Cargando…

First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers

PURPOSE: The FUSION-X-US-II prototype was developed to combine 3D-automated breast ultrasound (ABUS) and digital breast tomosynthesis in a single device without decompressing the breast. We evaluated the technical function, feasibility of the examination workflow, image quality, breast tissue covera...

Descripción completa

Detalles Bibliográficos
Autores principales: Schaefgen, Benedikt, Juskic, Marija, Hertel, Madeleine, Barr, Richard G., Radicke, Marcus, Stieber, Anne, Hennigs, André, Riedel, Fabian, Sohn, Christof, Heil, Joerg, Golatta, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8277634/
https://www.ncbi.nlm.nih.gov/pubmed/33970324
http://dx.doi.org/10.1007/s00404-021-06081-z
_version_ 1783722115606773760
author Schaefgen, Benedikt
Juskic, Marija
Hertel, Madeleine
Barr, Richard G.
Radicke, Marcus
Stieber, Anne
Hennigs, André
Riedel, Fabian
Sohn, Christof
Heil, Joerg
Golatta, Michael
author_facet Schaefgen, Benedikt
Juskic, Marija
Hertel, Madeleine
Barr, Richard G.
Radicke, Marcus
Stieber, Anne
Hennigs, André
Riedel, Fabian
Sohn, Christof
Heil, Joerg
Golatta, Michael
author_sort Schaefgen, Benedikt
collection PubMed
description PURPOSE: The FUSION-X-US-II prototype was developed to combine 3D-automated breast ultrasound (ABUS) and digital breast tomosynthesis in a single device without decompressing the breast. We evaluated the technical function, feasibility of the examination workflow, image quality, breast tissue coverage and patient comfort of the ABUS device of the new prototype. METHODS: In this prospective feasibility study, the FUSION-X-US-II prototype was used to perform ABUS in 30 healthy volunteers without history of breast cancer. The ABUS images of the prototype were interpreted by a physician with specialization in breast diagnostics. Any detected lesions were measured and classified using BI-RADS(®) scores. Image quality was rated subjectively by the physician and coverage of the breast was measured. Patient comfort was evaluated by a questionnaire after the examination. RESULTS: One hundred and six scans were performed (61 × CC, 23 × ML, 22 × MLO) in 60 breasts. Image acquisition and processing by the prototype was fast and accurate. Breast coverage by ABUS was approximately 90.8%. Sixteen breast lesions (all benign, classified as BIRADS(®) 2) were identified. The examination was tolerated by all patients. CONCLUSION: The FUSION-X-US-II prototype allows a rapid ABUS scan with mostly high patient comfort. Technical developments resulted in an improvement of quality and coverage compared to previous prototype versions. The results are encouraging for a test of the prototype in a clinical setting in combination with tomosynthesis.
format Online
Article
Text
id pubmed-8277634
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-82776342021-07-20 First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers Schaefgen, Benedikt Juskic, Marija Hertel, Madeleine Barr, Richard G. Radicke, Marcus Stieber, Anne Hennigs, André Riedel, Fabian Sohn, Christof Heil, Joerg Golatta, Michael Arch Gynecol Obstet Images in Obstetrics and Gynecology PURPOSE: The FUSION-X-US-II prototype was developed to combine 3D-automated breast ultrasound (ABUS) and digital breast tomosynthesis in a single device without decompressing the breast. We evaluated the technical function, feasibility of the examination workflow, image quality, breast tissue coverage and patient comfort of the ABUS device of the new prototype. METHODS: In this prospective feasibility study, the FUSION-X-US-II prototype was used to perform ABUS in 30 healthy volunteers without history of breast cancer. The ABUS images of the prototype were interpreted by a physician with specialization in breast diagnostics. Any detected lesions were measured and classified using BI-RADS(®) scores. Image quality was rated subjectively by the physician and coverage of the breast was measured. Patient comfort was evaluated by a questionnaire after the examination. RESULTS: One hundred and six scans were performed (61 × CC, 23 × ML, 22 × MLO) in 60 breasts. Image acquisition and processing by the prototype was fast and accurate. Breast coverage by ABUS was approximately 90.8%. Sixteen breast lesions (all benign, classified as BIRADS(®) 2) were identified. The examination was tolerated by all patients. CONCLUSION: The FUSION-X-US-II prototype allows a rapid ABUS scan with mostly high patient comfort. Technical developments resulted in an improvement of quality and coverage compared to previous prototype versions. The results are encouraging for a test of the prototype in a clinical setting in combination with tomosynthesis. Springer Berlin Heidelberg 2021-05-10 2021 /pmc/articles/PMC8277634/ /pubmed/33970324 http://dx.doi.org/10.1007/s00404-021-06081-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Images in Obstetrics and Gynecology
Schaefgen, Benedikt
Juskic, Marija
Hertel, Madeleine
Barr, Richard G.
Radicke, Marcus
Stieber, Anne
Hennigs, André
Riedel, Fabian
Sohn, Christof
Heil, Joerg
Golatta, Michael
First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers
title First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers
title_full First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers
title_fullStr First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers
title_full_unstemmed First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers
title_short First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers
title_sort first proof-of-concept evaluation of the fusion-x-us-ii prototype for the performance of automated breast ultrasound in healthy volunteers
topic Images in Obstetrics and Gynecology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8277634/
https://www.ncbi.nlm.nih.gov/pubmed/33970324
http://dx.doi.org/10.1007/s00404-021-06081-z
work_keys_str_mv AT schaefgenbenedikt firstproofofconceptevaluationofthefusionxusiiprototypefortheperformanceofautomatedbreastultrasoundinhealthyvolunteers
AT juskicmarija firstproofofconceptevaluationofthefusionxusiiprototypefortheperformanceofautomatedbreastultrasoundinhealthyvolunteers
AT hertelmadeleine firstproofofconceptevaluationofthefusionxusiiprototypefortheperformanceofautomatedbreastultrasoundinhealthyvolunteers
AT barrrichardg firstproofofconceptevaluationofthefusionxusiiprototypefortheperformanceofautomatedbreastultrasoundinhealthyvolunteers
AT radickemarcus firstproofofconceptevaluationofthefusionxusiiprototypefortheperformanceofautomatedbreastultrasoundinhealthyvolunteers
AT stieberanne firstproofofconceptevaluationofthefusionxusiiprototypefortheperformanceofautomatedbreastultrasoundinhealthyvolunteers
AT hennigsandre firstproofofconceptevaluationofthefusionxusiiprototypefortheperformanceofautomatedbreastultrasoundinhealthyvolunteers
AT riedelfabian firstproofofconceptevaluationofthefusionxusiiprototypefortheperformanceofautomatedbreastultrasoundinhealthyvolunteers
AT sohnchristof firstproofofconceptevaluationofthefusionxusiiprototypefortheperformanceofautomatedbreastultrasoundinhealthyvolunteers
AT heiljoerg firstproofofconceptevaluationofthefusionxusiiprototypefortheperformanceofautomatedbreastultrasoundinhealthyvolunteers
AT golattamichael firstproofofconceptevaluationofthefusionxusiiprototypefortheperformanceofautomatedbreastultrasoundinhealthyvolunteers