Cargando…

The External Obturator Footprint Is a Usable, Accurate, and Reliable Landmark for Stem Depth in Direct Anterior THA

BACKGROUND: Previous CT and cadaver studies have suggested that the external obturator footprint might be used as a landmark for stem depth in direct anterior THA. Instructions on where to template this structure with small variability in height have been developed but have not been tested in daily...

Descripción completa

Detalles Bibliográficos
Autores principales: Vles, Georges, Meynen, Alexander, De Mulder, Jef, Ghijselings, Stijn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8277246/
https://www.ncbi.nlm.nih.gov/pubmed/33944807
http://dx.doi.org/10.1097/CORR.0000000000001799
_version_ 1783722040905170944
author Vles, Georges
Meynen, Alexander
De Mulder, Jef
Ghijselings, Stijn
author_facet Vles, Georges
Meynen, Alexander
De Mulder, Jef
Ghijselings, Stijn
author_sort Vles, Georges
collection PubMed
description BACKGROUND: Previous CT and cadaver studies have suggested that the external obturator footprint might be used as a landmark for stem depth in direct anterior THA. Instructions on where to template this structure with small variability in height have been developed but have not been tested in daily clinical practice. QUESTIONS/PURPOSES: In this study we sought to investigate the (1) usability, (2) accuracy, and (3) reliability of the external obturator footprint as a landmark for stem depth in direct anterior THA. METHODS: The distance between the superior border of the external obturator tendon and the shoulder of the stem was measured intraoperatively in all patients (n = 135) who underwent primary THA via a direct anterior approach performed by the senior author between November 2019 and October 2020. The landmark was considered useful when two of thre`e evaluators agreed that the intersection of the vertical line comprised of the lateral wall of the trochanteric fossa and the oblique line formed by the intertrochanteric crest was clearly visible on the preoperative planning radiograph, and when the landmark was furthermore identified with certainty during surgery. Accuracy was defined as the degree of agreement (categorical for thresholds of 2 and 5 mm, the latter representing the threshold for developing unphysiological gait parameters) between the intraoperative distance and radiographic distance as measured on intraoperative fluoroscopy images or postoperative radiographs, which were calibrated based on femoral head sizes in a software program commonly used for templating. Intrarater reliability was defined as the degree of agreement (categorical for thresholds of 1 mm, which we considered an acceptable measurement error) between the ratings of one observer, who measured the radiographic distance on two different occasions separated by a washout period of at least 2 weeks. Interrater reliability was defined as the degree of agreement (categorical for thresholds of 1 mm, which we considered an acceptable measurement error) between the ratings of three observers with varying levels of experience (a fellowship-trained hip surgeon, a hip surgery fellow, and a medical student). RESULTS: The landmark was considered useful in 77% (104 of 135) of patients who underwent direct anterior THA based on the observations that the trochanteric fossa was clearly visible on the planning radiograph in 117 patients and that the tendon was identified with certainty during surgery in 118 patients. There was good-to-excellent accuracy (intraclass correlation coefficient 0.75-087), and intrarater reliability (ICC 0.99) and interrater reliability (ICC 0.99) were both excellent. CONCLUSION: This clinical study showed that the external obturator footprint is a useful, accurate, and reliable landmark for stem depth in direct anterior THA. CLINICAL RELEVANCE: The external obturator landmark allows the surgeon to position the stem within a range of the templated depth that is beneath the threshold for the development of unphysiological gait parameters. Although strictly speaking it was found useful in 77% of patients in this study, we found that this percentage of usability can easily be improved to around 90% by providing the radiology lab technician with instructions to correct external rotation of the foot during the taking of the planning radiograph. Future studies could compare the established (in)equality in leg length in patients using the external obturator landmark with computer-assisted surgery.
format Online
Article
Text
id pubmed-8277246
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer
record_format MEDLINE/PubMed
spelling pubmed-82772462022-08-01 The External Obturator Footprint Is a Usable, Accurate, and Reliable Landmark for Stem Depth in Direct Anterior THA Vles, Georges Meynen, Alexander De Mulder, Jef Ghijselings, Stijn Clin Orthop Relat Res Basic Research BACKGROUND: Previous CT and cadaver studies have suggested that the external obturator footprint might be used as a landmark for stem depth in direct anterior THA. Instructions on where to template this structure with small variability in height have been developed but have not been tested in daily clinical practice. QUESTIONS/PURPOSES: In this study we sought to investigate the (1) usability, (2) accuracy, and (3) reliability of the external obturator footprint as a landmark for stem depth in direct anterior THA. METHODS: The distance between the superior border of the external obturator tendon and the shoulder of the stem was measured intraoperatively in all patients (n = 135) who underwent primary THA via a direct anterior approach performed by the senior author between November 2019 and October 2020. The landmark was considered useful when two of thre`e evaluators agreed that the intersection of the vertical line comprised of the lateral wall of the trochanteric fossa and the oblique line formed by the intertrochanteric crest was clearly visible on the preoperative planning radiograph, and when the landmark was furthermore identified with certainty during surgery. Accuracy was defined as the degree of agreement (categorical for thresholds of 2 and 5 mm, the latter representing the threshold for developing unphysiological gait parameters) between the intraoperative distance and radiographic distance as measured on intraoperative fluoroscopy images or postoperative radiographs, which were calibrated based on femoral head sizes in a software program commonly used for templating. Intrarater reliability was defined as the degree of agreement (categorical for thresholds of 1 mm, which we considered an acceptable measurement error) between the ratings of one observer, who measured the radiographic distance on two different occasions separated by a washout period of at least 2 weeks. Interrater reliability was defined as the degree of agreement (categorical for thresholds of 1 mm, which we considered an acceptable measurement error) between the ratings of three observers with varying levels of experience (a fellowship-trained hip surgeon, a hip surgery fellow, and a medical student). RESULTS: The landmark was considered useful in 77% (104 of 135) of patients who underwent direct anterior THA based on the observations that the trochanteric fossa was clearly visible on the planning radiograph in 117 patients and that the tendon was identified with certainty during surgery in 118 patients. There was good-to-excellent accuracy (intraclass correlation coefficient 0.75-087), and intrarater reliability (ICC 0.99) and interrater reliability (ICC 0.99) were both excellent. CONCLUSION: This clinical study showed that the external obturator footprint is a useful, accurate, and reliable landmark for stem depth in direct anterior THA. CLINICAL RELEVANCE: The external obturator landmark allows the surgeon to position the stem within a range of the templated depth that is beneath the threshold for the development of unphysiological gait parameters. Although strictly speaking it was found useful in 77% of patients in this study, we found that this percentage of usability can easily be improved to around 90% by providing the radiology lab technician with instructions to correct external rotation of the foot during the taking of the planning radiograph. Future studies could compare the established (in)equality in leg length in patients using the external obturator landmark with computer-assisted surgery. Wolters Kluwer 2021-08 2021-05-04 /pmc/articles/PMC8277246/ /pubmed/33944807 http://dx.doi.org/10.1097/CORR.0000000000001799 Text en Copyright © 2021 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the Association of Bone and Joint Surgeons https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Basic Research
Vles, Georges
Meynen, Alexander
De Mulder, Jef
Ghijselings, Stijn
The External Obturator Footprint Is a Usable, Accurate, and Reliable Landmark for Stem Depth in Direct Anterior THA
title The External Obturator Footprint Is a Usable, Accurate, and Reliable Landmark for Stem Depth in Direct Anterior THA
title_full The External Obturator Footprint Is a Usable, Accurate, and Reliable Landmark for Stem Depth in Direct Anterior THA
title_fullStr The External Obturator Footprint Is a Usable, Accurate, and Reliable Landmark for Stem Depth in Direct Anterior THA
title_full_unstemmed The External Obturator Footprint Is a Usable, Accurate, and Reliable Landmark for Stem Depth in Direct Anterior THA
title_short The External Obturator Footprint Is a Usable, Accurate, and Reliable Landmark for Stem Depth in Direct Anterior THA
title_sort external obturator footprint is a usable, accurate, and reliable landmark for stem depth in direct anterior tha
topic Basic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8277246/
https://www.ncbi.nlm.nih.gov/pubmed/33944807
http://dx.doi.org/10.1097/CORR.0000000000001799
work_keys_str_mv AT vlesgeorges theexternalobturatorfootprintisausableaccurateandreliablelandmarkforstemdepthindirectanteriortha
AT meynenalexander theexternalobturatorfootprintisausableaccurateandreliablelandmarkforstemdepthindirectanteriortha
AT demulderjef theexternalobturatorfootprintisausableaccurateandreliablelandmarkforstemdepthindirectanteriortha
AT ghijselingsstijn theexternalobturatorfootprintisausableaccurateandreliablelandmarkforstemdepthindirectanteriortha
AT vlesgeorges externalobturatorfootprintisausableaccurateandreliablelandmarkforstemdepthindirectanteriortha
AT meynenalexander externalobturatorfootprintisausableaccurateandreliablelandmarkforstemdepthindirectanteriortha
AT demulderjef externalobturatorfootprintisausableaccurateandreliablelandmarkforstemdepthindirectanteriortha
AT ghijselingsstijn externalobturatorfootprintisausableaccurateandreliablelandmarkforstemdepthindirectanteriortha