Cargando…
A prototype device of microliter volume voltammetric pH sensor based on carbazole–quinone redox-probe tethered MWCNT modified three-in-one screen-printed electrode
As an alternate for the conventional glass-based pH sensor which is associated with problems like fragile nature, alkaline error, and potential drift, the development of a new redox-sensitive pH probe-modified electrode that could show potential, current-drift and surface-fouling free voltammetric p...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8260652/ https://www.ncbi.nlm.nih.gov/pubmed/34230547 http://dx.doi.org/10.1038/s41598-021-93368-5 |
_version_ | 1783718851006955520 |
---|---|
author | Srinivas, Sakthivel Ashokkumar, Krishnan Sriraghavan, Kamaraj Senthil Kumar, Annamalai |
author_facet | Srinivas, Sakthivel Ashokkumar, Krishnan Sriraghavan, Kamaraj Senthil Kumar, Annamalai |
author_sort | Srinivas, Sakthivel |
collection | PubMed |
description | As an alternate for the conventional glass-based pH sensor which is associated with problems like fragile nature, alkaline error, and potential drift, the development of a new redox-sensitive pH probe-modified electrode that could show potential, current-drift and surface-fouling free voltammetric pH sensing is a demanding research interest, recently. Herein, we report a substituted carbazole-quinone (Car-HQ) based new redox-active pH-sensitive probe that contains benzyl and bromo-substituents, immobilized multiwalled carbon nanotube modified glassy carbon (GCE/MWCNT@Car-HQ) and screen-printed three-in-one (SPE/MWCNT@Car-HQ) electrodes for selective, surface-fouling free pH sensor application. This new system showed a well-defined surface-confined redox peak at an apparent standard electrode potential, E(o)′ = − 0.160 V versus Ag/AgCl with surface-excess value, Γ = 47 n mol cm(−2) in pH 7 phosphate buffer solution. When tested with various electroactive chemicals and biochemicals such as cysteine, hydrazine, NADH, uric acid, and ascorbic acid, MWCNT@Car-HQ showed an unaltered redox-peak potential and current values without mediated oxidation/reduction behavior unlike the conventional hydroquinone, anthraquinone and other redox mediators based voltammetry sensors with serious electrocatalytic effects and in turn potential and current drifts. A strong π–π interaction, nitrogen-atom assisted surface orientation and C–C bond formation on the graphitic structure of MWCNT are the plausible reasons for stable and selective voltammetric pH sensing application of MWCNT@Car-HQ system. Using a programed/in-built three-in-one screen printed compatible potentiostat system, voltammetric pH sensing of 3 μL sample of urine, saliva, and orange juice samples with pH values comparable to that of milliliter volume-based pH-glass electrode measurements has been demonstrated. |
format | Online Article Text |
id | pubmed-8260652 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-82606522021-07-08 A prototype device of microliter volume voltammetric pH sensor based on carbazole–quinone redox-probe tethered MWCNT modified three-in-one screen-printed electrode Srinivas, Sakthivel Ashokkumar, Krishnan Sriraghavan, Kamaraj Senthil Kumar, Annamalai Sci Rep Article As an alternate for the conventional glass-based pH sensor which is associated with problems like fragile nature, alkaline error, and potential drift, the development of a new redox-sensitive pH probe-modified electrode that could show potential, current-drift and surface-fouling free voltammetric pH sensing is a demanding research interest, recently. Herein, we report a substituted carbazole-quinone (Car-HQ) based new redox-active pH-sensitive probe that contains benzyl and bromo-substituents, immobilized multiwalled carbon nanotube modified glassy carbon (GCE/MWCNT@Car-HQ) and screen-printed three-in-one (SPE/MWCNT@Car-HQ) electrodes for selective, surface-fouling free pH sensor application. This new system showed a well-defined surface-confined redox peak at an apparent standard electrode potential, E(o)′ = − 0.160 V versus Ag/AgCl with surface-excess value, Γ = 47 n mol cm(−2) in pH 7 phosphate buffer solution. When tested with various electroactive chemicals and biochemicals such as cysteine, hydrazine, NADH, uric acid, and ascorbic acid, MWCNT@Car-HQ showed an unaltered redox-peak potential and current values without mediated oxidation/reduction behavior unlike the conventional hydroquinone, anthraquinone and other redox mediators based voltammetry sensors with serious electrocatalytic effects and in turn potential and current drifts. A strong π–π interaction, nitrogen-atom assisted surface orientation and C–C bond formation on the graphitic structure of MWCNT are the plausible reasons for stable and selective voltammetric pH sensing application of MWCNT@Car-HQ system. Using a programed/in-built three-in-one screen printed compatible potentiostat system, voltammetric pH sensing of 3 μL sample of urine, saliva, and orange juice samples with pH values comparable to that of milliliter volume-based pH-glass electrode measurements has been demonstrated. Nature Publishing Group UK 2021-07-06 /pmc/articles/PMC8260652/ /pubmed/34230547 http://dx.doi.org/10.1038/s41598-021-93368-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Srinivas, Sakthivel Ashokkumar, Krishnan Sriraghavan, Kamaraj Senthil Kumar, Annamalai A prototype device of microliter volume voltammetric pH sensor based on carbazole–quinone redox-probe tethered MWCNT modified three-in-one screen-printed electrode |
title | A prototype device of microliter volume voltammetric pH sensor based on carbazole–quinone redox-probe tethered MWCNT modified three-in-one screen-printed electrode |
title_full | A prototype device of microliter volume voltammetric pH sensor based on carbazole–quinone redox-probe tethered MWCNT modified three-in-one screen-printed electrode |
title_fullStr | A prototype device of microliter volume voltammetric pH sensor based on carbazole–quinone redox-probe tethered MWCNT modified three-in-one screen-printed electrode |
title_full_unstemmed | A prototype device of microliter volume voltammetric pH sensor based on carbazole–quinone redox-probe tethered MWCNT modified three-in-one screen-printed electrode |
title_short | A prototype device of microliter volume voltammetric pH sensor based on carbazole–quinone redox-probe tethered MWCNT modified three-in-one screen-printed electrode |
title_sort | prototype device of microliter volume voltammetric ph sensor based on carbazole–quinone redox-probe tethered mwcnt modified three-in-one screen-printed electrode |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8260652/ https://www.ncbi.nlm.nih.gov/pubmed/34230547 http://dx.doi.org/10.1038/s41598-021-93368-5 |
work_keys_str_mv | AT srinivassakthivel aprototypedeviceofmicrolitervolumevoltammetricphsensorbasedoncarbazolequinoneredoxprobetetheredmwcntmodifiedthreeinonescreenprintedelectrode AT ashokkumarkrishnan aprototypedeviceofmicrolitervolumevoltammetricphsensorbasedoncarbazolequinoneredoxprobetetheredmwcntmodifiedthreeinonescreenprintedelectrode AT sriraghavankamaraj aprototypedeviceofmicrolitervolumevoltammetricphsensorbasedoncarbazolequinoneredoxprobetetheredmwcntmodifiedthreeinonescreenprintedelectrode AT senthilkumarannamalai aprototypedeviceofmicrolitervolumevoltammetricphsensorbasedoncarbazolequinoneredoxprobetetheredmwcntmodifiedthreeinonescreenprintedelectrode AT srinivassakthivel prototypedeviceofmicrolitervolumevoltammetricphsensorbasedoncarbazolequinoneredoxprobetetheredmwcntmodifiedthreeinonescreenprintedelectrode AT ashokkumarkrishnan prototypedeviceofmicrolitervolumevoltammetricphsensorbasedoncarbazolequinoneredoxprobetetheredmwcntmodifiedthreeinonescreenprintedelectrode AT sriraghavankamaraj prototypedeviceofmicrolitervolumevoltammetricphsensorbasedoncarbazolequinoneredoxprobetetheredmwcntmodifiedthreeinonescreenprintedelectrode AT senthilkumarannamalai prototypedeviceofmicrolitervolumevoltammetricphsensorbasedoncarbazolequinoneredoxprobetetheredmwcntmodifiedthreeinonescreenprintedelectrode |