Cargando…
Iliocaval reconstruction of chronically thrombosed cylindrical inferior vena cava filters with balloon expandable covered stent-grafts
The use of a Viabahn VBX endoprosthesis (W. L. Gore & Associates, Flagstaff, Ariz) to exclude chronically thrombosed inferior vena cava (IVC) filters refractory to exclusion with self-expanding stents was evaluated. The mean duration of TrapEase IVC (Cordis, Milpitas, Calif) implantation was 7.6...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8263519/ https://www.ncbi.nlm.nih.gov/pubmed/34278083 http://dx.doi.org/10.1016/j.jvscit.2021.05.006 |
_version_ | 1783719399088193536 |
---|---|
author | Elboraey, Mohamed Toskich, Beau B. Lewis, Andrew R. Ritchie, Charles A. Frey, Gregory T. Devcic, Zlatko |
author_facet | Elboraey, Mohamed Toskich, Beau B. Lewis, Andrew R. Ritchie, Charles A. Frey, Gregory T. Devcic, Zlatko |
author_sort | Elboraey, Mohamed |
collection | PubMed |
description | The use of a Viabahn VBX endoprosthesis (W. L. Gore & Associates, Flagstaff, Ariz) to exclude chronically thrombosed inferior vena cava (IVC) filters refractory to exclusion with self-expanding stents was evaluated. The mean duration of TrapEase IVC (Cordis, Milpitas, Calif) implantation was 7.6 years (range, 2-11 years). Symptoms included leg pain, edema, color changes, and back pain. The mean Villalta score and venous clinical severity score were 17 (range, 13-23) and 13 (range, 11-15), respectively. Indirect ultrasound evidence of stent patency was demonstrated at a mean of 8 months after intervention. The mean Villalta score and venous clinical severity score had decreased by 13 and 10, respectively, at a mean of 9.5 months after intervention. Iliocaval reconstruction with Viabahn VBX balloon expandable stent-graft exclusion of chronically thrombosed TrapEase IVC filters is safe, with favorable short-term results. |
format | Online Article Text |
id | pubmed-8263519 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-82635192021-07-16 Iliocaval reconstruction of chronically thrombosed cylindrical inferior vena cava filters with balloon expandable covered stent-grafts Elboraey, Mohamed Toskich, Beau B. Lewis, Andrew R. Ritchie, Charles A. Frey, Gregory T. Devcic, Zlatko J Vasc Surg Cases Innov Tech Case report The use of a Viabahn VBX endoprosthesis (W. L. Gore & Associates, Flagstaff, Ariz) to exclude chronically thrombosed inferior vena cava (IVC) filters refractory to exclusion with self-expanding stents was evaluated. The mean duration of TrapEase IVC (Cordis, Milpitas, Calif) implantation was 7.6 years (range, 2-11 years). Symptoms included leg pain, edema, color changes, and back pain. The mean Villalta score and venous clinical severity score were 17 (range, 13-23) and 13 (range, 11-15), respectively. Indirect ultrasound evidence of stent patency was demonstrated at a mean of 8 months after intervention. The mean Villalta score and venous clinical severity score had decreased by 13 and 10, respectively, at a mean of 9.5 months after intervention. Iliocaval reconstruction with Viabahn VBX balloon expandable stent-graft exclusion of chronically thrombosed TrapEase IVC filters is safe, with favorable short-term results. Elsevier 2021-05-21 /pmc/articles/PMC8263519/ /pubmed/34278083 http://dx.doi.org/10.1016/j.jvscit.2021.05.006 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case report Elboraey, Mohamed Toskich, Beau B. Lewis, Andrew R. Ritchie, Charles A. Frey, Gregory T. Devcic, Zlatko Iliocaval reconstruction of chronically thrombosed cylindrical inferior vena cava filters with balloon expandable covered stent-grafts |
title | Iliocaval reconstruction of chronically thrombosed cylindrical inferior vena cava filters with balloon expandable covered stent-grafts |
title_full | Iliocaval reconstruction of chronically thrombosed cylindrical inferior vena cava filters with balloon expandable covered stent-grafts |
title_fullStr | Iliocaval reconstruction of chronically thrombosed cylindrical inferior vena cava filters with balloon expandable covered stent-grafts |
title_full_unstemmed | Iliocaval reconstruction of chronically thrombosed cylindrical inferior vena cava filters with balloon expandable covered stent-grafts |
title_short | Iliocaval reconstruction of chronically thrombosed cylindrical inferior vena cava filters with balloon expandable covered stent-grafts |
title_sort | iliocaval reconstruction of chronically thrombosed cylindrical inferior vena cava filters with balloon expandable covered stent-grafts |
topic | Case report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8263519/ https://www.ncbi.nlm.nih.gov/pubmed/34278083 http://dx.doi.org/10.1016/j.jvscit.2021.05.006 |
work_keys_str_mv | AT elboraeymohamed iliocavalreconstructionofchronicallythrombosedcylindricalinferiorvenacavafilterswithballoonexpandablecoveredstentgrafts AT toskichbeaub iliocavalreconstructionofchronicallythrombosedcylindricalinferiorvenacavafilterswithballoonexpandablecoveredstentgrafts AT lewisandrewr iliocavalreconstructionofchronicallythrombosedcylindricalinferiorvenacavafilterswithballoonexpandablecoveredstentgrafts AT ritchiecharlesa iliocavalreconstructionofchronicallythrombosedcylindricalinferiorvenacavafilterswithballoonexpandablecoveredstentgrafts AT freygregoryt iliocavalreconstructionofchronicallythrombosedcylindricalinferiorvenacavafilterswithballoonexpandablecoveredstentgrafts AT devciczlatko iliocavalreconstructionofchronicallythrombosedcylindricalinferiorvenacavafilterswithballoonexpandablecoveredstentgrafts |