Cargando…

The Auxiliary Diagnostic Value of a Novel Wearable Electrocardiogram-Recording System for Arrhythmia Detection: Diagnostic Trial

Background: AMAZFIT(®), a novel wearable electrocardiogram (ECG)-recording system is used for the measurement, acquisition, and storage of single-lead cardiac waveforms for adults. The aim of the study was to evaluate the accuracy of AMAZFIT(®) for diagnosing arrhythmia in older patients. Methods: F...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Shaomin, Xian, Hong, Chen, Yi, Liao, Yue, Zhang, Nan, Guo, Xinyu, Yang, Ming, Wu, Jinhui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8264252/
https://www.ncbi.nlm.nih.gov/pubmed/34249976
http://dx.doi.org/10.3389/fmed.2021.685999
_version_ 1783719512401510400
author Zhang, Shaomin
Xian, Hong
Chen, Yi
Liao, Yue
Zhang, Nan
Guo, Xinyu
Yang, Ming
Wu, Jinhui
author_facet Zhang, Shaomin
Xian, Hong
Chen, Yi
Liao, Yue
Zhang, Nan
Guo, Xinyu
Yang, Ming
Wu, Jinhui
author_sort Zhang, Shaomin
collection PubMed
description Background: AMAZFIT(®), a novel wearable electrocardiogram (ECG)-recording system is used for the measurement, acquisition, and storage of single-lead cardiac waveforms for adults. The aim of the study was to evaluate the accuracy of AMAZFIT(®) for diagnosing arrhythmia in older patients. Methods: From May to December 2019, we recruited 291 elderly individuals with an average age of 78±10 years old, and 41.9% women. All cardiac waveforms were obtained from the AMAZFIT(®) which included limb and chest leads. Two trained technicians reviewed all ECG data to determine cardiac rhythm using standard diagnostic criteria. We evaluated the accuracy of AMAZFIT(®) for identifying arrhythmia by comparing the sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), and positive and negative likelihood ratios with those of a standard 12-lead ECG. Results: Of the 291 participants, 197 older adults had arrhythmias, including AF (n = 119), first-degree AVB (n = 28), PACs (n = 25), and PVCs (n = 28). Three of these participants had arrhythmias of AF and PVCs. Chest lead data from 100% and limb lead data from 4.7% of the participants were analyzed. An evaluation of AMAZFIT(®) for atrial fibrillation (AF) reported a sensitivity, specificity, PPV, NPV PLR, and negative likelihood ratio (NLR) of 93.28, 95.35, 93.28, 95.35, 20.06, and 0.07%, respectively. AMAZFIT(®) also demonstrated excellent sensitivity for premature atrial contractions (PACs) (84.00%) and premature ventricular contractions (PVCs) (89.29%). However, the device demonstrated a low sensitivity for first-degree atrioventricular block (32.14%). Conclusions: The AMAZFIT(®) showed significantly higher sensitivity and specificity for AF, PACs, and PVCs. This portable ECG-recording device based on an algorithm has a potential auxiliary diagnostic value for identifying arrhythmia compared with a standard 12-lead ECG device.
format Online
Article
Text
id pubmed-8264252
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-82642522021-07-09 The Auxiliary Diagnostic Value of a Novel Wearable Electrocardiogram-Recording System for Arrhythmia Detection: Diagnostic Trial Zhang, Shaomin Xian, Hong Chen, Yi Liao, Yue Zhang, Nan Guo, Xinyu Yang, Ming Wu, Jinhui Front Med (Lausanne) Medicine Background: AMAZFIT(®), a novel wearable electrocardiogram (ECG)-recording system is used for the measurement, acquisition, and storage of single-lead cardiac waveforms for adults. The aim of the study was to evaluate the accuracy of AMAZFIT(®) for diagnosing arrhythmia in older patients. Methods: From May to December 2019, we recruited 291 elderly individuals with an average age of 78±10 years old, and 41.9% women. All cardiac waveforms were obtained from the AMAZFIT(®) which included limb and chest leads. Two trained technicians reviewed all ECG data to determine cardiac rhythm using standard diagnostic criteria. We evaluated the accuracy of AMAZFIT(®) for identifying arrhythmia by comparing the sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), and positive and negative likelihood ratios with those of a standard 12-lead ECG. Results: Of the 291 participants, 197 older adults had arrhythmias, including AF (n = 119), first-degree AVB (n = 28), PACs (n = 25), and PVCs (n = 28). Three of these participants had arrhythmias of AF and PVCs. Chest lead data from 100% and limb lead data from 4.7% of the participants were analyzed. An evaluation of AMAZFIT(®) for atrial fibrillation (AF) reported a sensitivity, specificity, PPV, NPV PLR, and negative likelihood ratio (NLR) of 93.28, 95.35, 93.28, 95.35, 20.06, and 0.07%, respectively. AMAZFIT(®) also demonstrated excellent sensitivity for premature atrial contractions (PACs) (84.00%) and premature ventricular contractions (PVCs) (89.29%). However, the device demonstrated a low sensitivity for first-degree atrioventricular block (32.14%). Conclusions: The AMAZFIT(®) showed significantly higher sensitivity and specificity for AF, PACs, and PVCs. This portable ECG-recording device based on an algorithm has a potential auxiliary diagnostic value for identifying arrhythmia compared with a standard 12-lead ECG device. Frontiers Media S.A. 2021-06-24 /pmc/articles/PMC8264252/ /pubmed/34249976 http://dx.doi.org/10.3389/fmed.2021.685999 Text en Copyright © 2021 Zhang, Xian, Chen, Liao, Zhang, Guo, Yang and Wu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Zhang, Shaomin
Xian, Hong
Chen, Yi
Liao, Yue
Zhang, Nan
Guo, Xinyu
Yang, Ming
Wu, Jinhui
The Auxiliary Diagnostic Value of a Novel Wearable Electrocardiogram-Recording System for Arrhythmia Detection: Diagnostic Trial
title The Auxiliary Diagnostic Value of a Novel Wearable Electrocardiogram-Recording System for Arrhythmia Detection: Diagnostic Trial
title_full The Auxiliary Diagnostic Value of a Novel Wearable Electrocardiogram-Recording System for Arrhythmia Detection: Diagnostic Trial
title_fullStr The Auxiliary Diagnostic Value of a Novel Wearable Electrocardiogram-Recording System for Arrhythmia Detection: Diagnostic Trial
title_full_unstemmed The Auxiliary Diagnostic Value of a Novel Wearable Electrocardiogram-Recording System for Arrhythmia Detection: Diagnostic Trial
title_short The Auxiliary Diagnostic Value of a Novel Wearable Electrocardiogram-Recording System for Arrhythmia Detection: Diagnostic Trial
title_sort auxiliary diagnostic value of a novel wearable electrocardiogram-recording system for arrhythmia detection: diagnostic trial
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8264252/
https://www.ncbi.nlm.nih.gov/pubmed/34249976
http://dx.doi.org/10.3389/fmed.2021.685999
work_keys_str_mv AT zhangshaomin theauxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT xianhong theauxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT chenyi theauxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT liaoyue theauxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT zhangnan theauxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT guoxinyu theauxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT yangming theauxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT wujinhui theauxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT zhangshaomin auxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT xianhong auxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT chenyi auxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT liaoyue auxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT zhangnan auxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT guoxinyu auxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT yangming auxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial
AT wujinhui auxiliarydiagnosticvalueofanovelwearableelectrocardiogramrecordingsystemforarrhythmiadetectiondiagnostictrial