dx.doi.org/10.1055/s-0041-1730379 |
work_keys_str_mv | AT kizakikazuha surgicalmanagementwithselflockingpinsandcircumferentialwiringfortreatingcomminutedpatellafracturesachievedseizastylesitting AT uchidasoshi surgicalmanagementwithselflockingpinsandcircumferentialwiringfortreatingcomminutedpatellafracturesachievedseizastylesitting AT funakoshinoboru surgicalmanagementwithselflockingpinsandcircumferentialwiringfortreatingcomminutedpatellafracturesachievedseizastylesitting AT moridaisuke surgicalmanagementwithselflockingpinsandcircumferentialwiringfortreatingcomminutedpatellafracturesachievedseizastylesitting AT nakairyosuke surgicalmanagementwithselflockingpinsandcircumferentialwiringfortreatingcomminutedpatellafracturesachievedseizastylesitting AT yamashitafumiharu surgicalmanagementwithselflockingpinsandcircumferentialwiringfortreatingcomminutedpatellafracturesachievedseizastylesitting |