Cargando…

Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips

Cadaver tissue has been identified as the highest-fidelity anatomical representation in terms of the training for orthopedic surgery, including for arthroscopy of a damaged hip labrum. However, hip labrum stiffness in vivo and in cadavers has not been directly compared. The purpose of this study was...

Descripción completa

Detalles Bibliográficos
Autores principales: Hananouchi, Takehito, Uchida, Soshi, Hashimoto, Yusuke, Noboru, Funakoshi, Aoki, Stephen K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8261628/
https://www.ncbi.nlm.nih.gov/pubmed/34072623
http://dx.doi.org/10.3390/biomimetics6020035
_version_ 1783719046733103104
author Hananouchi, Takehito
Uchida, Soshi
Hashimoto, Yusuke
Noboru, Funakoshi
Aoki, Stephen K.
author_facet Hananouchi, Takehito
Uchida, Soshi
Hashimoto, Yusuke
Noboru, Funakoshi
Aoki, Stephen K.
author_sort Hananouchi, Takehito
collection PubMed
description Cadaver tissue has been identified as the highest-fidelity anatomical representation in terms of the training for orthopedic surgery, including for arthroscopy of a damaged hip labrum. However, hip labrum stiffness in vivo and in cadavers has not been directly compared. The purpose of this study was to compare in vivo and cadaveric hip labrum stiffness during pull-probing with a force sensor. We measured the resistance force of the hip labrum in ten patients during hip arthroscopy (i.e., in vivo) and compared it with ten cadavers, both intact and detached from the acetabulum, using a surgical knife. We confirmed a partial labral tear (i.e., not detached fully from the rim) at an antero-superior potion in all of the patients. The mean highest resistance levels for the hip labrum in the patients (4.7 N) were significantly lower than the intact cadaveric labrum (8.3 N), and slightly higher than the detached labrum (4.2 N). In this study, the stiffness of the cadaveric labrum tissue was similar to that of the in-vivo hip labrum.
format Online
Article
Text
id pubmed-8261628
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82616282021-07-08 Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips Hananouchi, Takehito Uchida, Soshi Hashimoto, Yusuke Noboru, Funakoshi Aoki, Stephen K. Biomimetics (Basel) Article Cadaver tissue has been identified as the highest-fidelity anatomical representation in terms of the training for orthopedic surgery, including for arthroscopy of a damaged hip labrum. However, hip labrum stiffness in vivo and in cadavers has not been directly compared. The purpose of this study was to compare in vivo and cadaveric hip labrum stiffness during pull-probing with a force sensor. We measured the resistance force of the hip labrum in ten patients during hip arthroscopy (i.e., in vivo) and compared it with ten cadavers, both intact and detached from the acetabulum, using a surgical knife. We confirmed a partial labral tear (i.e., not detached fully from the rim) at an antero-superior potion in all of the patients. The mean highest resistance levels for the hip labrum in the patients (4.7 N) were significantly lower than the intact cadaveric labrum (8.3 N), and slightly higher than the detached labrum (4.2 N). In this study, the stiffness of the cadaveric labrum tissue was similar to that of the in-vivo hip labrum. MDPI 2021-05-31 /pmc/articles/PMC8261628/ /pubmed/34072623 http://dx.doi.org/10.3390/biomimetics6020035 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hananouchi, Takehito
Uchida, Soshi
Hashimoto, Yusuke
Noboru, Funakoshi
Aoki, Stephen K.
Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips
title Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips
title_full Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips
title_fullStr Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips
title_full_unstemmed Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips
title_short Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips
title_sort comparison of labrum resistance force while pull-probing in vivo and cadaveric hips
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8261628/
https://www.ncbi.nlm.nih.gov/pubmed/34072623
http://dx.doi.org/10.3390/biomimetics6020035
work_keys_str_mv AT hananouchitakehito comparisonoflabrumresistanceforcewhilepullprobinginvivoandcadaverichips
AT uchidasoshi comparisonoflabrumresistanceforcewhilepullprobinginvivoandcadaverichips
AT hashimotoyusuke comparisonoflabrumresistanceforcewhilepullprobinginvivoandcadaverichips
AT noborufunakoshi comparisonoflabrumresistanceforcewhilepullprobinginvivoandcadaverichips
AT aokistephenk comparisonoflabrumresistanceforcewhilepullprobinginvivoandcadaverichips