Cargando…

Arthroscopy‐Assisted Treatment of Wear Debris Pseudotumor After Total Knee Arthroplasty: A Case Report

BACKGROUND: Wear debris pseudotumors are a rare complication after total knee arthroplasty (TKA) and have seldom been reported in the recent literature. There is no consensus on the best therapeutic method, but the high quality curative treatment, safe, low invasive treatments are required for the p...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Hantao, Shen, Liping, Lei, Xinhuan, Chen, Linglin, Zhu, Rangteng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons Australia, Ltd 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8274178/
https://www.ncbi.nlm.nih.gov/pubmed/33955669
http://dx.doi.org/10.1111/os.12904
_version_ 1783721512380923904
author Jiang, Hantao
Shen, Liping
Lei, Xinhuan
Chen, Linglin
Zhu, Rangteng
author_facet Jiang, Hantao
Shen, Liping
Lei, Xinhuan
Chen, Linglin
Zhu, Rangteng
author_sort Jiang, Hantao
collection PubMed
description BACKGROUND: Wear debris pseudotumors are a rare complication after total knee arthroplasty (TKA) and have seldom been reported in the recent literature. There is no consensus on the best therapeutic method, but the high quality curative treatment, safe, low invasive treatments are required for the patients. CASE PRESENTATION: In this paper, we present the case of a 74‐year‐old man with a wear debris pseudotumor after TKA with symptoms of severe pain and functional disability of his right knee. X‐ray examination showed that the medial compartment of the right knee was narrowing. Magnetic resonance imaging (MRI) and Doppler ultrasound both revealed a polycystic mass at the posteromedial side of the patient's right knee. Considering the bad health condition and the minimally invasive surgery requirement of this senior patient, arthroscopic knee debridement and percutaneous cystic mass suction were carried out simultaneously. Video arthroscopy of the right knee showed visible inflammatory soft tissue, obvious polyethylene fragments, wear of the polyethylene prothesis, and a broken polyethylene insert. The intraarticular polyethylene wear debris was removed as much as possible, and inflammatory soft tissue was debrided and sent for pathology. Postoperative pathology showed polyethylene debris in the soft tissue with an apparent multinucleated giant cell response, which was consistent with foreign body granuloma. All clinical manifestation was improved and Lysholm scores were significantly better at one year with this treatment, increasing from 32 points to 71 points. CONCLUSION: After two years of follow‐up, the patient's knee joint was significantly relieved from soreness and pain, and walking was not significantly restricted. Our treatment could not address the root cause of the wear debris pseudotumor, which was due to prosthesis failure, but sometimes, such an approach is the safest, most economical, and most effective choice for patients who are intolerant to reoperation.
format Online
Article
Text
id pubmed-8274178
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley & Sons Australia, Ltd
record_format MEDLINE/PubMed
spelling pubmed-82741782021-07-14 Arthroscopy‐Assisted Treatment of Wear Debris Pseudotumor After Total Knee Arthroplasty: A Case Report Jiang, Hantao Shen, Liping Lei, Xinhuan Chen, Linglin Zhu, Rangteng Orthop Surg Case Reports BACKGROUND: Wear debris pseudotumors are a rare complication after total knee arthroplasty (TKA) and have seldom been reported in the recent literature. There is no consensus on the best therapeutic method, but the high quality curative treatment, safe, low invasive treatments are required for the patients. CASE PRESENTATION: In this paper, we present the case of a 74‐year‐old man with a wear debris pseudotumor after TKA with symptoms of severe pain and functional disability of his right knee. X‐ray examination showed that the medial compartment of the right knee was narrowing. Magnetic resonance imaging (MRI) and Doppler ultrasound both revealed a polycystic mass at the posteromedial side of the patient's right knee. Considering the bad health condition and the minimally invasive surgery requirement of this senior patient, arthroscopic knee debridement and percutaneous cystic mass suction were carried out simultaneously. Video arthroscopy of the right knee showed visible inflammatory soft tissue, obvious polyethylene fragments, wear of the polyethylene prothesis, and a broken polyethylene insert. The intraarticular polyethylene wear debris was removed as much as possible, and inflammatory soft tissue was debrided and sent for pathology. Postoperative pathology showed polyethylene debris in the soft tissue with an apparent multinucleated giant cell response, which was consistent with foreign body granuloma. All clinical manifestation was improved and Lysholm scores were significantly better at one year with this treatment, increasing from 32 points to 71 points. CONCLUSION: After two years of follow‐up, the patient's knee joint was significantly relieved from soreness and pain, and walking was not significantly restricted. Our treatment could not address the root cause of the wear debris pseudotumor, which was due to prosthesis failure, but sometimes, such an approach is the safest, most economical, and most effective choice for patients who are intolerant to reoperation. John Wiley & Sons Australia, Ltd 2021-05-06 /pmc/articles/PMC8274178/ /pubmed/33955669 http://dx.doi.org/10.1111/os.12904 Text en © 2021 The Authors. Orthopaedic Surgery published by Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Case Reports
Jiang, Hantao
Shen, Liping
Lei, Xinhuan
Chen, Linglin
Zhu, Rangteng
Arthroscopy‐Assisted Treatment of Wear Debris Pseudotumor After Total Knee Arthroplasty: A Case Report
title Arthroscopy‐Assisted Treatment of Wear Debris Pseudotumor After Total Knee Arthroplasty: A Case Report
title_full Arthroscopy‐Assisted Treatment of Wear Debris Pseudotumor After Total Knee Arthroplasty: A Case Report
title_fullStr Arthroscopy‐Assisted Treatment of Wear Debris Pseudotumor After Total Knee Arthroplasty: A Case Report
title_full_unstemmed Arthroscopy‐Assisted Treatment of Wear Debris Pseudotumor After Total Knee Arthroplasty: A Case Report
title_short Arthroscopy‐Assisted Treatment of Wear Debris Pseudotumor After Total Knee Arthroplasty: A Case Report
title_sort arthroscopy‐assisted treatment of wear debris pseudotumor after total knee arthroplasty: a case report
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8274178/
https://www.ncbi.nlm.nih.gov/pubmed/33955669
http://dx.doi.org/10.1111/os.12904
work_keys_str_mv AT jianghantao arthroscopyassistedtreatmentofweardebrispseudotumoraftertotalkneearthroplastyacasereport
AT shenliping arthroscopyassistedtreatmentofweardebrispseudotumoraftertotalkneearthroplastyacasereport
AT leixinhuan arthroscopyassistedtreatmentofweardebrispseudotumoraftertotalkneearthroplastyacasereport
AT chenlinglin arthroscopyassistedtreatmentofweardebrispseudotumoraftertotalkneearthroplastyacasereport
AT zhurangteng arthroscopyassistedtreatmentofweardebrispseudotumoraftertotalkneearthroplastyacasereport