Cargando…

Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis

Aim. To conduct a systematic review and meta-analysis according to the following PICO question: in extracted human permanent teeth, does preflaring, compared with unflared canals, influence the accuracy of WL determination with EAL? Material and Methods. A systematic review was conducted according t...

Descripción completa

Detalles Bibliográficos
Autores principales: León-López, María, Cabanillas-Balsera, Daniel, Areal-Quecuty, Victoria, Martín-González, Jenifer, Jiménez-Sánchez, María C., Saúco-Márquez, Juan J., Sánchez-Domínguez, Benito, Segura-Egea, Juan J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8268739/
https://www.ncbi.nlm.nih.gov/pubmed/34201705
http://dx.doi.org/10.3390/jcm10132760
_version_ 1783720424137293824
author León-López, María
Cabanillas-Balsera, Daniel
Areal-Quecuty, Victoria
Martín-González, Jenifer
Jiménez-Sánchez, María C.
Saúco-Márquez, Juan J.
Sánchez-Domínguez, Benito
Segura-Egea, Juan J.
author_facet León-López, María
Cabanillas-Balsera, Daniel
Areal-Quecuty, Victoria
Martín-González, Jenifer
Jiménez-Sánchez, María C.
Saúco-Márquez, Juan J.
Sánchez-Domínguez, Benito
Segura-Egea, Juan J.
author_sort León-López, María
collection PubMed
description Aim. To conduct a systematic review and meta-analysis according to the following PICO question: in extracted human permanent teeth, does preflaring, compared with unflared canals, influence the accuracy of WL determination with EAL? Material and Methods. A systematic review was conducted according to the PRISMA checklist, using the following databases: PubMed, Science Direct, Scopus, and Web of Science. Studies related to WL determination using EAL both in preflared and unflared root canals of extracted human teeth were included. The outcome of interest was the accuracy of the electronic WL determination. A quality assessment of the included studies was performed, determining the risk of bias. The meta-analyses were calculated with the 5.4 RevMan software using the inverse variance method with random effects. PROSPERO registration: CRD42021243412. Results. Ten experimental studies fulfilled the inclusion criteria, and most of them found that preflaring increases the accuracy of the EALs in WL determination. The calculated OR was 1.98 (95% CI = 1.65–2.37; p < 0.00001; I(2) = 10%), indicating that the determination of WL by EALs is almost twice as accurate in preflared canals. The accuracy of Root ZX in WL determination increases more than three times (OR = 3.25; p < 0.00001). Preflaring with Protaper files significantly increases the accuracy of EALs (OR = 1.76; p < 0.00001). The total risk of bias of the included studies was low. No obvious publication bias was observed. Conclusions. The results indicate a significant increase in the accuracy of WL determination with EAL after preflaring, doubling the percentage of exact measurements. Preflaring should be recommended as an important step during mechanical enlargement of the root canal, not only because it improves the access of the files to the canal, but also because it allows one to obtain more accurate electronic determinations of WL.
format Online
Article
Text
id pubmed-8268739
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82687392021-07-10 Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis León-López, María Cabanillas-Balsera, Daniel Areal-Quecuty, Victoria Martín-González, Jenifer Jiménez-Sánchez, María C. Saúco-Márquez, Juan J. Sánchez-Domínguez, Benito Segura-Egea, Juan J. J Clin Med Review Aim. To conduct a systematic review and meta-analysis according to the following PICO question: in extracted human permanent teeth, does preflaring, compared with unflared canals, influence the accuracy of WL determination with EAL? Material and Methods. A systematic review was conducted according to the PRISMA checklist, using the following databases: PubMed, Science Direct, Scopus, and Web of Science. Studies related to WL determination using EAL both in preflared and unflared root canals of extracted human teeth were included. The outcome of interest was the accuracy of the electronic WL determination. A quality assessment of the included studies was performed, determining the risk of bias. The meta-analyses were calculated with the 5.4 RevMan software using the inverse variance method with random effects. PROSPERO registration: CRD42021243412. Results. Ten experimental studies fulfilled the inclusion criteria, and most of them found that preflaring increases the accuracy of the EALs in WL determination. The calculated OR was 1.98 (95% CI = 1.65–2.37; p < 0.00001; I(2) = 10%), indicating that the determination of WL by EALs is almost twice as accurate in preflared canals. The accuracy of Root ZX in WL determination increases more than three times (OR = 3.25; p < 0.00001). Preflaring with Protaper files significantly increases the accuracy of EALs (OR = 1.76; p < 0.00001). The total risk of bias of the included studies was low. No obvious publication bias was observed. Conclusions. The results indicate a significant increase in the accuracy of WL determination with EAL after preflaring, doubling the percentage of exact measurements. Preflaring should be recommended as an important step during mechanical enlargement of the root canal, not only because it improves the access of the files to the canal, but also because it allows one to obtain more accurate electronic determinations of WL. MDPI 2021-06-23 /pmc/articles/PMC8268739/ /pubmed/34201705 http://dx.doi.org/10.3390/jcm10132760 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
León-López, María
Cabanillas-Balsera, Daniel
Areal-Quecuty, Victoria
Martín-González, Jenifer
Jiménez-Sánchez, María C.
Saúco-Márquez, Juan J.
Sánchez-Domínguez, Benito
Segura-Egea, Juan J.
Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis
title Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis
title_full Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis
title_fullStr Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis
title_full_unstemmed Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis
title_short Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis
title_sort influence of coronal preflaring on the accuracy of electronic working length determination: systematic review and meta-analysis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8268739/
https://www.ncbi.nlm.nih.gov/pubmed/34201705
http://dx.doi.org/10.3390/jcm10132760
work_keys_str_mv AT leonlopezmaria influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis
AT cabanillasbalseradaniel influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis
AT arealquecutyvictoria influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis
AT martingonzalezjenifer influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis
AT jimenezsanchezmariac influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis
AT saucomarquezjuanj influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis
AT sanchezdominguezbenito influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis
AT seguraegeajuanj influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis