Cargando…

Safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia

OBJECTIVE: Hypoglycemia increases the risk of adverse neurological outcomes in neonates. Adequate glucose monitoring requires repetitive and painful blood sampling. We aimed to evaluate the feasibility and accuracy of a continuous glucose monitoring system (CGMS) using factory-calibrated sensors to...

Descripción completa

Detalles Bibliográficos
Autores principales: Nishimura, Eri, Oka, Shuntaro, Ozawa, Junichi, Tanaka, Kosuke, Momose, Taichi, Kabe, Kazuhiko, Namba, Fumihiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Turkish Pediatric Association 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8269939/
https://www.ncbi.nlm.nih.gov/pubmed/34286319
http://dx.doi.org/10.5152/TurkArchPediatr.2020.20183
_version_ 1783720697857572864
author Nishimura, Eri
Oka, Shuntaro
Ozawa, Junichi
Tanaka, Kosuke
Momose, Taichi
Kabe, Kazuhiko
Namba, Fumihiko
author_facet Nishimura, Eri
Oka, Shuntaro
Ozawa, Junichi
Tanaka, Kosuke
Momose, Taichi
Kabe, Kazuhiko
Namba, Fumihiko
author_sort Nishimura, Eri
collection PubMed
description OBJECTIVE: Hypoglycemia increases the risk of adverse neurological outcomes in neonates. Adequate glucose monitoring requires repetitive and painful blood sampling. We aimed to evaluate the feasibility and accuracy of a continuous glucose monitoring system (CGMS) using factory-calibrated sensors to improve glucose monitoring and decrease the frequency of blood samples in neonates. MATERIAL AND METHODS: A methodological study was conducted to investigate a correlation of CGMS values with blood glucose measurements. RESULTS: Factory-calibrated CGMS sensors were placed on 21 infants at risk of hypoglycemia after delivery. CGMS values were compared with blood glucose concentrations. Thirty-seven pairs of CGMS and blood glucose values were obtained. There was a good correlation between CGMS and blood glucose values (R=0.67, p<0.01) with a mean difference (2 standard deviations) of 9.78 (−24.68 to 44.25) mg/dL. The mean differences at <3 hours and ≥3 hours after sensor placement were 17.35 (−4.54 to 39.21) mg/dL and 0.88 (−37.62 to 39.38) mg/dL, respectively. CGMS values were significantly higher than blood glucose concentration at <3 hours after sensor placement (p<0.01), whereas no significant differences in glucose values were observed between the CGMS and blood glucose values at ≥3 hours after sensor placement (p=0.852). CONCLUSION: The factory-calibrated CGMS was a safe and feasible modality for glucose monitoring. However, it has a tendency to overestimate the blood glucose concentrations. Therefore, this system should be used cautiously for neonates at risk of hypoglycemia, especially within 3 hours after sensor placement.
format Online
Article
Text
id pubmed-8269939
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Turkish Pediatric Association
record_format MEDLINE/PubMed
spelling pubmed-82699392021-07-19 Safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia Nishimura, Eri Oka, Shuntaro Ozawa, Junichi Tanaka, Kosuke Momose, Taichi Kabe, Kazuhiko Namba, Fumihiko Turk Arch Pediatr Original Article OBJECTIVE: Hypoglycemia increases the risk of adverse neurological outcomes in neonates. Adequate glucose monitoring requires repetitive and painful blood sampling. We aimed to evaluate the feasibility and accuracy of a continuous glucose monitoring system (CGMS) using factory-calibrated sensors to improve glucose monitoring and decrease the frequency of blood samples in neonates. MATERIAL AND METHODS: A methodological study was conducted to investigate a correlation of CGMS values with blood glucose measurements. RESULTS: Factory-calibrated CGMS sensors were placed on 21 infants at risk of hypoglycemia after delivery. CGMS values were compared with blood glucose concentrations. Thirty-seven pairs of CGMS and blood glucose values were obtained. There was a good correlation between CGMS and blood glucose values (R=0.67, p<0.01) with a mean difference (2 standard deviations) of 9.78 (−24.68 to 44.25) mg/dL. The mean differences at <3 hours and ≥3 hours after sensor placement were 17.35 (−4.54 to 39.21) mg/dL and 0.88 (−37.62 to 39.38) mg/dL, respectively. CGMS values were significantly higher than blood glucose concentration at <3 hours after sensor placement (p<0.01), whereas no significant differences in glucose values were observed between the CGMS and blood glucose values at ≥3 hours after sensor placement (p=0.852). CONCLUSION: The factory-calibrated CGMS was a safe and feasible modality for glucose monitoring. However, it has a tendency to overestimate the blood glucose concentrations. Therefore, this system should be used cautiously for neonates at risk of hypoglycemia, especially within 3 hours after sensor placement. Turkish Pediatric Association 2021-01-12 /pmc/articles/PMC8269939/ /pubmed/34286319 http://dx.doi.org/10.5152/TurkArchPediatr.2020.20183 Text en Copyright © 2021 Turkish Pediatric Association https://creativecommons.org/licenses/by-nc/4.0/Content of this journal is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
spellingShingle Original Article
Nishimura, Eri
Oka, Shuntaro
Ozawa, Junichi
Tanaka, Kosuke
Momose, Taichi
Kabe, Kazuhiko
Namba, Fumihiko
Safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia
title Safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia
title_full Safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia
title_fullStr Safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia
title_full_unstemmed Safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia
title_short Safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia
title_sort safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8269939/
https://www.ncbi.nlm.nih.gov/pubmed/34286319
http://dx.doi.org/10.5152/TurkArchPediatr.2020.20183
work_keys_str_mv AT nishimuraeri safetyandfeasibilityofafactorycalibratedcontinuousglucosemonitoringsystemintermandnearterminfantsatriskofhypoglycemia
AT okashuntaro safetyandfeasibilityofafactorycalibratedcontinuousglucosemonitoringsystemintermandnearterminfantsatriskofhypoglycemia
AT ozawajunichi safetyandfeasibilityofafactorycalibratedcontinuousglucosemonitoringsystemintermandnearterminfantsatriskofhypoglycemia
AT tanakakosuke safetyandfeasibilityofafactorycalibratedcontinuousglucosemonitoringsystemintermandnearterminfantsatriskofhypoglycemia
AT momosetaichi safetyandfeasibilityofafactorycalibratedcontinuousglucosemonitoringsystemintermandnearterminfantsatriskofhypoglycemia
AT kabekazuhiko safetyandfeasibilityofafactorycalibratedcontinuousglucosemonitoringsystemintermandnearterminfantsatriskofhypoglycemia
AT nambafumihiko safetyandfeasibilityofafactorycalibratedcontinuousglucosemonitoringsystemintermandnearterminfantsatriskofhypoglycemia