Cargando…
Investigation of (18)F and (89)Zr Isotopes Self-Absorption and Dose Rate Parameters for PET Imaging
This work concerns study of self-absorption factor (SAF) and dose rate constants of zirconium-89 ((89)Zr) for the purpose of radiation protection in positron emission tomography (PET) and to compare them with those of (18)F-deoxyglucose ((18)F-FDG). We analyzed the emitted energy spectra by (18)F an...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8274111/ https://www.ncbi.nlm.nih.gov/pubmed/34290574 http://dx.doi.org/10.1177/15593258211028467 |
_version_ | 1783721501396041728 |
---|---|
author | Alfuraih, Abdulrahman A. Alzimami, Khalid Ma, Andy K. |
author_facet | Alfuraih, Abdulrahman A. Alzimami, Khalid Ma, Andy K. |
author_sort | Alfuraih, Abdulrahman A. |
collection | PubMed |
description | This work concerns study of self-absorption factor (SAF) and dose rate constants of zirconium-89 ((89)Zr) for the purpose of radiation protection in positron emission tomography (PET) and to compare them with those of (18)F-deoxyglucose ((18)F-FDG). We analyzed the emitted energy spectra by (18)F and (89)Zr through anthropomorphic phantom and calculated the absorbed energy using Monte Carlo method. The dose rate constants for both radionuclides were estimated with 2 different fluence-to-effective dose conversion coefficients. Our estimated SAF value of 0.65 for (18)F agreed with the recommendation of the American Association of Physicists in Medicine (AAPM). The SAF for (89)Zr was in the range of 0.61-0.66 depending on the biodistribution. Using the fluence-to-effective dose conversion coefficients recommended jointly by the American National Standards Institute and the American Nuclear Society (ANSI/ANS), the dose rate at 1 m from the patient for (18)F was 0.143 μSv·MBq(−1)·hr(−1), which is consistent with the AAPM recommendation, while that for (89)Zr was 0.154 μSv·MBq(−1)·hr(−1). With the conversion coefficients currently recommended by the International Committee on Radiological Protection (ICRP), the dose rate estimates were lowered by 2.8% and 2.6% for (89)Zr and (18)F, respectively. Also, we observed that the AAPM derived dose is an overestimation near the patient, compared to our simulations, which can be explained by the biodistribution nature and the assumption of the point source. Thus, we proposed new radiation protection factors for (89)Zr radionuclide. |
format | Online Article Text |
id | pubmed-8274111 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-82741112021-07-20 Investigation of (18)F and (89)Zr Isotopes Self-Absorption and Dose Rate Parameters for PET Imaging Alfuraih, Abdulrahman A. Alzimami, Khalid Ma, Andy K. Dose Response Original Article This work concerns study of self-absorption factor (SAF) and dose rate constants of zirconium-89 ((89)Zr) for the purpose of radiation protection in positron emission tomography (PET) and to compare them with those of (18)F-deoxyglucose ((18)F-FDG). We analyzed the emitted energy spectra by (18)F and (89)Zr through anthropomorphic phantom and calculated the absorbed energy using Monte Carlo method. The dose rate constants for both radionuclides were estimated with 2 different fluence-to-effective dose conversion coefficients. Our estimated SAF value of 0.65 for (18)F agreed with the recommendation of the American Association of Physicists in Medicine (AAPM). The SAF for (89)Zr was in the range of 0.61-0.66 depending on the biodistribution. Using the fluence-to-effective dose conversion coefficients recommended jointly by the American National Standards Institute and the American Nuclear Society (ANSI/ANS), the dose rate at 1 m from the patient for (18)F was 0.143 μSv·MBq(−1)·hr(−1), which is consistent with the AAPM recommendation, while that for (89)Zr was 0.154 μSv·MBq(−1)·hr(−1). With the conversion coefficients currently recommended by the International Committee on Radiological Protection (ICRP), the dose rate estimates were lowered by 2.8% and 2.6% for (89)Zr and (18)F, respectively. Also, we observed that the AAPM derived dose is an overestimation near the patient, compared to our simulations, which can be explained by the biodistribution nature and the assumption of the point source. Thus, we proposed new radiation protection factors for (89)Zr radionuclide. SAGE Publications 2021-07-09 /pmc/articles/PMC8274111/ /pubmed/34290574 http://dx.doi.org/10.1177/15593258211028467 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Alfuraih, Abdulrahman A. Alzimami, Khalid Ma, Andy K. Investigation of (18)F and (89)Zr Isotopes Self-Absorption and Dose Rate Parameters for PET Imaging |
title | Investigation of (18)F and (89)Zr Isotopes Self-Absorption and Dose Rate Parameters for PET Imaging |
title_full | Investigation of (18)F and (89)Zr Isotopes Self-Absorption and Dose Rate Parameters for PET Imaging |
title_fullStr | Investigation of (18)F and (89)Zr Isotopes Self-Absorption and Dose Rate Parameters for PET Imaging |
title_full_unstemmed | Investigation of (18)F and (89)Zr Isotopes Self-Absorption and Dose Rate Parameters for PET Imaging |
title_short | Investigation of (18)F and (89)Zr Isotopes Self-Absorption and Dose Rate Parameters for PET Imaging |
title_sort | investigation of (18)f and (89)zr isotopes self-absorption and dose rate parameters for pet imaging |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8274111/ https://www.ncbi.nlm.nih.gov/pubmed/34290574 http://dx.doi.org/10.1177/15593258211028467 |
work_keys_str_mv | AT alfuraihabdulrahmana investigationof18fand89zrisotopesselfabsorptionanddoserateparametersforpetimaging AT alzimamikhalid investigationof18fand89zrisotopesselfabsorptionanddoserateparametersforpetimaging AT maandyk investigationof18fand89zrisotopesselfabsorptionanddoserateparametersforpetimaging |