Cargando…
Development and Validation of a Method for Preclinical Durability Evaluation of Linked Semiconstrained Total Elbow Replacement Prostheses
Total elbow replacement (TER) is a clinically successful procedure yet isolated, gross mechanical complications associated with implant durability persist. The objectives of this study were to (1) develop a clinically relevant in vitro methodology to replicate the reported damage modes and (2) demon...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8282162/ https://www.ncbi.nlm.nih.gov/pubmed/34497943 http://dx.doi.org/10.1177/2471549219826365 |
_version_ | 1783722960034463744 |
---|---|
author | Varadarajan, Ravikumar Kincaid, Brian L |
author_facet | Varadarajan, Ravikumar Kincaid, Brian L |
author_sort | Varadarajan, Ravikumar |
collection | PubMed |
description | Total elbow replacement (TER) is a clinically successful procedure yet isolated, gross mechanical complications associated with implant durability persist. The objectives of this study were to (1) develop a clinically relevant in vitro methodology to replicate the reported damage modes and (2) demonstrate durability improvements of a next-generation linked, semiconstrained design. Two TER prostheses were tested on a biaxial test frame at 1.4 Hz in 37 ± 3° deionized water through 0° to 130° flexion/extension at various load levels simulating high demand, posttraumatic patients until either component failure or run out to 200 000 cycles. The damage patterns of tested components were qualitatively compared to retrieved components to establish the clinical validity of the methodology. The run out load of design 1 was equivalent to 100 N weight in hand (WIH). Specimens tested at higher load levels exhibited multimodal damage consistent in appearance with the clinical literature. The minimum run out load of design 2 was 110 N WIH with no significant damage observed on the components. The methodology developed here was shown to reproduce the clinical damage modes associated with TER in high demand, posttraumatic patients. The method was able to distinguish performance differences within and between 2 different linked, semiconstrained designs. |
format | Online Article Text |
id | pubmed-8282162 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-82821622021-09-07 Development and Validation of a Method for Preclinical Durability Evaluation of Linked Semiconstrained Total Elbow Replacement Prostheses Varadarajan, Ravikumar Kincaid, Brian L J Shoulder Elb Arthroplast Original Scientific Research Total elbow replacement (TER) is a clinically successful procedure yet isolated, gross mechanical complications associated with implant durability persist. The objectives of this study were to (1) develop a clinically relevant in vitro methodology to replicate the reported damage modes and (2) demonstrate durability improvements of a next-generation linked, semiconstrained design. Two TER prostheses were tested on a biaxial test frame at 1.4 Hz in 37 ± 3° deionized water through 0° to 130° flexion/extension at various load levels simulating high demand, posttraumatic patients until either component failure or run out to 200 000 cycles. The damage patterns of tested components were qualitatively compared to retrieved components to establish the clinical validity of the methodology. The run out load of design 1 was equivalent to 100 N weight in hand (WIH). Specimens tested at higher load levels exhibited multimodal damage consistent in appearance with the clinical literature. The minimum run out load of design 2 was 110 N WIH with no significant damage observed on the components. The methodology developed here was shown to reproduce the clinical damage modes associated with TER in high demand, posttraumatic patients. The method was able to distinguish performance differences within and between 2 different linked, semiconstrained designs. SAGE Publications 2019-02-13 /pmc/articles/PMC8282162/ /pubmed/34497943 http://dx.doi.org/10.1177/2471549219826365 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Scientific Research Varadarajan, Ravikumar Kincaid, Brian L Development and Validation of a Method for Preclinical Durability Evaluation of Linked Semiconstrained Total Elbow Replacement Prostheses |
title | Development and Validation of a Method for Preclinical Durability Evaluation of Linked Semiconstrained Total Elbow Replacement Prostheses |
title_full | Development and Validation of a Method for Preclinical Durability Evaluation of Linked Semiconstrained Total Elbow Replacement Prostheses |
title_fullStr | Development and Validation of a Method for Preclinical Durability Evaluation of Linked Semiconstrained Total Elbow Replacement Prostheses |
title_full_unstemmed | Development and Validation of a Method for Preclinical Durability Evaluation of Linked Semiconstrained Total Elbow Replacement Prostheses |
title_short | Development and Validation of a Method for Preclinical Durability Evaluation of Linked Semiconstrained Total Elbow Replacement Prostheses |
title_sort | development and validation of a method for preclinical durability evaluation of linked semiconstrained total elbow replacement prostheses |
topic | Original Scientific Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8282162/ https://www.ncbi.nlm.nih.gov/pubmed/34497943 http://dx.doi.org/10.1177/2471549219826365 |
work_keys_str_mv | AT varadarajanravikumar developmentandvalidationofamethodforpreclinicaldurabilityevaluationoflinkedsemiconstrainedtotalelbowreplacementprostheses AT kincaidbrianl developmentandvalidationofamethodforpreclinicaldurabilityevaluationoflinkedsemiconstrainedtotalelbowreplacementprostheses |