Cargando…

Comparison of saliva with healthcare workers- and patient-collected swabs in the diagnosis of COVID-19 in a large cohort

BACKGROUND: A considerable amount of evidence demonstrates the potential of saliva in the diagnosis of COVID-19. Our aim was to determine the sensitivity of saliva versus swabs collected by healthcare workers (HCWs) and patients themselves to assess whether saliva detection can be offered as a cost-...

Descripción completa

Detalles Bibliográficos
Autores principales: Sasikala, Mitnala, Sadhana, Yelamanchili, Vijayasarathy, Ketavarapu, Gupta, Anand, Daram, Sarala Kumari, Podduturi, Naveen Chander Reddy, Reddy, Duvvur Nageshwar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8256642/
https://www.ncbi.nlm.nih.gov/pubmed/34225656
http://dx.doi.org/10.1186/s12879-021-06343-w
_version_ 1783718138688307200
author Sasikala, Mitnala
Sadhana, Yelamanchili
Vijayasarathy, Ketavarapu
Gupta, Anand
Daram, Sarala Kumari
Podduturi, Naveen Chander Reddy
Reddy, Duvvur Nageshwar
author_facet Sasikala, Mitnala
Sadhana, Yelamanchili
Vijayasarathy, Ketavarapu
Gupta, Anand
Daram, Sarala Kumari
Podduturi, Naveen Chander Reddy
Reddy, Duvvur Nageshwar
author_sort Sasikala, Mitnala
collection PubMed
description BACKGROUND: A considerable amount of evidence demonstrates the potential of saliva in the diagnosis of COVID-19. Our aim was to determine the sensitivity of saliva versus swabs collected by healthcare workers (HCWs) and patients themselves to assess whether saliva detection can be offered as a cost-effective, risk-free method of SARS-CoV-2 detection. METHODS: This study was conducted in a hospital involving outpatients and hospitalized patients. A total of 3018 outpatients were tested. Of these, 200 qRT-PCR-confirmed SARS-CoV-2-positive patients were recruited for further study. In addition, 101 SARS-CoV-2-positive hospitalized patients with symptoms were also enrolled in the study. From outpatients, HCWs collected nasopharyngeal swabs (NPS), saliva were obtained. From inpatients, HCWs collected swabs, patient-collected swabs, and saliva were obtained. qRT-PCR was performed to detect SARS-CoV-2 by TAQPATH assay to determine the sensitivity of saliva detection. Sensitivity, specificity and positive/negative predictive values (PPV, NPV) of detecting SARS-CoV-2 were calculated using MedCalc. RESULTS: Of 3018 outpatients (asymptomatic: 2683, symptomatic: 335) tested by qRT-PCR, 200 were positive (males: 140, females: 60; aged 37.9 ± 12.8 years; (81 asymptomatic, 119 symptomatic). Of these, saliva was positive in 128 (64%); 39 of 81 asymptomatic (47%),89 of 119 symptomatic patients (74.8%). Sensitivity of detection was 60.9% (55.4–66.3%, CI 95%), with a negative predictive value of 36%(32.9–39.2%, CI 95%).Among 101 hospitalized patients (males:65, females: 36; aged 53.48 ± 15.6 years), with HCW collected NPS as comparator, sensitivity of saliva was 56.1% (47.5–64.5, CI 95%), specificity 63.5%(50.4–75.3, CI95%) with PPV of 77.2% and NPV of 39.6% and that of self-swab was 52.3%(44–60.5%, CI95%), specificity 56.6% (42.3–70.2%, CI95%) with PPV 77.2% and NPV29.7%. Comparison of positivity with the onset of symptoms revealed highest detection in saliva on day 3 after onset of symptoms. Additionally, only saliva was positive in 13 (12.8%) hospitalized patients. CONCLUSION: Saliva which is easier to collect than nasopharyngeal swab is a viable alternate to detect SARS-COV-2 in symptomatic patients in the early stage of onset of symptoms. Although saliva is currently not recommended for screening asymptomatic patients, optimization of collection and uniform timing of sampling might improve the sensitivity enabling its use as a screening tool at community level.
format Online
Article
Text
id pubmed-8256642
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-82566422021-07-06 Comparison of saliva with healthcare workers- and patient-collected swabs in the diagnosis of COVID-19 in a large cohort Sasikala, Mitnala Sadhana, Yelamanchili Vijayasarathy, Ketavarapu Gupta, Anand Daram, Sarala Kumari Podduturi, Naveen Chander Reddy Reddy, Duvvur Nageshwar BMC Infect Dis Research Article BACKGROUND: A considerable amount of evidence demonstrates the potential of saliva in the diagnosis of COVID-19. Our aim was to determine the sensitivity of saliva versus swabs collected by healthcare workers (HCWs) and patients themselves to assess whether saliva detection can be offered as a cost-effective, risk-free method of SARS-CoV-2 detection. METHODS: This study was conducted in a hospital involving outpatients and hospitalized patients. A total of 3018 outpatients were tested. Of these, 200 qRT-PCR-confirmed SARS-CoV-2-positive patients were recruited for further study. In addition, 101 SARS-CoV-2-positive hospitalized patients with symptoms were also enrolled in the study. From outpatients, HCWs collected nasopharyngeal swabs (NPS), saliva were obtained. From inpatients, HCWs collected swabs, patient-collected swabs, and saliva were obtained. qRT-PCR was performed to detect SARS-CoV-2 by TAQPATH assay to determine the sensitivity of saliva detection. Sensitivity, specificity and positive/negative predictive values (PPV, NPV) of detecting SARS-CoV-2 were calculated using MedCalc. RESULTS: Of 3018 outpatients (asymptomatic: 2683, symptomatic: 335) tested by qRT-PCR, 200 were positive (males: 140, females: 60; aged 37.9 ± 12.8 years; (81 asymptomatic, 119 symptomatic). Of these, saliva was positive in 128 (64%); 39 of 81 asymptomatic (47%),89 of 119 symptomatic patients (74.8%). Sensitivity of detection was 60.9% (55.4–66.3%, CI 95%), with a negative predictive value of 36%(32.9–39.2%, CI 95%).Among 101 hospitalized patients (males:65, females: 36; aged 53.48 ± 15.6 years), with HCW collected NPS as comparator, sensitivity of saliva was 56.1% (47.5–64.5, CI 95%), specificity 63.5%(50.4–75.3, CI95%) with PPV of 77.2% and NPV of 39.6% and that of self-swab was 52.3%(44–60.5%, CI95%), specificity 56.6% (42.3–70.2%, CI95%) with PPV 77.2% and NPV29.7%. Comparison of positivity with the onset of symptoms revealed highest detection in saliva on day 3 after onset of symptoms. Additionally, only saliva was positive in 13 (12.8%) hospitalized patients. CONCLUSION: Saliva which is easier to collect than nasopharyngeal swab is a viable alternate to detect SARS-COV-2 in symptomatic patients in the early stage of onset of symptoms. Although saliva is currently not recommended for screening asymptomatic patients, optimization of collection and uniform timing of sampling might improve the sensitivity enabling its use as a screening tool at community level. BioMed Central 2021-07-05 /pmc/articles/PMC8256642/ /pubmed/34225656 http://dx.doi.org/10.1186/s12879-021-06343-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Sasikala, Mitnala
Sadhana, Yelamanchili
Vijayasarathy, Ketavarapu
Gupta, Anand
Daram, Sarala Kumari
Podduturi, Naveen Chander Reddy
Reddy, Duvvur Nageshwar
Comparison of saliva with healthcare workers- and patient-collected swabs in the diagnosis of COVID-19 in a large cohort
title Comparison of saliva with healthcare workers- and patient-collected swabs in the diagnosis of COVID-19 in a large cohort
title_full Comparison of saliva with healthcare workers- and patient-collected swabs in the diagnosis of COVID-19 in a large cohort
title_fullStr Comparison of saliva with healthcare workers- and patient-collected swabs in the diagnosis of COVID-19 in a large cohort
title_full_unstemmed Comparison of saliva with healthcare workers- and patient-collected swabs in the diagnosis of COVID-19 in a large cohort
title_short Comparison of saliva with healthcare workers- and patient-collected swabs in the diagnosis of COVID-19 in a large cohort
title_sort comparison of saliva with healthcare workers- and patient-collected swabs in the diagnosis of covid-19 in a large cohort
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8256642/
https://www.ncbi.nlm.nih.gov/pubmed/34225656
http://dx.doi.org/10.1186/s12879-021-06343-w
work_keys_str_mv AT sasikalamitnala comparisonofsalivawithhealthcareworkersandpatientcollectedswabsinthediagnosisofcovid19inalargecohort
AT sadhanayelamanchili comparisonofsalivawithhealthcareworkersandpatientcollectedswabsinthediagnosisofcovid19inalargecohort
AT vijayasarathyketavarapu comparisonofsalivawithhealthcareworkersandpatientcollectedswabsinthediagnosisofcovid19inalargecohort
AT guptaanand comparisonofsalivawithhealthcareworkersandpatientcollectedswabsinthediagnosisofcovid19inalargecohort
AT daramsaralakumari comparisonofsalivawithhealthcareworkersandpatientcollectedswabsinthediagnosisofcovid19inalargecohort
AT podduturinaveenchanderreddy comparisonofsalivawithhealthcareworkersandpatientcollectedswabsinthediagnosisofcovid19inalargecohort
AT reddyduvvurnageshwar comparisonofsalivawithhealthcareworkersandpatientcollectedswabsinthediagnosisofcovid19inalargecohort