Accuracy of a Point-of Care Hemoglobin A1c Assay - A Community Outreach Project
Glycated hemoglobin (HbA1c) is an invaluable tool in diabetes mellitus (DM) management. Conventionally obtained via venous blood sampling, point-of-care (POCT) capillary HbA1c measurement offers an opportunity for immediate treatment modification, reduced cost & increased patient satisfaction. W...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8265968/ http://dx.doi.org/10.1210/jendso/bvab048.950 |
_version_ | 1783719842907422720 |
---|---|
author | Semreen, Noura Otuonye, Gene Pena, Angelica Medina Rastogi, Natasha |
author_facet | Semreen, Noura Otuonye, Gene Pena, Angelica Medina Rastogi, Natasha |
author_sort | Semreen, Noura |
collection | PubMed |
description | Glycated hemoglobin (HbA1c) is an invaluable tool in diabetes mellitus (DM) management. Conventionally obtained via venous blood sampling, point-of-care (POCT) capillary HbA1c measurement offers an opportunity for immediate treatment modification, reduced cost & increased patient satisfaction. While previous studies using the POCT HbA1c test A1cNow+ have shown accuracy within a 0.5% range from the gold standard venous HbA1c, we noted discrepancy in our community health clinic & sought to evaluate the accuracy of POCT HbA1c levels compared to venous HbA1c levels to guide our clinical decision-making. In this 2-part study, we compared POCT HbA1c levels measured via a single use A1CNow+ HbA1c monitoring device & venous HbA1c samples measured by a standardized lab. Part1: after retrospective chart review, we identified 262 patients with prediabetes, Type1 or Type2 DM based on ADA guidelines who attended our clinic from January 2019-June 2019 & received POCT HbA1c with A1cNow+ testing during their visit. Of those cases, 47 patients also had a venous HbA1c at a standardized laboratory within 1 month of having their POCT HbA1c performed in our clinic. Part2: We noted variability in the temperature storage of A1CNow+ test strips. Storage was standardized to room temperature as per device instructions in June 2019. We subsequently reviewed charts from June 2019-December 2019 & identified 118 patients who had both POCT HbA1c & venous HbA1c measurement within a 1 month period. Patients was categorized into subgroups per ACP guidelines for DM control: prediabetic (HbA1c 5.7–6.4%), controlled DM (HbA1c 6.5 to 8.0%) & uncontrolled DM (HbA1c >8.0%). The average difference between POCT & venous HbA1c tests was calculated & analyzed for statistical significance using paired t test analysis. Part1: For patients in prediabetic, controlled & uncontrolled DM subgroups, the mean difference between A1cNow+ & standardized venous HbA1c testing was 0.68% (p= 0.004), 1.15% (p= <0.0001) and 1.36% (p= 0.0003) respectively. Part2: After standardization of test strip storage, the mean difference between A1cNow+ & venous HbA1c testing for prediabetic, controlled & uncontrolled DM patients was 0.33% (p= 0.002), 0.41% (p= 0.011) and 1.26% (p= <0.0001) respectively. POCT HbA1c provides a unique opportunity to immediately address glycemic control. Its advantages are especially apparent in a patient population with limited resources & poor follow up, as in our clinic. Although standardizing test storage improved overall concordance between A1cNow+ HbA1c testing & venous HbA1c, there was still a statistically significant larger mean difference in uncontrolled DM patients. In prediabetic & controlled DM patients, however, POCT HbA1c was accurate within previously published reports of a 0.5% range when compared to venous HbA1c. An algorithm has since been developed to guide our clinical decision making with these findings. |
format | Online Article Text |
id | pubmed-8265968 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-82659682021-07-09 Accuracy of a Point-of Care Hemoglobin A1c Assay - A Community Outreach Project Semreen, Noura Otuonye, Gene Pena, Angelica Medina Rastogi, Natasha J Endocr Soc Diabetes Mellitus and Glucose Metabolism Glycated hemoglobin (HbA1c) is an invaluable tool in diabetes mellitus (DM) management. Conventionally obtained via venous blood sampling, point-of-care (POCT) capillary HbA1c measurement offers an opportunity for immediate treatment modification, reduced cost & increased patient satisfaction. While previous studies using the POCT HbA1c test A1cNow+ have shown accuracy within a 0.5% range from the gold standard venous HbA1c, we noted discrepancy in our community health clinic & sought to evaluate the accuracy of POCT HbA1c levels compared to venous HbA1c levels to guide our clinical decision-making. In this 2-part study, we compared POCT HbA1c levels measured via a single use A1CNow+ HbA1c monitoring device & venous HbA1c samples measured by a standardized lab. Part1: after retrospective chart review, we identified 262 patients with prediabetes, Type1 or Type2 DM based on ADA guidelines who attended our clinic from January 2019-June 2019 & received POCT HbA1c with A1cNow+ testing during their visit. Of those cases, 47 patients also had a venous HbA1c at a standardized laboratory within 1 month of having their POCT HbA1c performed in our clinic. Part2: We noted variability in the temperature storage of A1CNow+ test strips. Storage was standardized to room temperature as per device instructions in June 2019. We subsequently reviewed charts from June 2019-December 2019 & identified 118 patients who had both POCT HbA1c & venous HbA1c measurement within a 1 month period. Patients was categorized into subgroups per ACP guidelines for DM control: prediabetic (HbA1c 5.7–6.4%), controlled DM (HbA1c 6.5 to 8.0%) & uncontrolled DM (HbA1c >8.0%). The average difference between POCT & venous HbA1c tests was calculated & analyzed for statistical significance using paired t test analysis. Part1: For patients in prediabetic, controlled & uncontrolled DM subgroups, the mean difference between A1cNow+ & standardized venous HbA1c testing was 0.68% (p= 0.004), 1.15% (p= <0.0001) and 1.36% (p= 0.0003) respectively. Part2: After standardization of test strip storage, the mean difference between A1cNow+ & venous HbA1c testing for prediabetic, controlled & uncontrolled DM patients was 0.33% (p= 0.002), 0.41% (p= 0.011) and 1.26% (p= <0.0001) respectively. POCT HbA1c provides a unique opportunity to immediately address glycemic control. Its advantages are especially apparent in a patient population with limited resources & poor follow up, as in our clinic. Although standardizing test storage improved overall concordance between A1cNow+ HbA1c testing & venous HbA1c, there was still a statistically significant larger mean difference in uncontrolled DM patients. In prediabetic & controlled DM patients, however, POCT HbA1c was accurate within previously published reports of a 0.5% range when compared to venous HbA1c. An algorithm has since been developed to guide our clinical decision making with these findings. Oxford University Press 2021-05-03 /pmc/articles/PMC8265968/ http://dx.doi.org/10.1210/jendso/bvab048.950 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of the Endocrine Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Diabetes Mellitus and Glucose Metabolism Semreen, Noura Otuonye, Gene Pena, Angelica Medina Rastogi, Natasha Accuracy of a Point-of Care Hemoglobin A1c Assay - A Community Outreach Project |
title | Accuracy of a Point-of Care Hemoglobin A1c Assay - A Community Outreach Project |
title_full | Accuracy of a Point-of Care Hemoglobin A1c Assay - A Community Outreach Project |
title_fullStr | Accuracy of a Point-of Care Hemoglobin A1c Assay - A Community Outreach Project |
title_full_unstemmed | Accuracy of a Point-of Care Hemoglobin A1c Assay - A Community Outreach Project |
title_short | Accuracy of a Point-of Care Hemoglobin A1c Assay - A Community Outreach Project |
title_sort | accuracy of a point-of care hemoglobin a1c assay - a community outreach project |
topic | Diabetes Mellitus and Glucose Metabolism |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8265968/ http://dx.doi.org/10.1210/jendso/bvab048.950 |
work_keys_str_mv | AT semreennoura accuracyofapointofcarehemoglobina1cassayacommunityoutreachproject AT otuonyegene accuracyofapointofcarehemoglobina1cassayacommunityoutreachproject AT penaangelicamedina accuracyofapointofcarehemoglobina1cassayacommunityoutreachproject AT rastoginatasha accuracyofapointofcarehemoglobina1cassayacommunityoutreachproject |