Cargando…
Relationship between the difference in electric pulp test values and the diagnostic type of pulpitis
BACKGROUND: According to the diagnosis criteria of the American Association of Endodontists (AAE), sensitive responses to cold and/or heat tests of suspected teeth compared with those of control teeth can be used for the diagnosis of pulpitis, but the role of electric pulp test (EPT) is not mentione...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8272274/ https://www.ncbi.nlm.nih.gov/pubmed/34246278 http://dx.doi.org/10.1186/s12903-021-01696-9 |
_version_ | 1783721185890009088 |
---|---|
author | Sui, Huachao Lv, Yangyang Xiao, Mo Zhou, Liwen Qiao, Feng Zheng, Jinxin Sun, Cuicui Fu, Jieni Chen, Yufan Liu, Yimeng Zhou, Jie Wu, Ligeng |
author_facet | Sui, Huachao Lv, Yangyang Xiao, Mo Zhou, Liwen Qiao, Feng Zheng, Jinxin Sun, Cuicui Fu, Jieni Chen, Yufan Liu, Yimeng Zhou, Jie Wu, Ligeng |
author_sort | Sui, Huachao |
collection | PubMed |
description | BACKGROUND: According to the diagnosis criteria of the American Association of Endodontists (AAE), sensitive responses to cold and/or heat tests of suspected teeth compared with those of control teeth can be used for the diagnosis of pulpitis, but the role of electric pulp test (EPT) is not mentioned. It is believed that EPT has some limitations in determining the vitality of the pulp. The aim of this study was to explore the association between the difference in EPT values and the differential diagnoses of reversible pulpitis (RP) and symptomatic irreversible pulpitis (SIRP) caused by dental caries. METHODS: A total of 203 cases with pulpitis caused by dental caries were included. A diagnosis of pulpitis was made on the basis of the diagnostic criteria of AAE. Patient demographic and clinical examination data were collected. The EPT values of the suspected teeth and control teeth were measured, and the differences between them were calculated. The correlation between the difference in the EPT values and diagnosis of pulpitis was analyzed using univariate and multivariate logistic regression. RESULTS: In the 203 cases (78 males and 125 females; 115 cases of RP, 88 cases of SIRP; 9 anterior teeth, 59 premolars, and 135 molars), the mean patient age was 34.04 ± 13.02 (standard deviation) years. The unadjusted (crude) model, model 1 (adjusted for age), model 2 (adjusted for age and sex), and model 3 (adjusted for age, sex, and tooth type) were established for the statistical analyses. In model 3 [odds ratio (OR) = 1.025; 95% confidence interval (CI) 1.002–1.050; P = 0.035], the difference in EPT values between RP and SIRP was statistically significant. However, the areas under the curve of predictive probability of the crude model, model 1, model 2, and model 3 were 0.565, 0.570, 0.585, and 0.617, respectively, showing that the model accuracy was low. The P-value for the trend in differences between the EPT values as a categorical variable showed that the differences in the EPT values, comparing RP and SIRP, were not statistically significant. CONCLUSIONS: Based on the present data, the difference in EPT values was not sufficient to differentiate RP from SIRP. |
format | Online Article Text |
id | pubmed-8272274 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-82722742021-07-12 Relationship between the difference in electric pulp test values and the diagnostic type of pulpitis Sui, Huachao Lv, Yangyang Xiao, Mo Zhou, Liwen Qiao, Feng Zheng, Jinxin Sun, Cuicui Fu, Jieni Chen, Yufan Liu, Yimeng Zhou, Jie Wu, Ligeng BMC Oral Health Research BACKGROUND: According to the diagnosis criteria of the American Association of Endodontists (AAE), sensitive responses to cold and/or heat tests of suspected teeth compared with those of control teeth can be used for the diagnosis of pulpitis, but the role of electric pulp test (EPT) is not mentioned. It is believed that EPT has some limitations in determining the vitality of the pulp. The aim of this study was to explore the association between the difference in EPT values and the differential diagnoses of reversible pulpitis (RP) and symptomatic irreversible pulpitis (SIRP) caused by dental caries. METHODS: A total of 203 cases with pulpitis caused by dental caries were included. A diagnosis of pulpitis was made on the basis of the diagnostic criteria of AAE. Patient demographic and clinical examination data were collected. The EPT values of the suspected teeth and control teeth were measured, and the differences between them were calculated. The correlation between the difference in the EPT values and diagnosis of pulpitis was analyzed using univariate and multivariate logistic regression. RESULTS: In the 203 cases (78 males and 125 females; 115 cases of RP, 88 cases of SIRP; 9 anterior teeth, 59 premolars, and 135 molars), the mean patient age was 34.04 ± 13.02 (standard deviation) years. The unadjusted (crude) model, model 1 (adjusted for age), model 2 (adjusted for age and sex), and model 3 (adjusted for age, sex, and tooth type) were established for the statistical analyses. In model 3 [odds ratio (OR) = 1.025; 95% confidence interval (CI) 1.002–1.050; P = 0.035], the difference in EPT values between RP and SIRP was statistically significant. However, the areas under the curve of predictive probability of the crude model, model 1, model 2, and model 3 were 0.565, 0.570, 0.585, and 0.617, respectively, showing that the model accuracy was low. The P-value for the trend in differences between the EPT values as a categorical variable showed that the differences in the EPT values, comparing RP and SIRP, were not statistically significant. CONCLUSIONS: Based on the present data, the difference in EPT values was not sufficient to differentiate RP from SIRP. BioMed Central 2021-07-10 /pmc/articles/PMC8272274/ /pubmed/34246278 http://dx.doi.org/10.1186/s12903-021-01696-9 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Sui, Huachao Lv, Yangyang Xiao, Mo Zhou, Liwen Qiao, Feng Zheng, Jinxin Sun, Cuicui Fu, Jieni Chen, Yufan Liu, Yimeng Zhou, Jie Wu, Ligeng Relationship between the difference in electric pulp test values and the diagnostic type of pulpitis |
title | Relationship between the difference in electric pulp test values and the diagnostic type of pulpitis |
title_full | Relationship between the difference in electric pulp test values and the diagnostic type of pulpitis |
title_fullStr | Relationship between the difference in electric pulp test values and the diagnostic type of pulpitis |
title_full_unstemmed | Relationship between the difference in electric pulp test values and the diagnostic type of pulpitis |
title_short | Relationship between the difference in electric pulp test values and the diagnostic type of pulpitis |
title_sort | relationship between the difference in electric pulp test values and the diagnostic type of pulpitis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8272274/ https://www.ncbi.nlm.nih.gov/pubmed/34246278 http://dx.doi.org/10.1186/s12903-021-01696-9 |
work_keys_str_mv | AT suihuachao relationshipbetweenthedifferenceinelectricpulptestvaluesandthediagnostictypeofpulpitis AT lvyangyang relationshipbetweenthedifferenceinelectricpulptestvaluesandthediagnostictypeofpulpitis AT xiaomo relationshipbetweenthedifferenceinelectricpulptestvaluesandthediagnostictypeofpulpitis AT zhouliwen relationshipbetweenthedifferenceinelectricpulptestvaluesandthediagnostictypeofpulpitis AT qiaofeng relationshipbetweenthedifferenceinelectricpulptestvaluesandthediagnostictypeofpulpitis AT zhengjinxin relationshipbetweenthedifferenceinelectricpulptestvaluesandthediagnostictypeofpulpitis AT suncuicui relationshipbetweenthedifferenceinelectricpulptestvaluesandthediagnostictypeofpulpitis AT fujieni relationshipbetweenthedifferenceinelectricpulptestvaluesandthediagnostictypeofpulpitis AT chenyufan relationshipbetweenthedifferenceinelectricpulptestvaluesandthediagnostictypeofpulpitis AT liuyimeng relationshipbetweenthedifferenceinelectricpulptestvaluesandthediagnostictypeofpulpitis AT zhoujie relationshipbetweenthedifferenceinelectricpulptestvaluesandthediagnostictypeofpulpitis AT wuligeng relationshipbetweenthedifferenceinelectricpulptestvaluesandthediagnostictypeofpulpitis |