Cargando…

Analytical validation of GMEX rapid point-of-care CYP2C19 genotyping system for the CHANCE-2 trial

BACKGROUND AND PURPOSE: Rapid genotyping is useful for guiding early antiplatelet therapy in patients with high-risk nondisabling ischaemic cerebrovascular events (HR-NICE). Conventional genetic testing methods used in CYP2C19 genotype-guided antiplatelet therapy for patients with HR-NICE did not sa...

Descripción completa

Detalles Bibliográficos
Autores principales: Meng, Xia, Wang, Anxin, Zhang, Guojun, Niu, Siying, Li, Wei, Han, Sifei, Fang, Fang, Zhao, Xingquan, Dong, Kehui, Jin, Zening, Zheng, Huaguang, Chen, Kelin, Li, Hao, Yang, Chengyuan, Wang, Yongjun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8258065/
https://www.ncbi.nlm.nih.gov/pubmed/33952669
http://dx.doi.org/10.1136/svn-2021-000874
Descripción
Sumario:BACKGROUND AND PURPOSE: Rapid genotyping is useful for guiding early antiplatelet therapy in patients with high-risk nondisabling ischaemic cerebrovascular events (HR-NICE). Conventional genetic testing methods used in CYP2C19 genotype-guided antiplatelet therapy for patients with HR-NICE did not satisfy the needs of the Clopidogrel in High-Risk Patients with Acute Nondisabling Cerebrovascular Events (CHANCE)-2 trial. Therefore, we developed the rapid-genotyping GMEX (point-of-care) system to meet the needs of the CHANCE-2 trial. METHODS: Healthy individuals and patients with history of cardiovascular diseases (n=408) were enrolled from six centres of the CHANCE-2 trial. We compared the laboratory-based genomic test results with Sanger sequencing test results for accuracy verification. Next, we demonstrated the accuracy, timeliness and clinical operability of the GMEX system compared with laboratory-based technology (YZY Kit) to verify whether the GMEX system satisfies the needs of the CHANCE-2 trial. RESULTS: Genotypes reported by the GMEX system showed 100% agreement with those determined by using the YZY Kit and Sanger sequencing for all three CYP2C19 alleles (*2, *3 and *17) tested. The average result’s turnaround times for the GMEX and YZY Kit methods were 85.0 (IQR: 85.0–86.0) and 1630.0 (IQR: 354.0–7594.0) min (p<0.001), respectively. CONCLUSIONS: Our data suggest that the GMEX system is a reliable and feasible point-of-care system for rapid CYP2C19 genotyping for the CHANCE-2 trial or related clinical and research applications.