Compliance with the ISO 27020:2019 norm of a sample of currently available preadjusted Orthodontic bracket systems. Are the actual dimensions as expected?

BACKGROUND: Determine the exact slot dimension of a sample of a MBT prescription stainless steel conventional brackets from different manufacturers to compare the actual values with the nominal ones declared by the manufacturers and to verify the compliance with tolerance limits given by the ISO 270...

Descripción completa

Detalles Bibliográficos
Autores principales: Bernés Martínez, Laura, Garcovich, Daniele, España Pamplona, Pilar, Adobes Martín, Milagros Adobes, Alvarado Lorenzo, Alfonso
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8261997/
https://www.ncbi.nlm.nih.gov/pubmed/34233698
http://dx.doi.org/10.1186/s13005-021-00276-0
_version_ 1783719109511348224
author Bernés Martínez, Laura
Garcovich, Daniele
España Pamplona, Pilar
Adobes Martín, Milagros Adobes
Alvarado Lorenzo, Alfonso
author_facet Bernés Martínez, Laura
Garcovich, Daniele
España Pamplona, Pilar
Adobes Martín, Milagros Adobes
Alvarado Lorenzo, Alfonso
author_sort Bernés Martínez, Laura
collection PubMed
description BACKGROUND: Determine the exact slot dimension of a sample of a MBT prescription stainless steel conventional brackets from different manufacturers to compare the actual values with the nominal ones declared by the manufacturers and to verify the compliance with tolerance limits given by the ISO 27020:2019. Different batches from each manufacturer were evaluated to determine whether or not they are different in size. In addition, the geometry of the slot walls was assessed. METHODS: 360 stainless steel preadjusted orthodontic brackets of 12 different manufacturers were assessed. All brackets had a nominal slot size of 0.022 by 0.028 inches, belonged to the right upper central incisor, and were fabricated with the metal injection molding technique (MIM). For each manufacturer, three different manufacturing batches were evaluated. Brackets were coded using a single-blind design. RESULTS: All bracket systems in the study group except one displayed a statistically significant difference with the nominal declared value, although only four of the systems did not comply with the tolerance limits established by the ISO 27020:2019. In most of the systems, the slot height was oversized when compared to the nominal one. A significant interbatch variability was found in most of the evaluated systems. Most of the brackets walls were divergent. CONCLUSIONS: The dimensional accuracy of commercially available metal brackets is not guaranteed. The respect for the norm should be enforced as well as the quality controls along the manufacturing process since orthodontic brackets are a precision medical device.
format Online
Article
Text
id pubmed-8261997
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-82619972021-07-07 Compliance with the ISO 27020:2019 norm of a sample of currently available preadjusted Orthodontic bracket systems. Are the actual dimensions as expected? Bernés Martínez, Laura Garcovich, Daniele España Pamplona, Pilar Adobes Martín, Milagros Adobes Alvarado Lorenzo, Alfonso Head Face Med Research BACKGROUND: Determine the exact slot dimension of a sample of a MBT prescription stainless steel conventional brackets from different manufacturers to compare the actual values with the nominal ones declared by the manufacturers and to verify the compliance with tolerance limits given by the ISO 27020:2019. Different batches from each manufacturer were evaluated to determine whether or not they are different in size. In addition, the geometry of the slot walls was assessed. METHODS: 360 stainless steel preadjusted orthodontic brackets of 12 different manufacturers were assessed. All brackets had a nominal slot size of 0.022 by 0.028 inches, belonged to the right upper central incisor, and were fabricated with the metal injection molding technique (MIM). For each manufacturer, three different manufacturing batches were evaluated. Brackets were coded using a single-blind design. RESULTS: All bracket systems in the study group except one displayed a statistically significant difference with the nominal declared value, although only four of the systems did not comply with the tolerance limits established by the ISO 27020:2019. In most of the systems, the slot height was oversized when compared to the nominal one. A significant interbatch variability was found in most of the evaluated systems. Most of the brackets walls were divergent. CONCLUSIONS: The dimensional accuracy of commercially available metal brackets is not guaranteed. The respect for the norm should be enforced as well as the quality controls along the manufacturing process since orthodontic brackets are a precision medical device. BioMed Central 2021-07-07 /pmc/articles/PMC8261997/ /pubmed/34233698 http://dx.doi.org/10.1186/s13005-021-00276-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Bernés Martínez, Laura
Garcovich, Daniele
España Pamplona, Pilar
Adobes Martín, Milagros Adobes
Alvarado Lorenzo, Alfonso
Compliance with the ISO 27020:2019 norm of a sample of currently available preadjusted Orthodontic bracket systems. Are the actual dimensions as expected?
title Compliance with the ISO 27020:2019 norm of a sample of currently available preadjusted Orthodontic bracket systems. Are the actual dimensions as expected?
title_full Compliance with the ISO 27020:2019 norm of a sample of currently available preadjusted Orthodontic bracket systems. Are the actual dimensions as expected?
title_fullStr Compliance with the ISO 27020:2019 norm of a sample of currently available preadjusted Orthodontic bracket systems. Are the actual dimensions as expected?
title_full_unstemmed Compliance with the ISO 27020:2019 norm of a sample of currently available preadjusted Orthodontic bracket systems. Are the actual dimensions as expected?
title_short Compliance with the ISO 27020:2019 norm of a sample of currently available preadjusted Orthodontic bracket systems. Are the actual dimensions as expected?
title_sort compliance with the iso 27020:2019 norm of a sample of currently available preadjusted orthodontic bracket systems. are the actual dimensions as expected?
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8261997/
https://www.ncbi.nlm.nih.gov/pubmed/34233698
http://dx.doi.org/10.1186/s13005-021-00276-0
work_keys_str_mv AT bernesmartinezlaura compliancewiththeiso270202019normofasampleofcurrentlyavailablepreadjustedorthodonticbracketsystemsaretheactualdimensionsasexpected
AT garcovichdaniele compliancewiththeiso270202019normofasampleofcurrentlyavailablepreadjustedorthodonticbracketsystemsaretheactualdimensionsasexpected
AT espanapamplonapilar compliancewiththeiso270202019normofasampleofcurrentlyavailablepreadjustedorthodonticbracketsystemsaretheactualdimensionsasexpected
AT adobesmartinmilagrosadobes compliancewiththeiso270202019normofasampleofcurrentlyavailablepreadjustedorthodonticbracketsystemsaretheactualdimensionsasexpected
AT alvaradolorenzoalfonso compliancewiththeiso270202019normofasampleofcurrentlyavailablepreadjustedorthodonticbracketsystemsaretheactualdimensionsasexpected