Cargando…
Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study
To verify the influence of platform-switching (PS) on soft tissue behavior by comparing the soft tissue stability around implants with and without PS, during three years of follow-up. The study included patients treated with fixed dentures supported by implants with an internal connection. The radio...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8269426/ https://www.ncbi.nlm.nih.gov/pubmed/34209354 http://dx.doi.org/10.3390/jcm10132955 |
_version_ | 1783720577185349632 |
---|---|
author | Farronato, Davide Manfredini, Mattia Farronato, Marco Pasini, Pietro Mario Orsina, Andrea Alain Lops, Diego |
author_facet | Farronato, Davide Manfredini, Mattia Farronato, Marco Pasini, Pietro Mario Orsina, Andrea Alain Lops, Diego |
author_sort | Farronato, Davide |
collection | PubMed |
description | To verify the influence of platform-switching (PS) on soft tissue behavior by comparing the soft tissue stability around implants with and without PS, during three years of follow-up. The study included patients treated with fixed dentures supported by implants with an internal connection. The radiographic distance between the first bone-to-implant contact (FBIC) and the implant shoulder was assessed. Additionally, the presence of keratinized facial mucosa and the prosthetic crown height (TH) were monitored for three years from the delivery of the definitive crown. These parameters were measured for two different groups: platform-switched implants in the PS group and non-platform-switched (NPS) implants in the NPS group. Seventy-seven implants were considered in the statistical analysis. After three years, the overall FBIC mean value was 0.31 ± 1.00 mm. However, the mean FBIC was 0.66 ± 0.97 mm for the NPS group and −0.05 ± 0.91 mm for the PS group. Moreover, a mean recession of 0.54 ± 1.39 mm was measured for the NPS group, whereas a mean coronal migration of 0.17 ± 0.95 mm was measured for the PS group. A significant correlation was also found between the presence of PS and ΔTH (p ≤ 0.01) over the three years of follow-up. The absence or presence of platform-switching would appear to affect the tendency of the gingival buccal margin towards recession or creeping. Additionally, implant-abutment platform-switching seems to help prevent peri-implant soft tissue recession over time when compared to implants without PS. |
format | Online Article Text |
id | pubmed-8269426 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-82694262021-07-10 Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study Farronato, Davide Manfredini, Mattia Farronato, Marco Pasini, Pietro Mario Orsina, Andrea Alain Lops, Diego J Clin Med Article To verify the influence of platform-switching (PS) on soft tissue behavior by comparing the soft tissue stability around implants with and without PS, during three years of follow-up. The study included patients treated with fixed dentures supported by implants with an internal connection. The radiographic distance between the first bone-to-implant contact (FBIC) and the implant shoulder was assessed. Additionally, the presence of keratinized facial mucosa and the prosthetic crown height (TH) were monitored for three years from the delivery of the definitive crown. These parameters were measured for two different groups: platform-switched implants in the PS group and non-platform-switched (NPS) implants in the NPS group. Seventy-seven implants were considered in the statistical analysis. After three years, the overall FBIC mean value was 0.31 ± 1.00 mm. However, the mean FBIC was 0.66 ± 0.97 mm for the NPS group and −0.05 ± 0.91 mm for the PS group. Moreover, a mean recession of 0.54 ± 1.39 mm was measured for the NPS group, whereas a mean coronal migration of 0.17 ± 0.95 mm was measured for the PS group. A significant correlation was also found between the presence of PS and ΔTH (p ≤ 0.01) over the three years of follow-up. The absence or presence of platform-switching would appear to affect the tendency of the gingival buccal margin towards recession or creeping. Additionally, implant-abutment platform-switching seems to help prevent peri-implant soft tissue recession over time when compared to implants without PS. MDPI 2021-06-30 /pmc/articles/PMC8269426/ /pubmed/34209354 http://dx.doi.org/10.3390/jcm10132955 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Farronato, Davide Manfredini, Mattia Farronato, Marco Pasini, Pietro Mario Orsina, Andrea Alain Lops, Diego Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study |
title | Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study |
title_full | Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study |
title_fullStr | Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study |
title_full_unstemmed | Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study |
title_short | Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study |
title_sort | behavior of soft tissue around platform-switched implants and non-platform-switched implants: a comparative three-year clinical study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8269426/ https://www.ncbi.nlm.nih.gov/pubmed/34209354 http://dx.doi.org/10.3390/jcm10132955 |
work_keys_str_mv | AT farronatodavide behaviorofsofttissuearoundplatformswitchedimplantsandnonplatformswitchedimplantsacomparativethreeyearclinicalstudy AT manfredinimattia behaviorofsofttissuearoundplatformswitchedimplantsandnonplatformswitchedimplantsacomparativethreeyearclinicalstudy AT farronatomarco behaviorofsofttissuearoundplatformswitchedimplantsandnonplatformswitchedimplantsacomparativethreeyearclinicalstudy AT pasinipietromario behaviorofsofttissuearoundplatformswitchedimplantsandnonplatformswitchedimplantsacomparativethreeyearclinicalstudy AT orsinaandreaalain behaviorofsofttissuearoundplatformswitchedimplantsandnonplatformswitchedimplantsacomparativethreeyearclinicalstudy AT lopsdiego behaviorofsofttissuearoundplatformswitchedimplantsandnonplatformswitchedimplantsacomparativethreeyearclinicalstudy |