Cargando…

The evaluation of a novel digital immunochromatographic assay with silver amplification to detect SARS-CoV-2

INTRODUCTION: Rapid antigen tests are convenient for diagnosing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2); however, they have lower sensitivities than nucleic acid amplification tests. In this study, we evaluated the diagnostic performance of Quick Chaser(®) Auto SARS-CoV-2, a nov...

Descripción completa

Detalles Bibliográficos
Autores principales: Kurihara, Yoko, Kiyasu, Yoshihiko, Akashi, Yusaku, Takeuchi, Yuto, Narahara, Kenji, Mori, Sunao, Takeshige, Tomonori, Notake, Shigeyuki, Ueda, Atsuo, Nakamura, Koji, Ishikawa, Hiroichi, Suzuki, Hiromichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8275475/
https://www.ncbi.nlm.nih.gov/pubmed/34294528
http://dx.doi.org/10.1016/j.jiac.2021.07.006
Descripción
Sumario:INTRODUCTION: Rapid antigen tests are convenient for diagnosing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2); however, they have lower sensitivities than nucleic acid amplification tests. In this study, we evaluated the diagnostic performance of Quick Chaser(®) Auto SARS-CoV-2, a novel digital immunochromatographic assay that is expected to have higher sensitivity than conventional antigen tests. METHODS: A prospective observational study was conducted between February 8 and March 24, 2021. We simultaneously obtained two nasopharyngeal samples, one for evaluation with the QuickChaser(®) Auto SARS-CoV-2 antigen test and the other for assessment with reverse transcription PCR (RT-PCR), considered the gold-standard reference test. The limit of detection (LOD) of the new antigen test was compared with those of four other commercially available rapid antigen tests. RESULTS: A total of 1401 samples were analyzed. SARS-CoV-2 was detected by reference RT-PCR in 83 (5.9%) samples, of which 36 (43.4%) were collected from symptomatic patients. The sensitivity, specificity, positive predictive value, and negative predictive value were 74.7% (95% confidence interval (CI): 64.0–83.6%), 99.8% (95% CI: 99.5–100%), 96.9% (95% CI: 89.2–99.6%), and 98.4% (95% CI: 97.6–99.0%), respectively. When limited to samples with a cycle threshold (Ct) < 30 or those from symptomatic patients, the sensitivity increased to 98.3% and 88.9%, respectively. The QuickChaser(®) Auto SARS-CoV-2 detected 34–120 copies/test, which indicated greater sensitivity than the other rapid antigen tests. CONCLUSIONS: QuickChaser(®) Auto SARS-CoV-2 showed sufficient sensitivity and specificity in clinical samples of symptomatic patients. The sensitivity was comparable to RT-PCR in samples with Ct < 30.