Cargando…
Diagnostic accuracy of AS-OCT vs gonioscopy for detecting angle closure: a systematic review and meta-analysis
PURPOSE: This study aims to review the literature that compares the accuracy of Anterior Segment-Optical Coherence Tomography (AS-OCT) against gonioscopy in detecting eyes with angle closure. It is currently unclear how AS-OCT fits into clinical practice for detecting angle closure. This is a system...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8255337/ https://www.ncbi.nlm.nih.gov/pubmed/34223989 http://dx.doi.org/10.1007/s00417-021-05271-4 |
_version_ | 1783717881788235776 |
---|---|
author | Desmond, Thomas Tran, Vincent Maharaj, Monish Carnt, Nicole White, Andrew |
author_facet | Desmond, Thomas Tran, Vincent Maharaj, Monish Carnt, Nicole White, Andrew |
author_sort | Desmond, Thomas |
collection | PubMed |
description | PURPOSE: This study aims to review the literature that compares the accuracy of Anterior Segment-Optical Coherence Tomography (AS-OCT) against gonioscopy in detecting eyes with angle closure. It is currently unclear how AS-OCT fits into clinical practice for detecting angle closure. This is a systematic review and meta-analysis. METHODS: A literature search was performed on Medline, Embase, Scopus and the Cochrane Central Register of Controlled Trials to identify studies that investigated the diagnostic accuracy of AS-OCT in detecting eyes with angle closure as diagnosed by gonioscopy. Eligible studies included in the analysis met stringent inclusion criteria determining the sensitivity and specificity of AS-OCT. RESULTS: The initial search identified 727 studies, of which 23 were included in the final analysis. We found substantial variation in the parameters being studied and methodologies. The sensitivity of AS-OCT ranged from 46 to 100% (median 87%). Twenty-one studies identified parameters that showed sensitivity above 80%. The specificity ranged from 55.3 to 100% (median 84%). CONCLUSION: AS-OCT demonstrates good sensitivity for detecting angle closure. It may provide an avenue to address high rates of undiagnosed angle closure, such as found in developing Asian countries. However, AS-OCT is not yet able to replace gonioscopy. Clinicians should consider whether the diagnostic accuracy of AS-OCT is acceptable for their specific clinical use before adopting it. More studies are needed to determine the utility of AS-OCT, including longitudinal studies to determine the significance of eyes classified to have closed angles by AS-OCT but open on gonioscopy. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00417-021-05271-4. |
format | Online Article Text |
id | pubmed-8255337 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-82553372021-07-06 Diagnostic accuracy of AS-OCT vs gonioscopy for detecting angle closure: a systematic review and meta-analysis Desmond, Thomas Tran, Vincent Maharaj, Monish Carnt, Nicole White, Andrew Graefes Arch Clin Exp Ophthalmol Review Article PURPOSE: This study aims to review the literature that compares the accuracy of Anterior Segment-Optical Coherence Tomography (AS-OCT) against gonioscopy in detecting eyes with angle closure. It is currently unclear how AS-OCT fits into clinical practice for detecting angle closure. This is a systematic review and meta-analysis. METHODS: A literature search was performed on Medline, Embase, Scopus and the Cochrane Central Register of Controlled Trials to identify studies that investigated the diagnostic accuracy of AS-OCT in detecting eyes with angle closure as diagnosed by gonioscopy. Eligible studies included in the analysis met stringent inclusion criteria determining the sensitivity and specificity of AS-OCT. RESULTS: The initial search identified 727 studies, of which 23 were included in the final analysis. We found substantial variation in the parameters being studied and methodologies. The sensitivity of AS-OCT ranged from 46 to 100% (median 87%). Twenty-one studies identified parameters that showed sensitivity above 80%. The specificity ranged from 55.3 to 100% (median 84%). CONCLUSION: AS-OCT demonstrates good sensitivity for detecting angle closure. It may provide an avenue to address high rates of undiagnosed angle closure, such as found in developing Asian countries. However, AS-OCT is not yet able to replace gonioscopy. Clinicians should consider whether the diagnostic accuracy of AS-OCT is acceptable for their specific clinical use before adopting it. More studies are needed to determine the utility of AS-OCT, including longitudinal studies to determine the significance of eyes classified to have closed angles by AS-OCT but open on gonioscopy. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00417-021-05271-4. Springer Berlin Heidelberg 2021-07-05 2022 /pmc/articles/PMC8255337/ /pubmed/34223989 http://dx.doi.org/10.1007/s00417-021-05271-4 Text en © The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2021 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Review Article Desmond, Thomas Tran, Vincent Maharaj, Monish Carnt, Nicole White, Andrew Diagnostic accuracy of AS-OCT vs gonioscopy for detecting angle closure: a systematic review and meta-analysis |
title | Diagnostic accuracy of AS-OCT vs gonioscopy for detecting angle closure: a systematic review and meta-analysis |
title_full | Diagnostic accuracy of AS-OCT vs gonioscopy for detecting angle closure: a systematic review and meta-analysis |
title_fullStr | Diagnostic accuracy of AS-OCT vs gonioscopy for detecting angle closure: a systematic review and meta-analysis |
title_full_unstemmed | Diagnostic accuracy of AS-OCT vs gonioscopy for detecting angle closure: a systematic review and meta-analysis |
title_short | Diagnostic accuracy of AS-OCT vs gonioscopy for detecting angle closure: a systematic review and meta-analysis |
title_sort | diagnostic accuracy of as-oct vs gonioscopy for detecting angle closure: a systematic review and meta-analysis |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8255337/ https://www.ncbi.nlm.nih.gov/pubmed/34223989 http://dx.doi.org/10.1007/s00417-021-05271-4 |
work_keys_str_mv | AT desmondthomas diagnosticaccuracyofasoctvsgonioscopyfordetectingangleclosureasystematicreviewandmetaanalysis AT tranvincent diagnosticaccuracyofasoctvsgonioscopyfordetectingangleclosureasystematicreviewandmetaanalysis AT maharajmonish diagnosticaccuracyofasoctvsgonioscopyfordetectingangleclosureasystematicreviewandmetaanalysis AT carntnicole diagnosticaccuracyofasoctvsgonioscopyfordetectingangleclosureasystematicreviewandmetaanalysis AT whiteandrew diagnosticaccuracyofasoctvsgonioscopyfordetectingangleclosureasystematicreviewandmetaanalysis |