Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration
Accurate dynamic pressure measurements are increasingly important. While traceability is lacking, several National Metrology Institutes (NMIs) and calibration laboratories are currently establishing calibration capacities. Shock tubes generating pressure steps with rise times below 1 μs are highly s...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8271782/ https://www.ncbi.nlm.nih.gov/pubmed/34210071 http://dx.doi.org/10.3390/s21134470 |
_version_ | 1783721073057988608 |
---|---|
author | Amer, Eynas Wozniak, Mikolaj Jönsson, Gustav Arrhén, Fredrik |
author_facet | Amer, Eynas Wozniak, Mikolaj Jönsson, Gustav Arrhén, Fredrik |
author_sort | Amer, Eynas |
collection | PubMed |
description | Accurate dynamic pressure measurements are increasingly important. While traceability is lacking, several National Metrology Institutes (NMIs) and calibration laboratories are currently establishing calibration capacities. Shock tubes generating pressure steps with rise times below 1 μs are highly suitable as standards for dynamic pressures in gas. In this work, we present the results from applying a fast-opening valve (FOV) to a shock tube designed for dynamic pressure measurements. We compare the performance of the shock tube when operated with conventional single and double diaphragms and when operated using an FOV. Different aspects are addressed: shock-wave formation, repeatability in amplitude of the realized pressure steps, the assessment of the required driver pressure for realizing nominal pressure steps, and economy. The results show that using the FOV has many advantages compared to the diaphragm: better repeatability, eight times faster to operate, and enables automation of the test sequences. |
format | Online Article Text |
id | pubmed-8271782 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-82717822021-07-11 Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration Amer, Eynas Wozniak, Mikolaj Jönsson, Gustav Arrhén, Fredrik Sensors (Basel) Communication Accurate dynamic pressure measurements are increasingly important. While traceability is lacking, several National Metrology Institutes (NMIs) and calibration laboratories are currently establishing calibration capacities. Shock tubes generating pressure steps with rise times below 1 μs are highly suitable as standards for dynamic pressures in gas. In this work, we present the results from applying a fast-opening valve (FOV) to a shock tube designed for dynamic pressure measurements. We compare the performance of the shock tube when operated with conventional single and double diaphragms and when operated using an FOV. Different aspects are addressed: shock-wave formation, repeatability in amplitude of the realized pressure steps, the assessment of the required driver pressure for realizing nominal pressure steps, and economy. The results show that using the FOV has many advantages compared to the diaphragm: better repeatability, eight times faster to operate, and enables automation of the test sequences. MDPI 2021-06-29 /pmc/articles/PMC8271782/ /pubmed/34210071 http://dx.doi.org/10.3390/s21134470 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Amer, Eynas Wozniak, Mikolaj Jönsson, Gustav Arrhén, Fredrik Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration |
title | Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration |
title_full | Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration |
title_fullStr | Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration |
title_full_unstemmed | Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration |
title_short | Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration |
title_sort | evaluation of shock tube retrofitted with fast-opening valve for dynamic pressure calibration |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8271782/ https://www.ncbi.nlm.nih.gov/pubmed/34210071 http://dx.doi.org/10.3390/s21134470 |
work_keys_str_mv | AT amereynas evaluationofshocktuberetrofittedwithfastopeningvalvefordynamicpressurecalibration AT wozniakmikolaj evaluationofshocktuberetrofittedwithfastopeningvalvefordynamicpressurecalibration AT jonssongustav evaluationofshocktuberetrofittedwithfastopeningvalvefordynamicpressurecalibration AT arrhenfredrik evaluationofshocktuberetrofittedwithfastopeningvalvefordynamicpressurecalibration |