In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years

The aim of this study was to quantify and to compare the wear rates of premolar (PM) and molar (M) restorations of lithium disilicate ceramic (LS2) and an experimental CAD/CAM polymer (COMP) in cases of complex rehabilitations with changes in vertical dimension of occlusion (VDO). Twelve patients wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Burian, Gintare, Erdelt, Kurt, Schweiger, Josef, Keul, Christine, Edelhoff, Daniel, Güth, Jan-Frederik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8263767/
https://www.ncbi.nlm.nih.gov/pubmed/34234225
http://dx.doi.org/10.1038/s41598-021-93425-z
_version_ 1783719442757189632
author Burian, Gintare
Erdelt, Kurt
Schweiger, Josef
Keul, Christine
Edelhoff, Daniel
Güth, Jan-Frederik
author_facet Burian, Gintare
Erdelt, Kurt
Schweiger, Josef
Keul, Christine
Edelhoff, Daniel
Güth, Jan-Frederik
author_sort Burian, Gintare
collection PubMed
description The aim of this study was to quantify and to compare the wear rates of premolar (PM) and molar (M) restorations of lithium disilicate ceramic (LS2) and an experimental CAD/CAM polymer (COMP) in cases of complex rehabilitations with changes in vertical dimension of occlusion (VDO). Twelve patients with severe tooth wear underwent prosthetic rehabilitation, restoring the VDO with antagonistic occlusal coverage restorations either out of LS2 (n = 6 patients, n = 16 posterior restorations/patient; N = 96 restorations/year) or COMP (n = 6 patients; n = 16 posterior restorations/patient; N = 96 restorations/year). Data was obtained by digitalization of plaster casts with a laboratory scanner at annual recalls (350 ± 86 days; 755 ± 92 days; 1102 ± 97 days). Each annual recall dataset of premolar and molar restorations (N = 192) was overlaid individually with the corresponding baseline dataset using an iterative best-fit method. Mean vertical loss of the occlusal contact areas (OCAs) was calculated for each restoration and recall time. For LS2 restorations, the mean wear rate per month over 1 year was 7.5 ± 3.4 μm (PM), 7.8 ± 2.0 μm (M), over 2 years 3.8 ± 1.6 µm (PM), 4.4 ± 1.5 µm (M), over 3 years 2.8 ± 1.3 µm (PM), 3.4 ± 1.7 µm (M). For COMP restorations, the mean wear rate per month over 1 year was 15.5 ± 8.9 μm (PM), 28.5 ± 20.2 μm (M), over 2 years 9.2 ± 5.9 µm (PM), 16.7 ± 14.9 µm (M), over 3 years 8.6 ± 5.3 µm (PM), 9.5 ± 8.0 µm (M). Three COMP restorations fractured after two years and therefore were not considered in the 3-year results. The wear rates in the LS2 group showed significant differences between premolars and molars restorations (p = 0.041; p = 0.023; p = 0.045). The wear rates in COMP group differed significantly between premolars and molars only in the first two years (p < 0.0001; p = 0.007). COMP restorations show much higher wear rates compared to LS2. The presented results suggest that with increasing time in situ, the monthly wear rates for both materials decreased over time. On the basis of this limited dataset, both LS2 and COMP restorations show reasonable clinical wear rates after 3 years follow-up. Wear of COMP restorations was higher, however prosthodontic treatment was less invasive. LS2 showed less wear, yet tooth preparation was necessary. Clinicians should balance well between necessary preparation invasiveness and long-term occlusal stability in patients with worn dentitions.
format Online
Article
Text
id pubmed-8263767
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-82637672021-07-09 In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years Burian, Gintare Erdelt, Kurt Schweiger, Josef Keul, Christine Edelhoff, Daniel Güth, Jan-Frederik Sci Rep Article The aim of this study was to quantify and to compare the wear rates of premolar (PM) and molar (M) restorations of lithium disilicate ceramic (LS2) and an experimental CAD/CAM polymer (COMP) in cases of complex rehabilitations with changes in vertical dimension of occlusion (VDO). Twelve patients with severe tooth wear underwent prosthetic rehabilitation, restoring the VDO with antagonistic occlusal coverage restorations either out of LS2 (n = 6 patients, n = 16 posterior restorations/patient; N = 96 restorations/year) or COMP (n = 6 patients; n = 16 posterior restorations/patient; N = 96 restorations/year). Data was obtained by digitalization of plaster casts with a laboratory scanner at annual recalls (350 ± 86 days; 755 ± 92 days; 1102 ± 97 days). Each annual recall dataset of premolar and molar restorations (N = 192) was overlaid individually with the corresponding baseline dataset using an iterative best-fit method. Mean vertical loss of the occlusal contact areas (OCAs) was calculated for each restoration and recall time. For LS2 restorations, the mean wear rate per month over 1 year was 7.5 ± 3.4 μm (PM), 7.8 ± 2.0 μm (M), over 2 years 3.8 ± 1.6 µm (PM), 4.4 ± 1.5 µm (M), over 3 years 2.8 ± 1.3 µm (PM), 3.4 ± 1.7 µm (M). For COMP restorations, the mean wear rate per month over 1 year was 15.5 ± 8.9 μm (PM), 28.5 ± 20.2 μm (M), over 2 years 9.2 ± 5.9 µm (PM), 16.7 ± 14.9 µm (M), over 3 years 8.6 ± 5.3 µm (PM), 9.5 ± 8.0 µm (M). Three COMP restorations fractured after two years and therefore were not considered in the 3-year results. The wear rates in the LS2 group showed significant differences between premolars and molars restorations (p = 0.041; p = 0.023; p = 0.045). The wear rates in COMP group differed significantly between premolars and molars only in the first two years (p < 0.0001; p = 0.007). COMP restorations show much higher wear rates compared to LS2. The presented results suggest that with increasing time in situ, the monthly wear rates for both materials decreased over time. On the basis of this limited dataset, both LS2 and COMP restorations show reasonable clinical wear rates after 3 years follow-up. Wear of COMP restorations was higher, however prosthodontic treatment was less invasive. LS2 showed less wear, yet tooth preparation was necessary. Clinicians should balance well between necessary preparation invasiveness and long-term occlusal stability in patients with worn dentitions. Nature Publishing Group UK 2021-07-07 /pmc/articles/PMC8263767/ /pubmed/34234225 http://dx.doi.org/10.1038/s41598-021-93425-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Burian, Gintare
Erdelt, Kurt
Schweiger, Josef
Keul, Christine
Edelhoff, Daniel
Güth, Jan-Frederik
In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years
title In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years
title_full In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years
title_fullStr In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years
title_full_unstemmed In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years
title_short In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years
title_sort in-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8263767/
https://www.ncbi.nlm.nih.gov/pubmed/34234225
http://dx.doi.org/10.1038/s41598-021-93425-z
work_keys_str_mv AT buriangintare invivowearincompositeandceramicfullmouthrehabilitationsover3years
AT erdeltkurt invivowearincompositeandceramicfullmouthrehabilitationsover3years
AT schweigerjosef invivowearincompositeandceramicfullmouthrehabilitationsover3years
AT keulchristine invivowearincompositeandceramicfullmouthrehabilitationsover3years
AT edelhoffdaniel invivowearincompositeandceramicfullmouthrehabilitationsover3years
AT guthjanfrederik invivowearincompositeandceramicfullmouthrehabilitationsover3years