Cargando…

Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis

BACKGROUND: Pelvic lymph node (PLN) metastasis has been included in the FIGO staging, so there is a need to determine the dose contribution from brachytherapy to ascertain the total delivered dose to the pelvic lymph nodes in cervical cancer. The aim of the study was to calculate the equivalent dose...

Descripción completa

Detalles Bibliográficos
Autores principales: Revathy, T, Vidyasagar, Nishant, Gururajachar, Janaki Manur, Thiruraj, Arul Ponni, Koushik, AS Kirthi, Alva, Ram Charith, Kumar, S Mohan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Via Medica 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8281908/
https://www.ncbi.nlm.nih.gov/pubmed/34277094
http://dx.doi.org/10.5603/RPOR.a2021.0047
_version_ 1783722910952718336
author Revathy, T
Vidyasagar, Nishant
Gururajachar, Janaki Manur
Thiruraj, Arul Ponni
Koushik, AS Kirthi
Alva, Ram Charith
Kumar, S Mohan
author_facet Revathy, T
Vidyasagar, Nishant
Gururajachar, Janaki Manur
Thiruraj, Arul Ponni
Koushik, AS Kirthi
Alva, Ram Charith
Kumar, S Mohan
author_sort Revathy, T
collection PubMed
description BACKGROUND: Pelvic lymph node (PLN) metastasis has been included in the FIGO staging, so there is a need to determine the dose contribution from brachytherapy to ascertain the total delivered dose to the pelvic lymph nodes in cervical cancer. The aim of the study was to calculate the equivalent dose in 2 Gy (EQD2) of the pelvic lymph nodes (PLNs) based on volume prescription using three applicators. MATERIALS AND METHODS: Forty-one patients who had undergone external beam radiotherapy followed by brachytherapy using tandem ovoids (TO), tandem ring (TR) and TO + free hand interstitial needles (TO + FH) applicators were taken for this study. 26 Gy in 4 fractions was prescribed to HRCTV. The external iliac node (ELN), internal iliac node (ILN) and obturator (OBT) were contoured and the median EQD2 of the lymph nodes was calculated. RESULTS: The median bilateral EQD2 values of ELN were 1.55 Gy (TR), 1.75 Gy (TO), 1.9 Gy (TO + FH), of ILN these were 2.57 Gy (TR), 3.27 Gy (TO), 3.04 Gy (TO + FH), and of OBT these were 3.69 Gy (TR), 4.46 Gy (TO), 4.69 Gy (TO + FH), respectively. The total median EQD2 values of TR, TO and TO + FH were 52.71 Gy, 53.03 Gy, and 53.88–62.73 Gy, respectively. CONCLUSION: Our study calculated the median EQD2 to the pelvic lymph nodes using three types of applicators in brachytherapy. This could serve as reference to decide on the EBRT boost dose while treating patients with enlarged pelvic lymph nodes.
format Online
Article
Text
id pubmed-8281908
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Via Medica
record_format MEDLINE/PubMed
spelling pubmed-82819082021-07-16 Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis Revathy, T Vidyasagar, Nishant Gururajachar, Janaki Manur Thiruraj, Arul Ponni Koushik, AS Kirthi Alva, Ram Charith Kumar, S Mohan Rep Pract Oncol Radiother Research Paper BACKGROUND: Pelvic lymph node (PLN) metastasis has been included in the FIGO staging, so there is a need to determine the dose contribution from brachytherapy to ascertain the total delivered dose to the pelvic lymph nodes in cervical cancer. The aim of the study was to calculate the equivalent dose in 2 Gy (EQD2) of the pelvic lymph nodes (PLNs) based on volume prescription using three applicators. MATERIALS AND METHODS: Forty-one patients who had undergone external beam radiotherapy followed by brachytherapy using tandem ovoids (TO), tandem ring (TR) and TO + free hand interstitial needles (TO + FH) applicators were taken for this study. 26 Gy in 4 fractions was prescribed to HRCTV. The external iliac node (ELN), internal iliac node (ILN) and obturator (OBT) were contoured and the median EQD2 of the lymph nodes was calculated. RESULTS: The median bilateral EQD2 values of ELN were 1.55 Gy (TR), 1.75 Gy (TO), 1.9 Gy (TO + FH), of ILN these were 2.57 Gy (TR), 3.27 Gy (TO), 3.04 Gy (TO + FH), and of OBT these were 3.69 Gy (TR), 4.46 Gy (TO), 4.69 Gy (TO + FH), respectively. The total median EQD2 values of TR, TO and TO + FH were 52.71 Gy, 53.03 Gy, and 53.88–62.73 Gy, respectively. CONCLUSION: Our study calculated the median EQD2 to the pelvic lymph nodes using three types of applicators in brachytherapy. This could serve as reference to decide on the EBRT boost dose while treating patients with enlarged pelvic lymph nodes. Via Medica 2021-06-09 /pmc/articles/PMC8281908/ /pubmed/34277094 http://dx.doi.org/10.5603/RPOR.a2021.0047 Text en © 2021 Greater Poland Cancer Centre https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially
spellingShingle Research Paper
Revathy, T
Vidyasagar, Nishant
Gururajachar, Janaki Manur
Thiruraj, Arul Ponni
Koushik, AS Kirthi
Alva, Ram Charith
Kumar, S Mohan
Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis
title Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis
title_full Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis
title_fullStr Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis
title_full_unstemmed Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis
title_short Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis
title_sort equivalent dose in 2 gy (eqd2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8281908/
https://www.ncbi.nlm.nih.gov/pubmed/34277094
http://dx.doi.org/10.5603/RPOR.a2021.0047
work_keys_str_mv AT revathyt equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis
AT vidyasagarnishant equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis
AT gururajacharjanakimanur equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis
AT thirurajarulponni equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis
AT koushikaskirthi equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis
AT alvaramcharith equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis
AT kumarsmohan equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis