Cargando…
Case report: Fabrication of a dental implant guide based on tetrahedron positioning technology
BACKGROUND: Conventional static computer-assisted implant surgery (s-CAIS) requires special equipment, such as 3D printers or computer numerical control (CNC) lathes. We present a low-cost workflow for manufacturing dental implant guides based on tetrahedron positioning technology (TPT). The aim of...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8265149/ https://www.ncbi.nlm.nih.gov/pubmed/34233683 http://dx.doi.org/10.1186/s12903-021-01694-x |
_version_ | 1783719712512802816 |
---|---|
author | Lin, Jie Lin, Zhenxiang Zheng, Zhiqiang |
author_facet | Lin, Jie Lin, Zhenxiang Zheng, Zhiqiang |
author_sort | Lin, Jie |
collection | PubMed |
description | BACKGROUND: Conventional static computer-assisted implant surgery (s-CAIS) requires special equipment, such as 3D printers or computer numerical control (CNC) lathes. We present a low-cost workflow for manufacturing dental implant guides based on tetrahedron positioning technology (TPT). The aim of this case report was to use a surgical guide technique for dental implant placement using tetrahedron positioning technology. CASE PRESENTATION: A 28-year-old man consulted for the treatment of a missing right first mandibular molar by implant placement. The cone-beam computed tomography (CBCT) data were imported into medical image processing software for analysis, and the implant design was simulated. The implant design on CBCT was transferred to the mandibular model using TPT, and the implant surgical guide was made to guide the dental implant operation. CBCT was performed postoperatively and compared with the preoperative design to check the accuracy. The central deviation of the implant head was 0.31 mm, the central deviation of the implant apex was 0.93 mm, and the implant angular deviation was 2.45°. CONCLUSION: The use of tetrahedral positioning technology based on CBCT data is a new method for making implant guides. It is a promising technique offering a highly predictable outcome and lower risk of iatrogenic damage. However, these results should be interpreted with care since they are based on limited evidence from a case report. Larger population studies with longer follow-up periods and standardized experimental studies are required. |
format | Online Article Text |
id | pubmed-8265149 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-82651492021-07-08 Case report: Fabrication of a dental implant guide based on tetrahedron positioning technology Lin, Jie Lin, Zhenxiang Zheng, Zhiqiang BMC Oral Health Case Report BACKGROUND: Conventional static computer-assisted implant surgery (s-CAIS) requires special equipment, such as 3D printers or computer numerical control (CNC) lathes. We present a low-cost workflow for manufacturing dental implant guides based on tetrahedron positioning technology (TPT). The aim of this case report was to use a surgical guide technique for dental implant placement using tetrahedron positioning technology. CASE PRESENTATION: A 28-year-old man consulted for the treatment of a missing right first mandibular molar by implant placement. The cone-beam computed tomography (CBCT) data were imported into medical image processing software for analysis, and the implant design was simulated. The implant design on CBCT was transferred to the mandibular model using TPT, and the implant surgical guide was made to guide the dental implant operation. CBCT was performed postoperatively and compared with the preoperative design to check the accuracy. The central deviation of the implant head was 0.31 mm, the central deviation of the implant apex was 0.93 mm, and the implant angular deviation was 2.45°. CONCLUSION: The use of tetrahedral positioning technology based on CBCT data is a new method for making implant guides. It is a promising technique offering a highly predictable outcome and lower risk of iatrogenic damage. However, these results should be interpreted with care since they are based on limited evidence from a case report. Larger population studies with longer follow-up periods and standardized experimental studies are required. BioMed Central 2021-07-07 /pmc/articles/PMC8265149/ /pubmed/34233683 http://dx.doi.org/10.1186/s12903-021-01694-x Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Case Report Lin, Jie Lin, Zhenxiang Zheng, Zhiqiang Case report: Fabrication of a dental implant guide based on tetrahedron positioning technology |
title | Case report: Fabrication of a dental implant guide based on tetrahedron positioning technology |
title_full | Case report: Fabrication of a dental implant guide based on tetrahedron positioning technology |
title_fullStr | Case report: Fabrication of a dental implant guide based on tetrahedron positioning technology |
title_full_unstemmed | Case report: Fabrication of a dental implant guide based on tetrahedron positioning technology |
title_short | Case report: Fabrication of a dental implant guide based on tetrahedron positioning technology |
title_sort | case report: fabrication of a dental implant guide based on tetrahedron positioning technology |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8265149/ https://www.ncbi.nlm.nih.gov/pubmed/34233683 http://dx.doi.org/10.1186/s12903-021-01694-x |
work_keys_str_mv | AT linjie casereportfabricationofadentalimplantguidebasedontetrahedronpositioningtechnology AT linzhenxiang casereportfabricationofadentalimplantguidebasedontetrahedronpositioningtechnology AT zhengzhiqiang casereportfabricationofadentalimplantguidebasedontetrahedronpositioningtechnology |