Cargando…

Shifting from postauricular to transcanal microscopic tympanoplasty may have similar frequency-specific improvements with better air-bone-gap closure at low frequencies and a minimal learning-curve effect

The shift from postauricular to transcanal microscopic tympanoplasty brings potential advantages of minimal morbidity, less postoperative pain, patient comfort, and surgical ease and speed, but also uncertainties of unfamiliar grafting material, an inadequate operation view, and an uncertain learnin...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Ethan I., Wu, Yu-Chieh, Chuang, Hsiu-Mei, Huang, Tzu-Chi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8266074/
https://www.ncbi.nlm.nih.gov/pubmed/34237091
http://dx.doi.org/10.1371/journal.pone.0253947
_version_ 1783719866905133056
author Huang, Ethan I.
Wu, Yu-Chieh
Chuang, Hsiu-Mei
Huang, Tzu-Chi
author_facet Huang, Ethan I.
Wu, Yu-Chieh
Chuang, Hsiu-Mei
Huang, Tzu-Chi
author_sort Huang, Ethan I.
collection PubMed
description The shift from postauricular to transcanal microscopic tympanoplasty brings potential advantages of minimal morbidity, less postoperative pain, patient comfort, and surgical ease and speed, but also uncertainties of unfamiliar grafting material, an inadequate operation view, and an uncertain learning curve. These challenges might affect the successful repair rate and the frequency-specific hearing outcome, which is important for hearing perception. Rare studies reported frequency-specific hearing outcome with the learning curve for shifting from postauricular to transcanal microscopic tympanoplasty. Here, from Jul. 2013 to Nov. 2018, we compared patients in a shift from postauricular approach (35 ears) to transcanal approach (35 ears) of microscopic type-1 tympanoplasty. The results show that both of postauricular and transcanal microscopic tympanoplasties reduced the mean air-bone gap, 0.5k Hz gap, and 1k Hz gap after the surgery. The further analyses on gap change as a function of frequency (0.5, 1, 2, and 4k Hz) show that both of postauricular and transcanal tympanoplasties improved postoperative air-bone gap among the levels of frequency. The post hoc comparisons display a common gap reduction difference between 0.5k and 4k Hz. The successful repair rate did not differ between the 2 groups. There was no correlation between the postoperative mean gap change and the surgery date, suggesting a minimal learning-curve effect. The results of similar frequency-specific improvements and a minimal learning-curve effect may help to ease the concerns of those uncertainties before the shift.
format Online
Article
Text
id pubmed-8266074
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-82660742021-07-19 Shifting from postauricular to transcanal microscopic tympanoplasty may have similar frequency-specific improvements with better air-bone-gap closure at low frequencies and a minimal learning-curve effect Huang, Ethan I. Wu, Yu-Chieh Chuang, Hsiu-Mei Huang, Tzu-Chi PLoS One Research Article The shift from postauricular to transcanal microscopic tympanoplasty brings potential advantages of minimal morbidity, less postoperative pain, patient comfort, and surgical ease and speed, but also uncertainties of unfamiliar grafting material, an inadequate operation view, and an uncertain learning curve. These challenges might affect the successful repair rate and the frequency-specific hearing outcome, which is important for hearing perception. Rare studies reported frequency-specific hearing outcome with the learning curve for shifting from postauricular to transcanal microscopic tympanoplasty. Here, from Jul. 2013 to Nov. 2018, we compared patients in a shift from postauricular approach (35 ears) to transcanal approach (35 ears) of microscopic type-1 tympanoplasty. The results show that both of postauricular and transcanal microscopic tympanoplasties reduced the mean air-bone gap, 0.5k Hz gap, and 1k Hz gap after the surgery. The further analyses on gap change as a function of frequency (0.5, 1, 2, and 4k Hz) show that both of postauricular and transcanal tympanoplasties improved postoperative air-bone gap among the levels of frequency. The post hoc comparisons display a common gap reduction difference between 0.5k and 4k Hz. The successful repair rate did not differ between the 2 groups. There was no correlation between the postoperative mean gap change and the surgery date, suggesting a minimal learning-curve effect. The results of similar frequency-specific improvements and a minimal learning-curve effect may help to ease the concerns of those uncertainties before the shift. Public Library of Science 2021-07-08 /pmc/articles/PMC8266074/ /pubmed/34237091 http://dx.doi.org/10.1371/journal.pone.0253947 Text en © 2021 Huang et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Huang, Ethan I.
Wu, Yu-Chieh
Chuang, Hsiu-Mei
Huang, Tzu-Chi
Shifting from postauricular to transcanal microscopic tympanoplasty may have similar frequency-specific improvements with better air-bone-gap closure at low frequencies and a minimal learning-curve effect
title Shifting from postauricular to transcanal microscopic tympanoplasty may have similar frequency-specific improvements with better air-bone-gap closure at low frequencies and a minimal learning-curve effect
title_full Shifting from postauricular to transcanal microscopic tympanoplasty may have similar frequency-specific improvements with better air-bone-gap closure at low frequencies and a minimal learning-curve effect
title_fullStr Shifting from postauricular to transcanal microscopic tympanoplasty may have similar frequency-specific improvements with better air-bone-gap closure at low frequencies and a minimal learning-curve effect
title_full_unstemmed Shifting from postauricular to transcanal microscopic tympanoplasty may have similar frequency-specific improvements with better air-bone-gap closure at low frequencies and a minimal learning-curve effect
title_short Shifting from postauricular to transcanal microscopic tympanoplasty may have similar frequency-specific improvements with better air-bone-gap closure at low frequencies and a minimal learning-curve effect
title_sort shifting from postauricular to transcanal microscopic tympanoplasty may have similar frequency-specific improvements with better air-bone-gap closure at low frequencies and a minimal learning-curve effect
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8266074/
https://www.ncbi.nlm.nih.gov/pubmed/34237091
http://dx.doi.org/10.1371/journal.pone.0253947
work_keys_str_mv AT huangethani shiftingfrompostauriculartotranscanalmicroscopictympanoplastymayhavesimilarfrequencyspecificimprovementswithbetterairbonegapclosureatlowfrequenciesandaminimallearningcurveeffect
AT wuyuchieh shiftingfrompostauriculartotranscanalmicroscopictympanoplastymayhavesimilarfrequencyspecificimprovementswithbetterairbonegapclosureatlowfrequenciesandaminimallearningcurveeffect
AT chuanghsiumei shiftingfrompostauriculartotranscanalmicroscopictympanoplastymayhavesimilarfrequencyspecificimprovementswithbetterairbonegapclosureatlowfrequenciesandaminimallearningcurveeffect
AT huangtzuchi shiftingfrompostauriculartotranscanalmicroscopictympanoplastymayhavesimilarfrequencyspecificimprovementswithbetterairbonegapclosureatlowfrequenciesandaminimallearningcurveeffect