Cargando…

Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study

To verify the influence of platform-switching (PS) on soft tissue behavior by comparing the soft tissue stability around implants with and without PS, during three years of follow-up. The study included patients treated with fixed dentures supported by implants with an internal connection. The radio...

Descripción completa

Detalles Bibliográficos
Autores principales: Farronato, Davide, Manfredini, Mattia, Farronato, Marco, Pasini, Pietro Mario, Orsina, Andrea Alain, Lops, Diego
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8269426/
https://www.ncbi.nlm.nih.gov/pubmed/34209354
http://dx.doi.org/10.3390/jcm10132955
_version_ 1783720577185349632
author Farronato, Davide
Manfredini, Mattia
Farronato, Marco
Pasini, Pietro Mario
Orsina, Andrea Alain
Lops, Diego
author_facet Farronato, Davide
Manfredini, Mattia
Farronato, Marco
Pasini, Pietro Mario
Orsina, Andrea Alain
Lops, Diego
author_sort Farronato, Davide
collection PubMed
description To verify the influence of platform-switching (PS) on soft tissue behavior by comparing the soft tissue stability around implants with and without PS, during three years of follow-up. The study included patients treated with fixed dentures supported by implants with an internal connection. The radiographic distance between the first bone-to-implant contact (FBIC) and the implant shoulder was assessed. Additionally, the presence of keratinized facial mucosa and the prosthetic crown height (TH) were monitored for three years from the delivery of the definitive crown. These parameters were measured for two different groups: platform-switched implants in the PS group and non-platform-switched (NPS) implants in the NPS group. Seventy-seven implants were considered in the statistical analysis. After three years, the overall FBIC mean value was 0.31 ± 1.00 mm. However, the mean FBIC was 0.66 ± 0.97 mm for the NPS group and −0.05 ± 0.91 mm for the PS group. Moreover, a mean recession of 0.54 ± 1.39 mm was measured for the NPS group, whereas a mean coronal migration of 0.17 ± 0.95 mm was measured for the PS group. A significant correlation was also found between the presence of PS and ΔTH (p ≤ 0.01) over the three years of follow-up. The absence or presence of platform-switching would appear to affect the tendency of the gingival buccal margin towards recession or creeping. Additionally, implant-abutment platform-switching seems to help prevent peri-implant soft tissue recession over time when compared to implants without PS.
format Online
Article
Text
id pubmed-8269426
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82694262021-07-10 Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study Farronato, Davide Manfredini, Mattia Farronato, Marco Pasini, Pietro Mario Orsina, Andrea Alain Lops, Diego J Clin Med Article To verify the influence of platform-switching (PS) on soft tissue behavior by comparing the soft tissue stability around implants with and without PS, during three years of follow-up. The study included patients treated with fixed dentures supported by implants with an internal connection. The radiographic distance between the first bone-to-implant contact (FBIC) and the implant shoulder was assessed. Additionally, the presence of keratinized facial mucosa and the prosthetic crown height (TH) were monitored for three years from the delivery of the definitive crown. These parameters were measured for two different groups: platform-switched implants in the PS group and non-platform-switched (NPS) implants in the NPS group. Seventy-seven implants were considered in the statistical analysis. After three years, the overall FBIC mean value was 0.31 ± 1.00 mm. However, the mean FBIC was 0.66 ± 0.97 mm for the NPS group and −0.05 ± 0.91 mm for the PS group. Moreover, a mean recession of 0.54 ± 1.39 mm was measured for the NPS group, whereas a mean coronal migration of 0.17 ± 0.95 mm was measured for the PS group. A significant correlation was also found between the presence of PS and ΔTH (p ≤ 0.01) over the three years of follow-up. The absence or presence of platform-switching would appear to affect the tendency of the gingival buccal margin towards recession or creeping. Additionally, implant-abutment platform-switching seems to help prevent peri-implant soft tissue recession over time when compared to implants without PS. MDPI 2021-06-30 /pmc/articles/PMC8269426/ /pubmed/34209354 http://dx.doi.org/10.3390/jcm10132955 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Farronato, Davide
Manfredini, Mattia
Farronato, Marco
Pasini, Pietro Mario
Orsina, Andrea Alain
Lops, Diego
Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study
title Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study
title_full Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study
title_fullStr Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study
title_full_unstemmed Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study
title_short Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study
title_sort behavior of soft tissue around platform-switched implants and non-platform-switched implants: a comparative three-year clinical study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8269426/
https://www.ncbi.nlm.nih.gov/pubmed/34209354
http://dx.doi.org/10.3390/jcm10132955
work_keys_str_mv AT farronatodavide behaviorofsofttissuearoundplatformswitchedimplantsandnonplatformswitchedimplantsacomparativethreeyearclinicalstudy
AT manfredinimattia behaviorofsofttissuearoundplatformswitchedimplantsandnonplatformswitchedimplantsacomparativethreeyearclinicalstudy
AT farronatomarco behaviorofsofttissuearoundplatformswitchedimplantsandnonplatformswitchedimplantsacomparativethreeyearclinicalstudy
AT pasinipietromario behaviorofsofttissuearoundplatformswitchedimplantsandnonplatformswitchedimplantsacomparativethreeyearclinicalstudy
AT orsinaandreaalain behaviorofsofttissuearoundplatformswitchedimplantsandnonplatformswitchedimplantsacomparativethreeyearclinicalstudy
AT lopsdiego behaviorofsofttissuearoundplatformswitchedimplantsandnonplatformswitchedimplantsacomparativethreeyearclinicalstudy