Cargando…

An Evaluation of the Agreement Between a Computerized Stereoscopic Game Test and the TNO Stereoacuity Test

PURPOSE: Stereo-anomaly is commonly associated with amblyopia. An investigation was conducted to determine whether the measurements of stereoacuity obtained with the stereoacuity reference test (TNO Test) show an agreement with a computer stereoscope video game. METHODS: Thirty-two subjects (mean ag...

Descripción completa

Detalles Bibliográficos
Autores principales: Portela-Camino, Juan Antonio, Martín-González, Santiago, Ruiz-Alcocer, Javier, Illarramendi-Mendicute, Igor, Garrido-Mercado, Rafaela
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8275165/
https://www.ncbi.nlm.nih.gov/pubmed/34267572
http://dx.doi.org/10.2147/OPTO.S308445
_version_ 1783721676873138176
author Portela-Camino, Juan Antonio
Martín-González, Santiago
Ruiz-Alcocer, Javier
Illarramendi-Mendicute, Igor
Garrido-Mercado, Rafaela
author_facet Portela-Camino, Juan Antonio
Martín-González, Santiago
Ruiz-Alcocer, Javier
Illarramendi-Mendicute, Igor
Garrido-Mercado, Rafaela
author_sort Portela-Camino, Juan Antonio
collection PubMed
description PURPOSE: Stereo-anomaly is commonly associated with amblyopia. An investigation was conducted to determine whether the measurements of stereoacuity obtained with the stereoacuity reference test (TNO Test) show an agreement with a computer stereoscope video game. METHODS: Thirty-two subjects (mean age 9.37±2.00 years) with an amblyopia history were selected for a blind and randomized study of stereoacuity improvement through a new random dot game. A masked examiner measured the stereoacuity three times per subject using the TNO test (at the beginning, at the end and after 6 months of the treatment). A second masked examiner measured stereoacuity using the new computerized game after the TNO masked evaluation. RESULTS: The Pearson’s correlation coefficient one test against the other was r(2) = 0.767 and the Bland–Altman plot was r(2)= 0.069 (mean difference −0.03 log sec). Using three categories: poor (840–300 seconds of arc), coarse (480–210 seconds of arc) and moderate–fine stereoacuity (210–30 seconds of arc). Positive predictive values were 89.5% for moderate–fine; 72.7% for coarse; and 90.0% for poor stereoacuity. In addition, the agreement was evaluated using the Kappa coefficient (K= 0.743) with a 0.95 confidence interval and lower and upper Kappa limits were (0.628 and 0.858), respectively. Kappa coefficient and limits were still good when analyzing data before (K =0.663, 0.420 and 0.906) and after the treatment (K= 0.765, 0.632 and 0.899). CONCLUSION: The Computerized Stereoscopic Game test allows the measure of stereoacuity. It can be used for both the purpose of detecting stereo vision deficits or tracking stereo vision development.
format Online
Article
Text
id pubmed-8275165
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-82751652021-07-14 An Evaluation of the Agreement Between a Computerized Stereoscopic Game Test and the TNO Stereoacuity Test Portela-Camino, Juan Antonio Martín-González, Santiago Ruiz-Alcocer, Javier Illarramendi-Mendicute, Igor Garrido-Mercado, Rafaela Clin Optom (Auckl) Original Research PURPOSE: Stereo-anomaly is commonly associated with amblyopia. An investigation was conducted to determine whether the measurements of stereoacuity obtained with the stereoacuity reference test (TNO Test) show an agreement with a computer stereoscope video game. METHODS: Thirty-two subjects (mean age 9.37±2.00 years) with an amblyopia history were selected for a blind and randomized study of stereoacuity improvement through a new random dot game. A masked examiner measured the stereoacuity three times per subject using the TNO test (at the beginning, at the end and after 6 months of the treatment). A second masked examiner measured stereoacuity using the new computerized game after the TNO masked evaluation. RESULTS: The Pearson’s correlation coefficient one test against the other was r(2) = 0.767 and the Bland–Altman plot was r(2)= 0.069 (mean difference −0.03 log sec). Using three categories: poor (840–300 seconds of arc), coarse (480–210 seconds of arc) and moderate–fine stereoacuity (210–30 seconds of arc). Positive predictive values were 89.5% for moderate–fine; 72.7% for coarse; and 90.0% for poor stereoacuity. In addition, the agreement was evaluated using the Kappa coefficient (K= 0.743) with a 0.95 confidence interval and lower and upper Kappa limits were (0.628 and 0.858), respectively. Kappa coefficient and limits were still good when analyzing data before (K =0.663, 0.420 and 0.906) and after the treatment (K= 0.765, 0.632 and 0.899). CONCLUSION: The Computerized Stereoscopic Game test allows the measure of stereoacuity. It can be used for both the purpose of detecting stereo vision deficits or tracking stereo vision development. Dove 2021-07-05 /pmc/articles/PMC8275165/ /pubmed/34267572 http://dx.doi.org/10.2147/OPTO.S308445 Text en © 2021 Portela-Camino et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Portela-Camino, Juan Antonio
Martín-González, Santiago
Ruiz-Alcocer, Javier
Illarramendi-Mendicute, Igor
Garrido-Mercado, Rafaela
An Evaluation of the Agreement Between a Computerized Stereoscopic Game Test and the TNO Stereoacuity Test
title An Evaluation of the Agreement Between a Computerized Stereoscopic Game Test and the TNO Stereoacuity Test
title_full An Evaluation of the Agreement Between a Computerized Stereoscopic Game Test and the TNO Stereoacuity Test
title_fullStr An Evaluation of the Agreement Between a Computerized Stereoscopic Game Test and the TNO Stereoacuity Test
title_full_unstemmed An Evaluation of the Agreement Between a Computerized Stereoscopic Game Test and the TNO Stereoacuity Test
title_short An Evaluation of the Agreement Between a Computerized Stereoscopic Game Test and the TNO Stereoacuity Test
title_sort evaluation of the agreement between a computerized stereoscopic game test and the tno stereoacuity test
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8275165/
https://www.ncbi.nlm.nih.gov/pubmed/34267572
http://dx.doi.org/10.2147/OPTO.S308445
work_keys_str_mv AT portelacaminojuanantonio anevaluationoftheagreementbetweenacomputerizedstereoscopicgametestandthetnostereoacuitytest
AT martingonzalezsantiago anevaluationoftheagreementbetweenacomputerizedstereoscopicgametestandthetnostereoacuitytest
AT ruizalcocerjavier anevaluationoftheagreementbetweenacomputerizedstereoscopicgametestandthetnostereoacuitytest
AT illarramendimendicuteigor anevaluationoftheagreementbetweenacomputerizedstereoscopicgametestandthetnostereoacuitytest
AT garridomercadorafaela anevaluationoftheagreementbetweenacomputerizedstereoscopicgametestandthetnostereoacuitytest
AT portelacaminojuanantonio evaluationoftheagreementbetweenacomputerizedstereoscopicgametestandthetnostereoacuitytest
AT martingonzalezsantiago evaluationoftheagreementbetweenacomputerizedstereoscopicgametestandthetnostereoacuitytest
AT ruizalcocerjavier evaluationoftheagreementbetweenacomputerizedstereoscopicgametestandthetnostereoacuitytest
AT illarramendimendicuteigor evaluationoftheagreementbetweenacomputerizedstereoscopicgametestandthetnostereoacuitytest
AT garridomercadorafaela evaluationoftheagreementbetweenacomputerizedstereoscopicgametestandthetnostereoacuitytest