Cargando…

Fe(3)O(4)-Polyaniline Nanocomposite for Non-enzymatic Electrochemical Detection of 2,4-Dichlorophenoxyacetic Acid

[Image: see text] This study proposes the development of an electrochemical sensor based on fabrication of a glassy carbon electrode (GCE) with Fe(3)O(4)-polyaniline (Fe(3)O(4)-PANI) nanocomposite, which was further used for enzyme-less detection of 2,4-dichlorophenoxyacetic acid (2,4-D) in aqueous...

Descripción completa

Detalles Bibliográficos
Autores principales: Goswami, Bhanita, Mahanta, Debajyoti
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8280687/
https://www.ncbi.nlm.nih.gov/pubmed/34278110
http://dx.doi.org/10.1021/acsomega.1c00983
Descripción
Sumario:[Image: see text] This study proposes the development of an electrochemical sensor based on fabrication of a glassy carbon electrode (GCE) with Fe(3)O(4)-polyaniline (Fe(3)O(4)-PANI) nanocomposite, which was further used for enzyme-less detection of 2,4-dichlorophenoxyacetic acid (2,4-D) in aqueous medium. Spectroscopic studies, microstructural studies, and elemental analysis established the formation of Fe(3)O(4) nanoparticles with polyaniline coating. The fabricated Fe(3)O(4)-PANI-GCE was characterized by electrochemical techniques like cyclic voltammetry and electrochemical impedance spectroscopy. The electrochemical response of 2,4-D on Fe(3)O(4)-PANI-GCE was evaluated by performing cyclic voltammetry and amperometry experiments. The synergistic effect of the composite causes the superior electrochemical behavior of Fe(3)O(4)-PANI-GCE toward the detection of 2,4-D. Amperometric measurements exhibited a linear concentration range from 1.35 to 2.7 μM. The sensitivity and detection limit were evaluated from the amperometric responses, which were found to be 4.62 × 10(–7) μA μM(–1) cm(–2) and 0.21 μM, respectively. The electrochemical sensing response could be attributed to adsorption of 2,4-D onto the Fe(3)O(4)-PANI-modified GCE (Fe(3)O(4)-PANI-GCE) surface. Fe(3)O(4)-PANI-GCE is found to be a simple, low-cost, and biocompatible non-enzymatic sensor for detection of 2,4-D in aqueous medium at ambient temperature.