Correction of complex three-dimensional deformities at the proximal femur using indirect reduction with angle blade plate and patient-specific instruments: a technical note
BACKGROUND: Corrective osteotomies for complex proximal femoral deformities can be challenging; wherefore, subsidies in preoperative planning and during surgical procedures are considered helpful. Three-dimensional (3D) planning and patient-specific instruments (PSI) are already established in diffe...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8254345/ https://www.ncbi.nlm.nih.gov/pubmed/34217344 http://dx.doi.org/10.1186/s13018-021-02579-z |
_version_ | 1783717710606106624 |
---|---|
author | Jud, Lukas Vlachopoulos, Lazaros Grob, Karl |
author_facet | Jud, Lukas Vlachopoulos, Lazaros Grob, Karl |
author_sort | Jud, Lukas |
collection | PubMed |
description | BACKGROUND: Corrective osteotomies for complex proximal femoral deformities can be challenging; wherefore, subsidies in preoperative planning and during surgical procedures are considered helpful. Three-dimensional (3D) planning and patient-specific instruments (PSI) are already established in different orthopedic procedures. This study gives an overview on this technique at the proximal femur and proposes a new indirect reduction technique using an angle blade plate. METHODS: Using computed tomography (CT) data, 3D models are generated serving for the preoperative 3D planning. Different guides are used for registration of the planning to the intraoperative situation and to perform the desired osteotomies with the following reduction task. A new valuable tool to perform the correction is the use of a combined osteotomy and implant-positioning guide, with indirect deformity reduction over an angle blade plate. RESULTS: An overview of the advantages of 3D planning and the use of PSI in complex corrective osteotomies at the proximal femur is provided. Furthermore, a new technique with indirect deformity reduction over an angle blade plate is introduced. CONCLUSION: Using 3D planning and PSI for complex corrective osteotomies at the proximal femur can be a useful tool in understanding the individual deformity and performing the aimed deformity reduction. The indirect reduction over the implant is a simple and valuable tool in achieving the desired correction, and concurrently, surgical exposure can be limited to a subvastus approach. |
format | Online Article Text |
id | pubmed-8254345 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-82543452021-07-06 Correction of complex three-dimensional deformities at the proximal femur using indirect reduction with angle blade plate and patient-specific instruments: a technical note Jud, Lukas Vlachopoulos, Lazaros Grob, Karl J Orthop Surg Res Technical Note BACKGROUND: Corrective osteotomies for complex proximal femoral deformities can be challenging; wherefore, subsidies in preoperative planning and during surgical procedures are considered helpful. Three-dimensional (3D) planning and patient-specific instruments (PSI) are already established in different orthopedic procedures. This study gives an overview on this technique at the proximal femur and proposes a new indirect reduction technique using an angle blade plate. METHODS: Using computed tomography (CT) data, 3D models are generated serving for the preoperative 3D planning. Different guides are used for registration of the planning to the intraoperative situation and to perform the desired osteotomies with the following reduction task. A new valuable tool to perform the correction is the use of a combined osteotomy and implant-positioning guide, with indirect deformity reduction over an angle blade plate. RESULTS: An overview of the advantages of 3D planning and the use of PSI in complex corrective osteotomies at the proximal femur is provided. Furthermore, a new technique with indirect deformity reduction over an angle blade plate is introduced. CONCLUSION: Using 3D planning and PSI for complex corrective osteotomies at the proximal femur can be a useful tool in understanding the individual deformity and performing the aimed deformity reduction. The indirect reduction over the implant is a simple and valuable tool in achieving the desired correction, and concurrently, surgical exposure can be limited to a subvastus approach. BioMed Central 2021-07-03 /pmc/articles/PMC8254345/ /pubmed/34217344 http://dx.doi.org/10.1186/s13018-021-02579-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Technical Note Jud, Lukas Vlachopoulos, Lazaros Grob, Karl Correction of complex three-dimensional deformities at the proximal femur using indirect reduction with angle blade plate and patient-specific instruments: a technical note |
title | Correction of complex three-dimensional deformities at the proximal femur using indirect reduction with angle blade plate and patient-specific instruments: a technical note |
title_full | Correction of complex three-dimensional deformities at the proximal femur using indirect reduction with angle blade plate and patient-specific instruments: a technical note |
title_fullStr | Correction of complex three-dimensional deformities at the proximal femur using indirect reduction with angle blade plate and patient-specific instruments: a technical note |
title_full_unstemmed | Correction of complex three-dimensional deformities at the proximal femur using indirect reduction with angle blade plate and patient-specific instruments: a technical note |
title_short | Correction of complex three-dimensional deformities at the proximal femur using indirect reduction with angle blade plate and patient-specific instruments: a technical note |
title_sort | correction of complex three-dimensional deformities at the proximal femur using indirect reduction with angle blade plate and patient-specific instruments: a technical note |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8254345/ https://www.ncbi.nlm.nih.gov/pubmed/34217344 http://dx.doi.org/10.1186/s13018-021-02579-z |
work_keys_str_mv | AT judlukas correctionofcomplexthreedimensionaldeformitiesattheproximalfemurusingindirectreductionwithanglebladeplateandpatientspecificinstrumentsatechnicalnote AT vlachopouloslazaros correctionofcomplexthreedimensionaldeformitiesattheproximalfemurusingindirectreductionwithanglebladeplateandpatientspecificinstrumentsatechnicalnote AT grobkarl correctionofcomplexthreedimensionaldeformitiesattheproximalfemurusingindirectreductionwithanglebladeplateandpatientspecificinstrumentsatechnicalnote |