Cargando…

Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration

Accurate dynamic pressure measurements are increasingly important. While traceability is lacking, several National Metrology Institutes (NMIs) and calibration laboratories are currently establishing calibration capacities. Shock tubes generating pressure steps with rise times below 1 μs are highly s...

Descripción completa

Detalles Bibliográficos
Autores principales: Amer, Eynas, Wozniak, Mikolaj, Jönsson, Gustav, Arrhén, Fredrik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8271782/
https://www.ncbi.nlm.nih.gov/pubmed/34210071
http://dx.doi.org/10.3390/s21134470
_version_ 1783721073057988608
author Amer, Eynas
Wozniak, Mikolaj
Jönsson, Gustav
Arrhén, Fredrik
author_facet Amer, Eynas
Wozniak, Mikolaj
Jönsson, Gustav
Arrhén, Fredrik
author_sort Amer, Eynas
collection PubMed
description Accurate dynamic pressure measurements are increasingly important. While traceability is lacking, several National Metrology Institutes (NMIs) and calibration laboratories are currently establishing calibration capacities. Shock tubes generating pressure steps with rise times below 1 μs are highly suitable as standards for dynamic pressures in gas. In this work, we present the results from applying a fast-opening valve (FOV) to a shock tube designed for dynamic pressure measurements. We compare the performance of the shock tube when operated with conventional single and double diaphragms and when operated using an FOV. Different aspects are addressed: shock-wave formation, repeatability in amplitude of the realized pressure steps, the assessment of the required driver pressure for realizing nominal pressure steps, and economy. The results show that using the FOV has many advantages compared to the diaphragm: better repeatability, eight times faster to operate, and enables automation of the test sequences.
format Online
Article
Text
id pubmed-8271782
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82717822021-07-11 Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration Amer, Eynas Wozniak, Mikolaj Jönsson, Gustav Arrhén, Fredrik Sensors (Basel) Communication Accurate dynamic pressure measurements are increasingly important. While traceability is lacking, several National Metrology Institutes (NMIs) and calibration laboratories are currently establishing calibration capacities. Shock tubes generating pressure steps with rise times below 1 μs are highly suitable as standards for dynamic pressures in gas. In this work, we present the results from applying a fast-opening valve (FOV) to a shock tube designed for dynamic pressure measurements. We compare the performance of the shock tube when operated with conventional single and double diaphragms and when operated using an FOV. Different aspects are addressed: shock-wave formation, repeatability in amplitude of the realized pressure steps, the assessment of the required driver pressure for realizing nominal pressure steps, and economy. The results show that using the FOV has many advantages compared to the diaphragm: better repeatability, eight times faster to operate, and enables automation of the test sequences. MDPI 2021-06-29 /pmc/articles/PMC8271782/ /pubmed/34210071 http://dx.doi.org/10.3390/s21134470 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Amer, Eynas
Wozniak, Mikolaj
Jönsson, Gustav
Arrhén, Fredrik
Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration
title Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration
title_full Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration
title_fullStr Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration
title_full_unstemmed Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration
title_short Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration
title_sort evaluation of shock tube retrofitted with fast-opening valve for dynamic pressure calibration
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8271782/
https://www.ncbi.nlm.nih.gov/pubmed/34210071
http://dx.doi.org/10.3390/s21134470
work_keys_str_mv AT amereynas evaluationofshocktuberetrofittedwithfastopeningvalvefordynamicpressurecalibration
AT wozniakmikolaj evaluationofshocktuberetrofittedwithfastopeningvalvefordynamicpressurecalibration
AT jonssongustav evaluationofshocktuberetrofittedwithfastopeningvalvefordynamicpressurecalibration
AT arrhenfredrik evaluationofshocktuberetrofittedwithfastopeningvalvefordynamicpressurecalibration