Cargando…
Contamination of single fluid-filled intragastric balloons with orogastric fluid is not associated with hyperinflation: an ex-vivo study and systematic review of literature
BACKGROUND: Spontaneous hyperinflation is reported to the Food and Drug Administration as a complication of intragastric balloons. It is postulated that orogastric contamination of the intragastric balloon may cause this phenomenon. We sought to investigate the effects of intentional balloon contami...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8273974/ https://www.ncbi.nlm.nih.gov/pubmed/34247581 http://dx.doi.org/10.1186/s12876-021-01863-w |
_version_ | 1783721477406720000 |
---|---|
author | Hawa, Fadi Vargas, Eric J. Acosta, Andres McRae, Alison Bazerbachi, Fateh Abu Dayyeh, Barham K. |
author_facet | Hawa, Fadi Vargas, Eric J. Acosta, Andres McRae, Alison Bazerbachi, Fateh Abu Dayyeh, Barham K. |
author_sort | Hawa, Fadi |
collection | PubMed |
description | BACKGROUND: Spontaneous hyperinflation is reported to the Food and Drug Administration as a complication of intragastric balloons. It is postulated that orogastric contamination of the intragastric balloon may cause this phenomenon. We sought to investigate the effects of intentional balloon contamination with gastric contents on intragastric balloon perimeter and contents, whether methylene blue plays a role in preventing spontaneous hyperinflation, and review the available literature on spontaneous hyperinflation. METHODS: Four pairs of balloons with different combinations of sterile saline, orogastric contaminants, and methylene blue were incubated in a 37 °C water bath for six months to simulate physiological conditions with serial measurements of balloon perimeter. Our findings were compared against a systematic review across multiple databases to summarize the available literature. RESULTS: Balloon mean perimeter decreased from 33.5 cm ± 0.53 cm to 28.5 cm ± 0.46 cm (p < 0.0001). No significant differences were seen with the methylene blue group. Only 11 cases were found reported in the literature. CONCLUSIONS: Despite contaminating intragastric balloons with gastric aspirates, hyperinflation did not occur, and other factors may be in play to account for this phenomenon, when observed. Rates of hyperinflation remain under-reported in the literature. Further controlled experiments are needed. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12876-021-01863-w. |
format | Online Article Text |
id | pubmed-8273974 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-82739742021-07-13 Contamination of single fluid-filled intragastric balloons with orogastric fluid is not associated with hyperinflation: an ex-vivo study and systematic review of literature Hawa, Fadi Vargas, Eric J. Acosta, Andres McRae, Alison Bazerbachi, Fateh Abu Dayyeh, Barham K. BMC Gastroenterol Research BACKGROUND: Spontaneous hyperinflation is reported to the Food and Drug Administration as a complication of intragastric balloons. It is postulated that orogastric contamination of the intragastric balloon may cause this phenomenon. We sought to investigate the effects of intentional balloon contamination with gastric contents on intragastric balloon perimeter and contents, whether methylene blue plays a role in preventing spontaneous hyperinflation, and review the available literature on spontaneous hyperinflation. METHODS: Four pairs of balloons with different combinations of sterile saline, orogastric contaminants, and methylene blue were incubated in a 37 °C water bath for six months to simulate physiological conditions with serial measurements of balloon perimeter. Our findings were compared against a systematic review across multiple databases to summarize the available literature. RESULTS: Balloon mean perimeter decreased from 33.5 cm ± 0.53 cm to 28.5 cm ± 0.46 cm (p < 0.0001). No significant differences were seen with the methylene blue group. Only 11 cases were found reported in the literature. CONCLUSIONS: Despite contaminating intragastric balloons with gastric aspirates, hyperinflation did not occur, and other factors may be in play to account for this phenomenon, when observed. Rates of hyperinflation remain under-reported in the literature. Further controlled experiments are needed. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12876-021-01863-w. BioMed Central 2021-07-12 /pmc/articles/PMC8273974/ /pubmed/34247581 http://dx.doi.org/10.1186/s12876-021-01863-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Hawa, Fadi Vargas, Eric J. Acosta, Andres McRae, Alison Bazerbachi, Fateh Abu Dayyeh, Barham K. Contamination of single fluid-filled intragastric balloons with orogastric fluid is not associated with hyperinflation: an ex-vivo study and systematic review of literature |
title | Contamination of single fluid-filled intragastric balloons with orogastric fluid is not associated with hyperinflation: an ex-vivo study and systematic review of literature |
title_full | Contamination of single fluid-filled intragastric balloons with orogastric fluid is not associated with hyperinflation: an ex-vivo study and systematic review of literature |
title_fullStr | Contamination of single fluid-filled intragastric balloons with orogastric fluid is not associated with hyperinflation: an ex-vivo study and systematic review of literature |
title_full_unstemmed | Contamination of single fluid-filled intragastric balloons with orogastric fluid is not associated with hyperinflation: an ex-vivo study and systematic review of literature |
title_short | Contamination of single fluid-filled intragastric balloons with orogastric fluid is not associated with hyperinflation: an ex-vivo study and systematic review of literature |
title_sort | contamination of single fluid-filled intragastric balloons with orogastric fluid is not associated with hyperinflation: an ex-vivo study and systematic review of literature |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8273974/ https://www.ncbi.nlm.nih.gov/pubmed/34247581 http://dx.doi.org/10.1186/s12876-021-01863-w |
work_keys_str_mv | AT hawafadi contaminationofsinglefluidfilledintragastricballoonswithorogastricfluidisnotassociatedwithhyperinflationanexvivostudyandsystematicreviewofliterature AT vargasericj contaminationofsinglefluidfilledintragastricballoonswithorogastricfluidisnotassociatedwithhyperinflationanexvivostudyandsystematicreviewofliterature AT acostaandres contaminationofsinglefluidfilledintragastricballoonswithorogastricfluidisnotassociatedwithhyperinflationanexvivostudyandsystematicreviewofliterature AT mcraealison contaminationofsinglefluidfilledintragastricballoonswithorogastricfluidisnotassociatedwithhyperinflationanexvivostudyandsystematicreviewofliterature AT bazerbachifateh contaminationofsinglefluidfilledintragastricballoonswithorogastricfluidisnotassociatedwithhyperinflationanexvivostudyandsystematicreviewofliterature AT abudayyehbarhamk contaminationofsinglefluidfilledintragastricballoonswithorogastricfluidisnotassociatedwithhyperinflationanexvivostudyandsystematicreviewofliterature |