Cargando…
Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis
BACKGROUND: Pelvic lymph node (PLN) metastasis has been included in the FIGO staging, so there is a need to determine the dose contribution from brachytherapy to ascertain the total delivered dose to the pelvic lymph nodes in cervical cancer. The aim of the study was to calculate the equivalent dose...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Via Medica
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8281908/ https://www.ncbi.nlm.nih.gov/pubmed/34277094 http://dx.doi.org/10.5603/RPOR.a2021.0047 |
_version_ | 1783722910952718336 |
---|---|
author | Revathy, T Vidyasagar, Nishant Gururajachar, Janaki Manur Thiruraj, Arul Ponni Koushik, AS Kirthi Alva, Ram Charith Kumar, S Mohan |
author_facet | Revathy, T Vidyasagar, Nishant Gururajachar, Janaki Manur Thiruraj, Arul Ponni Koushik, AS Kirthi Alva, Ram Charith Kumar, S Mohan |
author_sort | Revathy, T |
collection | PubMed |
description | BACKGROUND: Pelvic lymph node (PLN) metastasis has been included in the FIGO staging, so there is a need to determine the dose contribution from brachytherapy to ascertain the total delivered dose to the pelvic lymph nodes in cervical cancer. The aim of the study was to calculate the equivalent dose in 2 Gy (EQD2) of the pelvic lymph nodes (PLNs) based on volume prescription using three applicators. MATERIALS AND METHODS: Forty-one patients who had undergone external beam radiotherapy followed by brachytherapy using tandem ovoids (TO), tandem ring (TR) and TO + free hand interstitial needles (TO + FH) applicators were taken for this study. 26 Gy in 4 fractions was prescribed to HRCTV. The external iliac node (ELN), internal iliac node (ILN) and obturator (OBT) were contoured and the median EQD2 of the lymph nodes was calculated. RESULTS: The median bilateral EQD2 values of ELN were 1.55 Gy (TR), 1.75 Gy (TO), 1.9 Gy (TO + FH), of ILN these were 2.57 Gy (TR), 3.27 Gy (TO), 3.04 Gy (TO + FH), and of OBT these were 3.69 Gy (TR), 4.46 Gy (TO), 4.69 Gy (TO + FH), respectively. The total median EQD2 values of TR, TO and TO + FH were 52.71 Gy, 53.03 Gy, and 53.88–62.73 Gy, respectively. CONCLUSION: Our study calculated the median EQD2 to the pelvic lymph nodes using three types of applicators in brachytherapy. This could serve as reference to decide on the EBRT boost dose while treating patients with enlarged pelvic lymph nodes. |
format | Online Article Text |
id | pubmed-8281908 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Via Medica |
record_format | MEDLINE/PubMed |
spelling | pubmed-82819082021-07-16 Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis Revathy, T Vidyasagar, Nishant Gururajachar, Janaki Manur Thiruraj, Arul Ponni Koushik, AS Kirthi Alva, Ram Charith Kumar, S Mohan Rep Pract Oncol Radiother Research Paper BACKGROUND: Pelvic lymph node (PLN) metastasis has been included in the FIGO staging, so there is a need to determine the dose contribution from brachytherapy to ascertain the total delivered dose to the pelvic lymph nodes in cervical cancer. The aim of the study was to calculate the equivalent dose in 2 Gy (EQD2) of the pelvic lymph nodes (PLNs) based on volume prescription using three applicators. MATERIALS AND METHODS: Forty-one patients who had undergone external beam radiotherapy followed by brachytherapy using tandem ovoids (TO), tandem ring (TR) and TO + free hand interstitial needles (TO + FH) applicators were taken for this study. 26 Gy in 4 fractions was prescribed to HRCTV. The external iliac node (ELN), internal iliac node (ILN) and obturator (OBT) were contoured and the median EQD2 of the lymph nodes was calculated. RESULTS: The median bilateral EQD2 values of ELN were 1.55 Gy (TR), 1.75 Gy (TO), 1.9 Gy (TO + FH), of ILN these were 2.57 Gy (TR), 3.27 Gy (TO), 3.04 Gy (TO + FH), and of OBT these were 3.69 Gy (TR), 4.46 Gy (TO), 4.69 Gy (TO + FH), respectively. The total median EQD2 values of TR, TO and TO + FH were 52.71 Gy, 53.03 Gy, and 53.88–62.73 Gy, respectively. CONCLUSION: Our study calculated the median EQD2 to the pelvic lymph nodes using three types of applicators in brachytherapy. This could serve as reference to decide on the EBRT boost dose while treating patients with enlarged pelvic lymph nodes. Via Medica 2021-06-09 /pmc/articles/PMC8281908/ /pubmed/34277094 http://dx.doi.org/10.5603/RPOR.a2021.0047 Text en © 2021 Greater Poland Cancer Centre https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially |
spellingShingle | Research Paper Revathy, T Vidyasagar, Nishant Gururajachar, Janaki Manur Thiruraj, Arul Ponni Koushik, AS Kirthi Alva, Ram Charith Kumar, S Mohan Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis |
title | Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis |
title_full | Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis |
title_fullStr | Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis |
title_full_unstemmed | Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis |
title_short | Equivalent dose in 2 Gy (EQD2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis |
title_sort | equivalent dose in 2 gy (eqd2) to pelvic lymph nodes using volume based prescription for three brachytherapy applicators — a dosimetric retrospective analysis |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8281908/ https://www.ncbi.nlm.nih.gov/pubmed/34277094 http://dx.doi.org/10.5603/RPOR.a2021.0047 |
work_keys_str_mv | AT revathyt equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis AT vidyasagarnishant equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis AT gururajacharjanakimanur equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis AT thirurajarulponni equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis AT koushikaskirthi equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis AT alvaramcharith equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis AT kumarsmohan equivalentdosein2gyeqd2topelviclymphnodesusingvolumebasedprescriptionforthreebrachytherapyapplicatorsadosimetricretrospectiveanalysis |