Cargando…

Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging

Subject motion in positron emission tomography (PET) is a key factor that degrades image resolution and quality, limiting its potential capabilities. Correcting for it is complicated due to the lack of sufficient measured PET data from each position. This poses a significant barrier in calculating t...

Descripción completa

Detalles Bibliográficos
Autores principales: Polycarpou, Irene, Soultanidis, Georgios, Tsoumpas, Charalampos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8255946/
https://www.ncbi.nlm.nih.gov/pubmed/34218675
http://dx.doi.org/10.1098/rsta.2020.0207
_version_ 1783718017645936640
author Polycarpou, Irene
Soultanidis, Georgios
Tsoumpas, Charalampos
author_facet Polycarpou, Irene
Soultanidis, Georgios
Tsoumpas, Charalampos
author_sort Polycarpou, Irene
collection PubMed
description Subject motion in positron emission tomography (PET) is a key factor that degrades image resolution and quality, limiting its potential capabilities. Correcting for it is complicated due to the lack of sufficient measured PET data from each position. This poses a significant barrier in calculating the amount of motion occurring during a scan. Motion correction can be implemented at different stages of data processing either during or after image reconstruction, and once applied accurately can substantially improve image quality and information accuracy. With the development of integrated PET-MRI (magnetic resonance imaging) scanners, internal organ motion can be measured concurrently with both PET and MRI. In this review paper, we explore the synergistic use of PET and MRI data to correct for any motion that affects the PET images. Different types of motion that can occur during PET-MRI acquisitions are presented and the associated motion detection, estimation and correction methods are reviewed. Finally, some highlights from recent literature in selected human and animal imaging applications are presented and the importance of motion correction for accurate kinetic modelling in dynamic PET-MRI is emphasized. This article is part of the theme issue ‘Synergistic tomographic image reconstruction: part 2’.
format Online
Article
Text
id pubmed-8255946
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Royal Society Publishing
record_format MEDLINE/PubMed
spelling pubmed-82559462022-02-02 Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging Polycarpou, Irene Soultanidis, Georgios Tsoumpas, Charalampos Philos Trans A Math Phys Eng Sci Articles Subject motion in positron emission tomography (PET) is a key factor that degrades image resolution and quality, limiting its potential capabilities. Correcting for it is complicated due to the lack of sufficient measured PET data from each position. This poses a significant barrier in calculating the amount of motion occurring during a scan. Motion correction can be implemented at different stages of data processing either during or after image reconstruction, and once applied accurately can substantially improve image quality and information accuracy. With the development of integrated PET-MRI (magnetic resonance imaging) scanners, internal organ motion can be measured concurrently with both PET and MRI. In this review paper, we explore the synergistic use of PET and MRI data to correct for any motion that affects the PET images. Different types of motion that can occur during PET-MRI acquisitions are presented and the associated motion detection, estimation and correction methods are reviewed. Finally, some highlights from recent literature in selected human and animal imaging applications are presented and the importance of motion correction for accurate kinetic modelling in dynamic PET-MRI is emphasized. This article is part of the theme issue ‘Synergistic tomographic image reconstruction: part 2’. The Royal Society Publishing 2021-08-23 2021-07-05 /pmc/articles/PMC8255946/ /pubmed/34218675 http://dx.doi.org/10.1098/rsta.2020.0207 Text en © 2021 The Authors. https://creativecommons.org/licenses/by/4.0/Published by the Royal Society under the terms of the Creative Commons Attribution License http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, provided the original author and source are credited.
spellingShingle Articles
Polycarpou, Irene
Soultanidis, Georgios
Tsoumpas, Charalampos
Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging
title Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging
title_full Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging
title_fullStr Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging
title_full_unstemmed Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging
title_short Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging
title_sort synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8255946/
https://www.ncbi.nlm.nih.gov/pubmed/34218675
http://dx.doi.org/10.1098/rsta.2020.0207
work_keys_str_mv AT polycarpouirene synergisticmotioncompensationstrategiesforpositronemissiontomographywhenacquiredsimultaneouslywithmagneticresonanceimaging
AT soultanidisgeorgios synergisticmotioncompensationstrategiesforpositronemissiontomographywhenacquiredsimultaneouslywithmagneticresonanceimaging
AT tsoumpascharalampos synergisticmotioncompensationstrategiesforpositronemissiontomographywhenacquiredsimultaneouslywithmagneticresonanceimaging