Cargando…
A Novel Thin-Film Technique to Improve Accuracy of Fluorescence-Based Estimates for Periphytic Biofilms
Recent studies suggest that photophysiological parameters for intact substrates with depth (e.g., periphytic biofilms, microphytobenthos) are overestimated by pulse-amplitude modulated (PAM) fluorometry. This overestimation results from depth-integration effects, following the activation of deeper p...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8262624/ https://www.ncbi.nlm.nih.gov/pubmed/34249375 http://dx.doi.org/10.3390/w13111464 |
_version_ | 1783719222472343552 |
---|---|
author | Katona, Leon Vadeboncoeur, Yvonne Nietch, Christopher T. Hossler, Katie |
author_facet | Katona, Leon Vadeboncoeur, Yvonne Nietch, Christopher T. Hossler, Katie |
author_sort | Katona, Leon |
collection | PubMed |
description | Recent studies suggest that photophysiological parameters for intact substrates with depth (e.g., periphytic biofilms, microphytobenthos) are overestimated by pulse-amplitude modulated (PAM) fluorometry. This overestimation results from depth-integration effects, following the activation of deeper photosynthesizing layers by an attenuated light signal. To mitigate this error, we propose a novel slide-based thin-film technique in which fluorescence is measured on a vertically representative subsample of the biofilm, spread evenly on a microscope slide. We compared bias and precision for photosynthetic parameters estimated through conventional PAM fluorometry on intact biofilms and through our novel slide-based technique, both theoretically and empirically. Numerical simulations confirmed the consistent overestimation of key parameters for intact biofilms, with relative errors up to 145%, compared to, at most, 52% on thin films. Paired empirical observations likewise demonstrated that estimates based on intact biofilms were consistently higher (up to 248%, p < 0.001) than estimates from thin films. Numerical simulation suggested greater precision with the slide-based technique for homogeneous biofilms, but potentially less precision for heterogeneous biofilms with improper subsampling. Our empirical comparison, however, demonstrated some improvement in precision with the slide-based technique (e.g., the coefficient of variation for the maximum electron transport rate was reduced 30%, p = 0.009). We recommend the use of the slide-based technique, particularly for biofilms that are thick or have small light attenuation coefficients. Care should be taken, however, to obtain vertically representative subsamples of the biofilm for measurement. |
format | Online Article Text |
id | pubmed-8262624 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
record_format | MEDLINE/PubMed |
spelling | pubmed-82626242022-05-23 A Novel Thin-Film Technique to Improve Accuracy of Fluorescence-Based Estimates for Periphytic Biofilms Katona, Leon Vadeboncoeur, Yvonne Nietch, Christopher T. Hossler, Katie Water (Basel) Article Recent studies suggest that photophysiological parameters for intact substrates with depth (e.g., periphytic biofilms, microphytobenthos) are overestimated by pulse-amplitude modulated (PAM) fluorometry. This overestimation results from depth-integration effects, following the activation of deeper photosynthesizing layers by an attenuated light signal. To mitigate this error, we propose a novel slide-based thin-film technique in which fluorescence is measured on a vertically representative subsample of the biofilm, spread evenly on a microscope slide. We compared bias and precision for photosynthetic parameters estimated through conventional PAM fluorometry on intact biofilms and through our novel slide-based technique, both theoretically and empirically. Numerical simulations confirmed the consistent overestimation of key parameters for intact biofilms, with relative errors up to 145%, compared to, at most, 52% on thin films. Paired empirical observations likewise demonstrated that estimates based on intact biofilms were consistently higher (up to 248%, p < 0.001) than estimates from thin films. Numerical simulation suggested greater precision with the slide-based technique for homogeneous biofilms, but potentially less precision for heterogeneous biofilms with improper subsampling. Our empirical comparison, however, demonstrated some improvement in precision with the slide-based technique (e.g., the coefficient of variation for the maximum electron transport rate was reduced 30%, p = 0.009). We recommend the use of the slide-based technique, particularly for biofilms that are thick or have small light attenuation coefficients. Care should be taken, however, to obtain vertically representative subsamples of the biofilm for measurement. 2021-05-23 /pmc/articles/PMC8262624/ /pubmed/34249375 http://dx.doi.org/10.3390/w13111464 Text en https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Katona, Leon Vadeboncoeur, Yvonne Nietch, Christopher T. Hossler, Katie A Novel Thin-Film Technique to Improve Accuracy of Fluorescence-Based Estimates for Periphytic Biofilms |
title | A Novel Thin-Film Technique to Improve Accuracy of Fluorescence-Based Estimates for Periphytic Biofilms |
title_full | A Novel Thin-Film Technique to Improve Accuracy of Fluorescence-Based Estimates for Periphytic Biofilms |
title_fullStr | A Novel Thin-Film Technique to Improve Accuracy of Fluorescence-Based Estimates for Periphytic Biofilms |
title_full_unstemmed | A Novel Thin-Film Technique to Improve Accuracy of Fluorescence-Based Estimates for Periphytic Biofilms |
title_short | A Novel Thin-Film Technique to Improve Accuracy of Fluorescence-Based Estimates for Periphytic Biofilms |
title_sort | novel thin-film technique to improve accuracy of fluorescence-based estimates for periphytic biofilms |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8262624/ https://www.ncbi.nlm.nih.gov/pubmed/34249375 http://dx.doi.org/10.3390/w13111464 |
work_keys_str_mv | AT katonaleon anovelthinfilmtechniquetoimproveaccuracyoffluorescencebasedestimatesforperiphyticbiofilms AT vadeboncoeuryvonne anovelthinfilmtechniquetoimproveaccuracyoffluorescencebasedestimatesforperiphyticbiofilms AT nietchchristophert anovelthinfilmtechniquetoimproveaccuracyoffluorescencebasedestimatesforperiphyticbiofilms AT hosslerkatie anovelthinfilmtechniquetoimproveaccuracyoffluorescencebasedestimatesforperiphyticbiofilms AT katonaleon novelthinfilmtechniquetoimproveaccuracyoffluorescencebasedestimatesforperiphyticbiofilms AT vadeboncoeuryvonne novelthinfilmtechniquetoimproveaccuracyoffluorescencebasedestimatesforperiphyticbiofilms AT nietchchristophert novelthinfilmtechniquetoimproveaccuracyoffluorescencebasedestimatesforperiphyticbiofilms AT hosslerkatie novelthinfilmtechniquetoimproveaccuracyoffluorescencebasedestimatesforperiphyticbiofilms |