Cargando…

Computational modeling of the cephalic arch predicts hemodynamic profiles in patients with brachiocephalic fistula access receiving hemodialysis

BACKGROUND: The most common configuration for arteriovenous fistula is brachiocephalic which often develop cephalic arch stenosis leading to the need for numerous procedures to maintain access patency. The hemodynamics that contributes to the development of cephalic arch stenosis is incompletely und...

Descripción completa

Detalles Bibliográficos
Autores principales: Hammes, Mary, Moya-Rodriguez, Andres, Bernstein, Cameron, Nathan, Sandeep, Navuluri, Rakesh, Basu, Anindita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8279323/
https://www.ncbi.nlm.nih.gov/pubmed/34260609
http://dx.doi.org/10.1371/journal.pone.0254016
_version_ 1783722430938742784
author Hammes, Mary
Moya-Rodriguez, Andres
Bernstein, Cameron
Nathan, Sandeep
Navuluri, Rakesh
Basu, Anindita
author_facet Hammes, Mary
Moya-Rodriguez, Andres
Bernstein, Cameron
Nathan, Sandeep
Navuluri, Rakesh
Basu, Anindita
author_sort Hammes, Mary
collection PubMed
description BACKGROUND: The most common configuration for arteriovenous fistula is brachiocephalic which often develop cephalic arch stenosis leading to the need for numerous procedures to maintain access patency. The hemodynamics that contributes to the development of cephalic arch stenosis is incompletely understood given the inability to accurately determine shear stress in the cephalic arch. In the current investigation our aim was to determine pressure, velocity and wall shear stress profiles in the cephalic arch in 3D using computational modeling as tools to understand stenosis. METHODS: Five subjects with brachiocephalic fistula access had protocol labs, Doppler, venogram and intravascular ultrasound imaging performed at 3 and 12 months. 3D reconstructions of the cephalic arch were generated by combining intravascular ultrasounds and venograms. Standard finite element analysis software was used to simulate time dependent blood flow in the cephalic arch with velocity, pressure and wall shear stress profiles generated. RESULTS: Our models generated from imaging and flow measurements at 3 and 12 months offer snapshots of the patient’s cephalic arch at a precise time point, although the remodeling of the vessel downstream of an arteriovenous fistula in patients undergoing regular dialysis is a dynamic process that persists over long periods of time (~ 5 years). The velocity and pressure increase at the cephalic bend cause abnormal hemodynamics most prominent along the inner wall of the terminal cephalic arch. The topology of the cephalic arch is highly variable between subjects and predictive of pathologic stenosis at later time points. CONCLUSIONS: Low flow velocity and wall pressure along the inner wall of the bend may provide possible nidus of endothelial activation that leads to stenosis and thrombosis. In addition, 3D modelling of the arch can indicate areas of stenosis that may be missed by venograms alone. Computational modeling reconstructed from 3D radiologic imaging and Doppler flow provides important insights into the hemodynamics of blood flow in arteriovenous fistula. This technique could be used in future studies to determine optimal flow to prevent endothelial damage for patients with arteriovenous fistula access.
format Online
Article
Text
id pubmed-8279323
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-82793232021-07-31 Computational modeling of the cephalic arch predicts hemodynamic profiles in patients with brachiocephalic fistula access receiving hemodialysis Hammes, Mary Moya-Rodriguez, Andres Bernstein, Cameron Nathan, Sandeep Navuluri, Rakesh Basu, Anindita PLoS One Research Article BACKGROUND: The most common configuration for arteriovenous fistula is brachiocephalic which often develop cephalic arch stenosis leading to the need for numerous procedures to maintain access patency. The hemodynamics that contributes to the development of cephalic arch stenosis is incompletely understood given the inability to accurately determine shear stress in the cephalic arch. In the current investigation our aim was to determine pressure, velocity and wall shear stress profiles in the cephalic arch in 3D using computational modeling as tools to understand stenosis. METHODS: Five subjects with brachiocephalic fistula access had protocol labs, Doppler, venogram and intravascular ultrasound imaging performed at 3 and 12 months. 3D reconstructions of the cephalic arch were generated by combining intravascular ultrasounds and venograms. Standard finite element analysis software was used to simulate time dependent blood flow in the cephalic arch with velocity, pressure and wall shear stress profiles generated. RESULTS: Our models generated from imaging and flow measurements at 3 and 12 months offer snapshots of the patient’s cephalic arch at a precise time point, although the remodeling of the vessel downstream of an arteriovenous fistula in patients undergoing regular dialysis is a dynamic process that persists over long periods of time (~ 5 years). The velocity and pressure increase at the cephalic bend cause abnormal hemodynamics most prominent along the inner wall of the terminal cephalic arch. The topology of the cephalic arch is highly variable between subjects and predictive of pathologic stenosis at later time points. CONCLUSIONS: Low flow velocity and wall pressure along the inner wall of the bend may provide possible nidus of endothelial activation that leads to stenosis and thrombosis. In addition, 3D modelling of the arch can indicate areas of stenosis that may be missed by venograms alone. Computational modeling reconstructed from 3D radiologic imaging and Doppler flow provides important insights into the hemodynamics of blood flow in arteriovenous fistula. This technique could be used in future studies to determine optimal flow to prevent endothelial damage for patients with arteriovenous fistula access. Public Library of Science 2021-07-14 /pmc/articles/PMC8279323/ /pubmed/34260609 http://dx.doi.org/10.1371/journal.pone.0254016 Text en © 2021 Hammes et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Hammes, Mary
Moya-Rodriguez, Andres
Bernstein, Cameron
Nathan, Sandeep
Navuluri, Rakesh
Basu, Anindita
Computational modeling of the cephalic arch predicts hemodynamic profiles in patients with brachiocephalic fistula access receiving hemodialysis
title Computational modeling of the cephalic arch predicts hemodynamic profiles in patients with brachiocephalic fistula access receiving hemodialysis
title_full Computational modeling of the cephalic arch predicts hemodynamic profiles in patients with brachiocephalic fistula access receiving hemodialysis
title_fullStr Computational modeling of the cephalic arch predicts hemodynamic profiles in patients with brachiocephalic fistula access receiving hemodialysis
title_full_unstemmed Computational modeling of the cephalic arch predicts hemodynamic profiles in patients with brachiocephalic fistula access receiving hemodialysis
title_short Computational modeling of the cephalic arch predicts hemodynamic profiles in patients with brachiocephalic fistula access receiving hemodialysis
title_sort computational modeling of the cephalic arch predicts hemodynamic profiles in patients with brachiocephalic fistula access receiving hemodialysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8279323/
https://www.ncbi.nlm.nih.gov/pubmed/34260609
http://dx.doi.org/10.1371/journal.pone.0254016
work_keys_str_mv AT hammesmary computationalmodelingofthecephalicarchpredictshemodynamicprofilesinpatientswithbrachiocephalicfistulaaccessreceivinghemodialysis
AT moyarodriguezandres computationalmodelingofthecephalicarchpredictshemodynamicprofilesinpatientswithbrachiocephalicfistulaaccessreceivinghemodialysis
AT bernsteincameron computationalmodelingofthecephalicarchpredictshemodynamicprofilesinpatientswithbrachiocephalicfistulaaccessreceivinghemodialysis
AT nathansandeep computationalmodelingofthecephalicarchpredictshemodynamicprofilesinpatientswithbrachiocephalicfistulaaccessreceivinghemodialysis
AT navulurirakesh computationalmodelingofthecephalicarchpredictshemodynamicprofilesinpatientswithbrachiocephalicfistulaaccessreceivinghemodialysis
AT basuanindita computationalmodelingofthecephalicarchpredictshemodynamicprofilesinpatientswithbrachiocephalicfistulaaccessreceivinghemodialysis