Cargando…

Value of 3-Dimensional Digital Subtraction Angiography for Detection and Classification of Intracranial Aneurysm Remnants After Clipping

BACKGROUND: The current gold standard for evaluation of the surgical result after intracranial aneurysm (IA) clipping is two-dimensional (2D) digital subtraction angiography (DSA). While there is growing evidence that postoperative 3D-DSA is superior to 2D-DSA, there is a lack of data on intraoperat...

Descripción completa

Detalles Bibliográficos
Autores principales: Marbacher, Serge, Halter, Matthias, Vogt, Deborah R, Kienzler, Jenny C, Magyar, Christian T J, Wanderer, Stefan, Anon, Javier, Diepers, Michael, Remonda, Luca, Fandino, Javier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8279834/
https://www.ncbi.nlm.nih.gov/pubmed/33861324
http://dx.doi.org/10.1093/ons/opab087
Descripción
Sumario:BACKGROUND: The current gold standard for evaluation of the surgical result after intracranial aneurysm (IA) clipping is two-dimensional (2D) digital subtraction angiography (DSA). While there is growing evidence that postoperative 3D-DSA is superior to 2D-DSA, there is a lack of data on intraoperative comparison. OBJECTIVE: To compare the diagnostic yield of detection of IA remnants in intra- and postoperative 3D-DSA, categorize the remnants based on 3D-DSA findings, and examine associations between missed 2D-DSA remnants and IA characteristics. METHODS: We evaluated 232 clipped IAs that were examined with intraoperative or postoperative 3D-DSA. Variables analyzed included patient demographics, IA and remnant distinguishing characteristics, and 2D- and 3D-DSA findings. Maximal IA remnant size detected by 3D-DSA was measured using a 3-point scale of 2-mm increments. RESULTS: Although 3D-DSA detected all clipped IA remnants, 2D-DSA missed 30.4% (7 of 23) and 38.9% (14 of 36) clipped IA remnants in intraoperative and postoperative imaging, respectively (95% CI: 30 [ 12, 49] %; P-value .023 and 39 [23, 55] %; P-value = <.001), and more often missed grade 1 (< 2 mm) clipped remnants (odds ratio [95% CI]: 4.3 [1.6, 12.7], P-value .005). CONCLUSION: Compared with 2D-DSA, 3D-DSA achieves a better diagnostic yield in the evaluation of clipped IA. Our proposed method to grade 3D-DSA remnants proved to be simple and practical. Especially small IA remnants have a high risk to be missed in 2D-DSA. We advocate routine use of either intraoperative or postoperative 3D-DSA as a baseline for lifelong follow-up of clipped IA.