Cargando…
Harmonisation of PET/CT contrast recovery performance for brain studies
PURPOSE: In order to achieve comparability of image quality, harmonisation of PET system performance is imperative. In this study, prototype harmonisation criteria for PET brain studies were developed. METHODS: Twelve clinical PET/CT systems (4 GE, 4 Philips, 4 Siemens, including SiPM-based “digital...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8263427/ https://www.ncbi.nlm.nih.gov/pubmed/33517517 http://dx.doi.org/10.1007/s00259-021-05201-w |
_version_ | 1783719388337143808 |
---|---|
author | Verwer, E. E. Golla, S. S. V. Kaalep, A. Lubberink, M. van Velden, F. H. P. Bettinardi, V. Yaqub, M. Sera, T. Rijnsdorp, S. Lammertsma, A. A. Boellaard, R. |
author_facet | Verwer, E. E. Golla, S. S. V. Kaalep, A. Lubberink, M. van Velden, F. H. P. Bettinardi, V. Yaqub, M. Sera, T. Rijnsdorp, S. Lammertsma, A. A. Boellaard, R. |
author_sort | Verwer, E. E. |
collection | PubMed |
description | PURPOSE: In order to achieve comparability of image quality, harmonisation of PET system performance is imperative. In this study, prototype harmonisation criteria for PET brain studies were developed. METHODS: Twelve clinical PET/CT systems (4 GE, 4 Philips, 4 Siemens, including SiPM-based “digital” systems) were used to acquire 30-min PET scans of a Hoffman 3D Brain phantom filled with ~ 33 kBq·mL(−1) [(18)F]FDG. Scan data were reconstructed using various reconstruction settings. The images were rigidly coregistered to a template (voxel size 1.17 × 1.17 × 2.00 mm(3)) onto which several volumes of interest (VOIs) were defined. Recovery coefficients (RC) and grey matter to white matter ratios (GMWMr) were derived for eroded (denoted in the text by subscript e) and non-eroded grey (GM) and white (WM) matter VOIs as well as a mid-phantom cold spot (VOI(cold)) and VOIs from the Hammers atlas. In addition, left-right hemisphere differences and voxel-by-voxel differences compared to a reference image were assessed. RESULTS: Systematic differences were observed for reconstructions with and without point-spread-function modelling (PSF(ON) and PSF(OFF), respectively). Normalising to image-derived activity, upper and lower limits ensuring image comparability were as follows: for PSF(ON), RC(GMe) = [0.97–1.01] and GMWMr(e) = [3.51–3.91] for eroded VOI and RC(GM) = [0.78–0.83] and GMWMr = [1.77–2.06] for non-eroded VOI, and for PSF(OFF), RC(GMe) = [0.92–0.99] and GMWMr(e) = [3.14–3.68] for eroded VOI and RC(GM) = [0.75–0.81] and GMWMr = [1.72–1.95] for non-eroded VOI. CONCLUSIONS: To achieve inter-scanner comparability, we propose selecting reconstruction settings based on RC(GMe) and GMWMr(e) as specified in “Results”. These proposed standards should be tested prospectively to validate and/or refine the harmonisation criteria. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00259-021-05201-w. |
format | Online Article Text |
id | pubmed-8263427 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-82634272021-07-20 Harmonisation of PET/CT contrast recovery performance for brain studies Verwer, E. E. Golla, S. S. V. Kaalep, A. Lubberink, M. van Velden, F. H. P. Bettinardi, V. Yaqub, M. Sera, T. Rijnsdorp, S. Lammertsma, A. A. Boellaard, R. Eur J Nucl Med Mol Imaging Original Article PURPOSE: In order to achieve comparability of image quality, harmonisation of PET system performance is imperative. In this study, prototype harmonisation criteria for PET brain studies were developed. METHODS: Twelve clinical PET/CT systems (4 GE, 4 Philips, 4 Siemens, including SiPM-based “digital” systems) were used to acquire 30-min PET scans of a Hoffman 3D Brain phantom filled with ~ 33 kBq·mL(−1) [(18)F]FDG. Scan data were reconstructed using various reconstruction settings. The images were rigidly coregistered to a template (voxel size 1.17 × 1.17 × 2.00 mm(3)) onto which several volumes of interest (VOIs) were defined. Recovery coefficients (RC) and grey matter to white matter ratios (GMWMr) were derived for eroded (denoted in the text by subscript e) and non-eroded grey (GM) and white (WM) matter VOIs as well as a mid-phantom cold spot (VOI(cold)) and VOIs from the Hammers atlas. In addition, left-right hemisphere differences and voxel-by-voxel differences compared to a reference image were assessed. RESULTS: Systematic differences were observed for reconstructions with and without point-spread-function modelling (PSF(ON) and PSF(OFF), respectively). Normalising to image-derived activity, upper and lower limits ensuring image comparability were as follows: for PSF(ON), RC(GMe) = [0.97–1.01] and GMWMr(e) = [3.51–3.91] for eroded VOI and RC(GM) = [0.78–0.83] and GMWMr = [1.77–2.06] for non-eroded VOI, and for PSF(OFF), RC(GMe) = [0.92–0.99] and GMWMr(e) = [3.14–3.68] for eroded VOI and RC(GM) = [0.75–0.81] and GMWMr = [1.72–1.95] for non-eroded VOI. CONCLUSIONS: To achieve inter-scanner comparability, we propose selecting reconstruction settings based on RC(GMe) and GMWMr(e) as specified in “Results”. These proposed standards should be tested prospectively to validate and/or refine the harmonisation criteria. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00259-021-05201-w. Springer Berlin Heidelberg 2021-01-31 2021 /pmc/articles/PMC8263427/ /pubmed/33517517 http://dx.doi.org/10.1007/s00259-021-05201-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Verwer, E. E. Golla, S. S. V. Kaalep, A. Lubberink, M. van Velden, F. H. P. Bettinardi, V. Yaqub, M. Sera, T. Rijnsdorp, S. Lammertsma, A. A. Boellaard, R. Harmonisation of PET/CT contrast recovery performance for brain studies |
title | Harmonisation of PET/CT contrast recovery performance for brain studies |
title_full | Harmonisation of PET/CT contrast recovery performance for brain studies |
title_fullStr | Harmonisation of PET/CT contrast recovery performance for brain studies |
title_full_unstemmed | Harmonisation of PET/CT contrast recovery performance for brain studies |
title_short | Harmonisation of PET/CT contrast recovery performance for brain studies |
title_sort | harmonisation of pet/ct contrast recovery performance for brain studies |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8263427/ https://www.ncbi.nlm.nih.gov/pubmed/33517517 http://dx.doi.org/10.1007/s00259-021-05201-w |
work_keys_str_mv | AT verweree harmonisationofpetctcontrastrecoveryperformanceforbrainstudies AT gollassv harmonisationofpetctcontrastrecoveryperformanceforbrainstudies AT kaalepa harmonisationofpetctcontrastrecoveryperformanceforbrainstudies AT lubberinkm harmonisationofpetctcontrastrecoveryperformanceforbrainstudies AT vanveldenfhp harmonisationofpetctcontrastrecoveryperformanceforbrainstudies AT bettinardiv harmonisationofpetctcontrastrecoveryperformanceforbrainstudies AT yaqubm harmonisationofpetctcontrastrecoveryperformanceforbrainstudies AT serat harmonisationofpetctcontrastrecoveryperformanceforbrainstudies AT rijnsdorps harmonisationofpetctcontrastrecoveryperformanceforbrainstudies AT lammertsmaaa harmonisationofpetctcontrastrecoveryperformanceforbrainstudies AT boellaardr harmonisationofpetctcontrastrecoveryperformanceforbrainstudies |