Cargando…

Detection of occult atrial fibrillation with 24-hour ECG after cryptogenic acute stroke or transient ischaemic attack: A retrospective cross-sectional study in a primary care database in Israel

BACKGROUND: Ischaemic stroke or cerebrovascular accident (CVA) due to occult atrial fibrillation (AF) may cause severe morbidity and mortality. Diagnosing occult AF can be challenging and there is no consensus regarding the optimal duration of screening. A 24-hour Holter electrocardiogram (ECG) is f...

Descripción completa

Detalles Bibliográficos
Autores principales: Liran, Ori, Banon, Tamar, Grossman, Alon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8274499/
https://www.ncbi.nlm.nih.gov/pubmed/34240675
http://dx.doi.org/10.1080/13814788.2021.1947237
_version_ 1783721561795067904
author Liran, Ori
Banon, Tamar
Grossman, Alon
author_facet Liran, Ori
Banon, Tamar
Grossman, Alon
author_sort Liran, Ori
collection PubMed
description BACKGROUND: Ischaemic stroke or cerebrovascular accident (CVA) due to occult atrial fibrillation (AF) may cause severe morbidity and mortality. Diagnosing occult AF can be challenging and there is no consensus regarding the optimal duration of screening. A 24-hour Holter electrocardiogram (ECG) is frequently employed to detect occult AF following ischaemic CVA. OBJECTIVES: Demonstration of occult AF detection rate using a 24-hour Holter ECG in a primary care setting with descriptive analyses of independent variables to compare AF detected and non-detected patients. METHODS: This retrospective cross-sectional study utilised primary care data and included patients 50 years and older with a new CVA or transient ischaemic attack (TIA) diagnosis followed by a 24-hour Holter examination within 6 months, between 01 January 2013 and 01 June 2019. The analyses included descriptive statistics comparing demographics and clinical characteristics in patients who had AF or Atrial Flutter (AFL) detection to those who did not. RESULTS: Out of 5015 eligible patients, 66 (1.3%) were diagnosed with AF/AFL, with a number needed to screen of 88.5. Compared with those without AF/AFL detection, those diagnosed were older (75.42 ± 7.89 vs. 69.89 ± 9.88, p = 0.050), had a higher prevalence of hypertension (80.3% vs. 66.8%, p = 0.021) and chronic kidney disease (CKD) (71.2% vs. 44.2%, p < 0.001). CONCLUSION: 24-hour Holter has a low AF/AFL detection rate. Older persons and those with hypertension or CKD are more likely to be detected with AF/AFL using this method.
format Online
Article
Text
id pubmed-8274499
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-82744992021-07-20 Detection of occult atrial fibrillation with 24-hour ECG after cryptogenic acute stroke or transient ischaemic attack: A retrospective cross-sectional study in a primary care database in Israel Liran, Ori Banon, Tamar Grossman, Alon Eur J Gen Pract Original Articles BACKGROUND: Ischaemic stroke or cerebrovascular accident (CVA) due to occult atrial fibrillation (AF) may cause severe morbidity and mortality. Diagnosing occult AF can be challenging and there is no consensus regarding the optimal duration of screening. A 24-hour Holter electrocardiogram (ECG) is frequently employed to detect occult AF following ischaemic CVA. OBJECTIVES: Demonstration of occult AF detection rate using a 24-hour Holter ECG in a primary care setting with descriptive analyses of independent variables to compare AF detected and non-detected patients. METHODS: This retrospective cross-sectional study utilised primary care data and included patients 50 years and older with a new CVA or transient ischaemic attack (TIA) diagnosis followed by a 24-hour Holter examination within 6 months, between 01 January 2013 and 01 June 2019. The analyses included descriptive statistics comparing demographics and clinical characteristics in patients who had AF or Atrial Flutter (AFL) detection to those who did not. RESULTS: Out of 5015 eligible patients, 66 (1.3%) were diagnosed with AF/AFL, with a number needed to screen of 88.5. Compared with those without AF/AFL detection, those diagnosed were older (75.42 ± 7.89 vs. 69.89 ± 9.88, p = 0.050), had a higher prevalence of hypertension (80.3% vs. 66.8%, p = 0.021) and chronic kidney disease (CKD) (71.2% vs. 44.2%, p < 0.001). CONCLUSION: 24-hour Holter has a low AF/AFL detection rate. Older persons and those with hypertension or CKD are more likely to be detected with AF/AFL using this method. Taylor & Francis 2021-07-09 /pmc/articles/PMC8274499/ /pubmed/34240675 http://dx.doi.org/10.1080/13814788.2021.1947237 Text en © 2021 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Liran, Ori
Banon, Tamar
Grossman, Alon
Detection of occult atrial fibrillation with 24-hour ECG after cryptogenic acute stroke or transient ischaemic attack: A retrospective cross-sectional study in a primary care database in Israel
title Detection of occult atrial fibrillation with 24-hour ECG after cryptogenic acute stroke or transient ischaemic attack: A retrospective cross-sectional study in a primary care database in Israel
title_full Detection of occult atrial fibrillation with 24-hour ECG after cryptogenic acute stroke or transient ischaemic attack: A retrospective cross-sectional study in a primary care database in Israel
title_fullStr Detection of occult atrial fibrillation with 24-hour ECG after cryptogenic acute stroke or transient ischaemic attack: A retrospective cross-sectional study in a primary care database in Israel
title_full_unstemmed Detection of occult atrial fibrillation with 24-hour ECG after cryptogenic acute stroke or transient ischaemic attack: A retrospective cross-sectional study in a primary care database in Israel
title_short Detection of occult atrial fibrillation with 24-hour ECG after cryptogenic acute stroke or transient ischaemic attack: A retrospective cross-sectional study in a primary care database in Israel
title_sort detection of occult atrial fibrillation with 24-hour ecg after cryptogenic acute stroke or transient ischaemic attack: a retrospective cross-sectional study in a primary care database in israel
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8274499/
https://www.ncbi.nlm.nih.gov/pubmed/34240675
http://dx.doi.org/10.1080/13814788.2021.1947237
work_keys_str_mv AT liranori detectionofoccultatrialfibrillationwith24hourecgaftercryptogenicacutestrokeortransientischaemicattackaretrospectivecrosssectionalstudyinaprimarycaredatabaseinisrael
AT banontamar detectionofoccultatrialfibrillationwith24hourecgaftercryptogenicacutestrokeortransientischaemicattackaretrospectivecrosssectionalstudyinaprimarycaredatabaseinisrael
AT grossmanalon detectionofoccultatrialfibrillationwith24hourecgaftercryptogenicacutestrokeortransientischaemicattackaretrospectivecrosssectionalstudyinaprimarycaredatabaseinisrael