Cargando…

A Novel Mobile Acoustic Uroflowmetry: Comparison With Contemporary Uroflowmetry

PURPOSE: This study aimed to evaluate the accuracy and reliability of a new smartphone-based acoustic uroflowmetry compared to conventional uroflowmetry. METHODS: This was a prospective validation study enrolling 128 subjects from September 2017 to April 2018 comparing a novel acoustic uroflowmetry...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Young Ju, Kim, Michelle M., Song, Sang Hun, Lee, Sangchul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Continence Society 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8255819/
https://www.ncbi.nlm.nih.gov/pubmed/33387990
http://dx.doi.org/10.5213/inj.2040250.125
_version_ 1783717987921952768
author Lee, Young Ju
Kim, Michelle M.
Song, Sang Hun
Lee, Sangchul
author_facet Lee, Young Ju
Kim, Michelle M.
Song, Sang Hun
Lee, Sangchul
author_sort Lee, Young Ju
collection PubMed
description PURPOSE: This study aimed to evaluate the accuracy and reliability of a new smartphone-based acoustic uroflowmetry compared to conventional uroflowmetry. METHODS: This was a prospective validation study enrolling 128 subjects from September 2017 to April 2018 comparing a novel acoustic uroflowmetry to conventional uroflowmetry in an outpatient urologic clinic at Seoul National University Bundang Hospital. Visual comparison of flow patterns and uroflow parameters such as maximum flow rate (Qmax), average flow rate (Qavg), and voided volume were compared between the 2 techniques. Reliability and accuracy of the uroflowmetry results were compared using Pearson correlation coefficient (PCC) and Student t-test, respectively. RESULTS: One hundred twelve participants were included in the study. Of these, 77 had baseline urologic comorbidities while 35 were normal participants. Flow patterns between the 2 uroflowmetry techniques demonstrated strong visual correlation. When compared to conventional uroflowmetry, all 3 parameters of voiding in male participants showed a very robust correlation with PCC of 0.88, 0.91, and 0.95 for Qmax, Qavg, and voided volume, respectively. Among female participants, we observed a PCC of 0.78, 0.93, and 0.96 for Qmax, Qavg, and voided volume, respectively. The Qmax showed a statistically significant difference in both sexes between the 2 methods, although the absolute value was small. CONCLUSIONS: Uroflowmetry using acoustic analysis demonstrates comparable findings to conventional uroflowmetry. This provides an opportunity to perform uroflowmetry in the clinic or at home in a reliable, inexpensive manner. Future large-scale prospective studies are required to further validate our results.
format Online
Article
Text
id pubmed-8255819
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Continence Society
record_format MEDLINE/PubMed
spelling pubmed-82558192021-07-16 A Novel Mobile Acoustic Uroflowmetry: Comparison With Contemporary Uroflowmetry Lee, Young Ju Kim, Michelle M. Song, Sang Hun Lee, Sangchul Int Neurourol J Original Article PURPOSE: This study aimed to evaluate the accuracy and reliability of a new smartphone-based acoustic uroflowmetry compared to conventional uroflowmetry. METHODS: This was a prospective validation study enrolling 128 subjects from September 2017 to April 2018 comparing a novel acoustic uroflowmetry to conventional uroflowmetry in an outpatient urologic clinic at Seoul National University Bundang Hospital. Visual comparison of flow patterns and uroflow parameters such as maximum flow rate (Qmax), average flow rate (Qavg), and voided volume were compared between the 2 techniques. Reliability and accuracy of the uroflowmetry results were compared using Pearson correlation coefficient (PCC) and Student t-test, respectively. RESULTS: One hundred twelve participants were included in the study. Of these, 77 had baseline urologic comorbidities while 35 were normal participants. Flow patterns between the 2 uroflowmetry techniques demonstrated strong visual correlation. When compared to conventional uroflowmetry, all 3 parameters of voiding in male participants showed a very robust correlation with PCC of 0.88, 0.91, and 0.95 for Qmax, Qavg, and voided volume, respectively. Among female participants, we observed a PCC of 0.78, 0.93, and 0.96 for Qmax, Qavg, and voided volume, respectively. The Qmax showed a statistically significant difference in both sexes between the 2 methods, although the absolute value was small. CONCLUSIONS: Uroflowmetry using acoustic analysis demonstrates comparable findings to conventional uroflowmetry. This provides an opportunity to perform uroflowmetry in the clinic or at home in a reliable, inexpensive manner. Future large-scale prospective studies are required to further validate our results. Korean Continence Society 2021-06 2021-01-04 /pmc/articles/PMC8255819/ /pubmed/33387990 http://dx.doi.org/10.5213/inj.2040250.125 Text en Copyright © 2021 Korean Continence Society https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Young Ju
Kim, Michelle M.
Song, Sang Hun
Lee, Sangchul
A Novel Mobile Acoustic Uroflowmetry: Comparison With Contemporary Uroflowmetry
title A Novel Mobile Acoustic Uroflowmetry: Comparison With Contemporary Uroflowmetry
title_full A Novel Mobile Acoustic Uroflowmetry: Comparison With Contemporary Uroflowmetry
title_fullStr A Novel Mobile Acoustic Uroflowmetry: Comparison With Contemporary Uroflowmetry
title_full_unstemmed A Novel Mobile Acoustic Uroflowmetry: Comparison With Contemporary Uroflowmetry
title_short A Novel Mobile Acoustic Uroflowmetry: Comparison With Contemporary Uroflowmetry
title_sort novel mobile acoustic uroflowmetry: comparison with contemporary uroflowmetry
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8255819/
https://www.ncbi.nlm.nih.gov/pubmed/33387990
http://dx.doi.org/10.5213/inj.2040250.125
work_keys_str_mv AT leeyoungju anovelmobileacousticuroflowmetrycomparisonwithcontemporaryuroflowmetry
AT kimmichellem anovelmobileacousticuroflowmetrycomparisonwithcontemporaryuroflowmetry
AT songsanghun anovelmobileacousticuroflowmetrycomparisonwithcontemporaryuroflowmetry
AT leesangchul anovelmobileacousticuroflowmetrycomparisonwithcontemporaryuroflowmetry
AT leeyoungju novelmobileacousticuroflowmetrycomparisonwithcontemporaryuroflowmetry
AT kimmichellem novelmobileacousticuroflowmetrycomparisonwithcontemporaryuroflowmetry
AT songsanghun novelmobileacousticuroflowmetrycomparisonwithcontemporaryuroflowmetry
AT leesangchul novelmobileacousticuroflowmetrycomparisonwithcontemporaryuroflowmetry