Cargando…
Gimme’ the Loop: Modifications to the Squid-Capture Technique for Laser-Fenestrated Thoracic Endografting
PURPOSE: Laser-fenestrated thoracic endovascular aortic repair (LfTEVAR) in the aortic arch with covering of the left subclavian artery (LSA) orifice is challenging. To optimize fenestration, the so-called squid-capture technique has been introduced. We present here a modification to the technique t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8276338/ https://www.ncbi.nlm.nih.gov/pubmed/33855878 http://dx.doi.org/10.1177/15266028211007475 |
_version_ | 1783721885291249664 |
---|---|
author | Mulorz, Joscha Knapsis, Artis Ertas, Neslihan Schelzig, Hubert Wagenhäuser, Markus Udo |
author_facet | Mulorz, Joscha Knapsis, Artis Ertas, Neslihan Schelzig, Hubert Wagenhäuser, Markus Udo |
author_sort | Mulorz, Joscha |
collection | PubMed |
description | PURPOSE: Laser-fenestrated thoracic endovascular aortic repair (LfTEVAR) in the aortic arch with covering of the left subclavian artery (LSA) orifice is challenging. To optimize fenestration, the so-called squid-capture technique has been introduced. We present here a modification to the technique that may help improve time-efficiency and safety. TECHNIQUE:: During the originally proposed squid-capture maneuver, the stent-graft is deployed in a preset snare wire loop, which is used to pull the stent graft toward the penetration device during in-situ fenestration. In preparation, the guidewire needs to be passed through the loop inside the aortic arch, which can be difficult and may predispose for embolic events. We propose here the creation of a “guidewire-through-snare-loop” configuration outside the body, which can then be reliably transferred into the aortic arch. The modified technique was successfully applied in a patient undergoing LfTEVAR for penetrating aortic ulcers. CONCLUSION: The proposed modification may help facilitate the squid-capture technique for LfTEVAR while saving time and resources. Given that LfTEVAR is becoming more frequently used, it is important to ensure technical success and safety of the procedure. |
format | Online Article Text |
id | pubmed-8276338 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-82763382021-08-03 Gimme’ the Loop: Modifications to the Squid-Capture Technique for Laser-Fenestrated Thoracic Endografting Mulorz, Joscha Knapsis, Artis Ertas, Neslihan Schelzig, Hubert Wagenhäuser, Markus Udo J Endovasc Ther Technical Notes PURPOSE: Laser-fenestrated thoracic endovascular aortic repair (LfTEVAR) in the aortic arch with covering of the left subclavian artery (LSA) orifice is challenging. To optimize fenestration, the so-called squid-capture technique has been introduced. We present here a modification to the technique that may help improve time-efficiency and safety. TECHNIQUE:: During the originally proposed squid-capture maneuver, the stent-graft is deployed in a preset snare wire loop, which is used to pull the stent graft toward the penetration device during in-situ fenestration. In preparation, the guidewire needs to be passed through the loop inside the aortic arch, which can be difficult and may predispose for embolic events. We propose here the creation of a “guidewire-through-snare-loop” configuration outside the body, which can then be reliably transferred into the aortic arch. The modified technique was successfully applied in a patient undergoing LfTEVAR for penetrating aortic ulcers. CONCLUSION: The proposed modification may help facilitate the squid-capture technique for LfTEVAR while saving time and resources. Given that LfTEVAR is becoming more frequently used, it is important to ensure technical success and safety of the procedure. SAGE Publications 2021-04-15 2021-08 /pmc/articles/PMC8276338/ /pubmed/33855878 http://dx.doi.org/10.1177/15266028211007475 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Technical Notes Mulorz, Joscha Knapsis, Artis Ertas, Neslihan Schelzig, Hubert Wagenhäuser, Markus Udo Gimme’ the Loop: Modifications to the Squid-Capture Technique for Laser-Fenestrated Thoracic Endografting |
title | Gimme’ the Loop: Modifications to the Squid-Capture Technique for Laser-Fenestrated Thoracic Endografting |
title_full | Gimme’ the Loop: Modifications to the Squid-Capture Technique for Laser-Fenestrated Thoracic Endografting |
title_fullStr | Gimme’ the Loop: Modifications to the Squid-Capture Technique for Laser-Fenestrated Thoracic Endografting |
title_full_unstemmed | Gimme’ the Loop: Modifications to the Squid-Capture Technique for Laser-Fenestrated Thoracic Endografting |
title_short | Gimme’ the Loop: Modifications to the Squid-Capture Technique for Laser-Fenestrated Thoracic Endografting |
title_sort | gimme’ the loop: modifications to the squid-capture technique for laser-fenestrated thoracic endografting |
topic | Technical Notes |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8276338/ https://www.ncbi.nlm.nih.gov/pubmed/33855878 http://dx.doi.org/10.1177/15266028211007475 |
work_keys_str_mv | AT mulorzjoscha gimmetheloopmodificationstothesquidcapturetechniqueforlaserfenestratedthoracicendografting AT knapsisartis gimmetheloopmodificationstothesquidcapturetechniqueforlaserfenestratedthoracicendografting AT ertasneslihan gimmetheloopmodificationstothesquidcapturetechniqueforlaserfenestratedthoracicendografting AT schelzighubert gimmetheloopmodificationstothesquidcapturetechniqueforlaserfenestratedthoracicendografting AT wagenhausermarkusudo gimmetheloopmodificationstothesquidcapturetechniqueforlaserfenestratedthoracicendografting |