Cargando…
A multicenter, hospital-based and non-inferiority study for diagnostic efficacy of automated whole breast ultrasound for breast cancer in China
This study is the first multi-center non-inferiority study that aims to critically evaluate the effectiveness of HHUS/ABUS in China breast cancer detection. This was a multicenter hospital-based study. Five hospitals participated in this study. Women (30–69 years old) with defined criteria were invi...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8260602/ https://www.ncbi.nlm.nih.gov/pubmed/34230562 http://dx.doi.org/10.1038/s41598-021-93350-1 |
_version_ | 1783718842541801472 |
---|---|
author | Xin, Yujing Zhang, Xinyuan Yang, Yi Chen, Yi Wang, Yanan Zhou, Xiang Qiao, Youlin |
author_facet | Xin, Yujing Zhang, Xinyuan Yang, Yi Chen, Yi Wang, Yanan Zhou, Xiang Qiao, Youlin |
author_sort | Xin, Yujing |
collection | PubMed |
description | This study is the first multi-center non-inferiority study that aims to critically evaluate the effectiveness of HHUS/ABUS in China breast cancer detection. This was a multicenter hospital-based study. Five hospitals participated in this study. Women (30–69 years old) with defined criteria were invited for breast examination by HHUS, ABUS or/and mammography. For BI-RADS category 3, an additional magnetic resonance imaging (MRI) test was provided to distinguish the true negative results from false negative results. For women classified as BI-RADS category 4 or 5, either core aspiration biopsy or surgical biopsy was done to confirm the diagnosis. Between February 2016 and March 2017, 2844 women signed the informed consent form, and 1947 of them involved in final analysis (680 were 30 to 39 years old, 1267 were 40 to 69 years old).For all participants, ABUS sensitivity (91.81%) compared with HHUS sensitivity (94.70%) with non-inferior Z tests, P = 0.015. In the 40–69 age group, non-inferior Z tests showed that ABUS sensitivity (93.01%) was non-inferior to MG sensitivity (86.02%) with P < 0.001 and HHUS sensitivity (95.44%) was non-inferior to MG sensitivity (86.02%) with P < 0.001. Sensitivity of ABUS and HHUS are all superior to that of MG with P < 0.001 by superior test.For all participants, ABUS specificity (92.89%) was non-inferior to HHUS specificity (89.36%) with P < 0.001. Superiority test show that specificity of ABUS was superior to that of HHUS with P < 0.001. In the 40–69 age group, ABUS specificity (92.86%) was non-inferior to MG specificity (91.68%) with P < 0.001 and HHUS specificity (89.55%) was non-inferior to MG specificity (91.68%) with P < 0.001. ABUS is not superior to MG with P = 0.114 by superior test. The sensitivity of ABUS/HHUS is superior to that of MG. The specificity of ABUS/HHUS is non-inferior to that of MG. In China, for an experienced US radiologist, both HHUS and ABUS have better diagnostic efficacy than MG in symptomatic individuals. |
format | Online Article Text |
id | pubmed-8260602 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-82606022021-07-08 A multicenter, hospital-based and non-inferiority study for diagnostic efficacy of automated whole breast ultrasound for breast cancer in China Xin, Yujing Zhang, Xinyuan Yang, Yi Chen, Yi Wang, Yanan Zhou, Xiang Qiao, Youlin Sci Rep Article This study is the first multi-center non-inferiority study that aims to critically evaluate the effectiveness of HHUS/ABUS in China breast cancer detection. This was a multicenter hospital-based study. Five hospitals participated in this study. Women (30–69 years old) with defined criteria were invited for breast examination by HHUS, ABUS or/and mammography. For BI-RADS category 3, an additional magnetic resonance imaging (MRI) test was provided to distinguish the true negative results from false negative results. For women classified as BI-RADS category 4 or 5, either core aspiration biopsy or surgical biopsy was done to confirm the diagnosis. Between February 2016 and March 2017, 2844 women signed the informed consent form, and 1947 of them involved in final analysis (680 were 30 to 39 years old, 1267 were 40 to 69 years old).For all participants, ABUS sensitivity (91.81%) compared with HHUS sensitivity (94.70%) with non-inferior Z tests, P = 0.015. In the 40–69 age group, non-inferior Z tests showed that ABUS sensitivity (93.01%) was non-inferior to MG sensitivity (86.02%) with P < 0.001 and HHUS sensitivity (95.44%) was non-inferior to MG sensitivity (86.02%) with P < 0.001. Sensitivity of ABUS and HHUS are all superior to that of MG with P < 0.001 by superior test.For all participants, ABUS specificity (92.89%) was non-inferior to HHUS specificity (89.36%) with P < 0.001. Superiority test show that specificity of ABUS was superior to that of HHUS with P < 0.001. In the 40–69 age group, ABUS specificity (92.86%) was non-inferior to MG specificity (91.68%) with P < 0.001 and HHUS specificity (89.55%) was non-inferior to MG specificity (91.68%) with P < 0.001. ABUS is not superior to MG with P = 0.114 by superior test. The sensitivity of ABUS/HHUS is superior to that of MG. The specificity of ABUS/HHUS is non-inferior to that of MG. In China, for an experienced US radiologist, both HHUS and ABUS have better diagnostic efficacy than MG in symptomatic individuals. Nature Publishing Group UK 2021-07-06 /pmc/articles/PMC8260602/ /pubmed/34230562 http://dx.doi.org/10.1038/s41598-021-93350-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Xin, Yujing Zhang, Xinyuan Yang, Yi Chen, Yi Wang, Yanan Zhou, Xiang Qiao, Youlin A multicenter, hospital-based and non-inferiority study for diagnostic efficacy of automated whole breast ultrasound for breast cancer in China |
title | A multicenter, hospital-based and non-inferiority study for diagnostic efficacy of automated whole breast ultrasound for breast cancer in China |
title_full | A multicenter, hospital-based and non-inferiority study for diagnostic efficacy of automated whole breast ultrasound for breast cancer in China |
title_fullStr | A multicenter, hospital-based and non-inferiority study for diagnostic efficacy of automated whole breast ultrasound for breast cancer in China |
title_full_unstemmed | A multicenter, hospital-based and non-inferiority study for diagnostic efficacy of automated whole breast ultrasound for breast cancer in China |
title_short | A multicenter, hospital-based and non-inferiority study for diagnostic efficacy of automated whole breast ultrasound for breast cancer in China |
title_sort | multicenter, hospital-based and non-inferiority study for diagnostic efficacy of automated whole breast ultrasound for breast cancer in china |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8260602/ https://www.ncbi.nlm.nih.gov/pubmed/34230562 http://dx.doi.org/10.1038/s41598-021-93350-1 |
work_keys_str_mv | AT xinyujing amulticenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina AT zhangxinyuan amulticenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina AT yangyi amulticenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina AT chenyi amulticenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina AT wangyanan amulticenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina AT zhouxiang amulticenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina AT qiaoyoulin amulticenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina AT xinyujing multicenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina AT zhangxinyuan multicenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina AT yangyi multicenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina AT chenyi multicenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina AT wangyanan multicenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina AT zhouxiang multicenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina AT qiaoyoulin multicenterhospitalbasedandnoninferioritystudyfordiagnosticefficacyofautomatedwholebreastultrasoundforbreastcancerinchina |