Non-visualizable stent-occlusion after treatment of a fusiform PCA-aneurysm–a case report

We report the case of a 17-year-old woman with extensive subarachnoidal hemorrhage due to a ruptured fusiform aneurysm of the right PCA (posterior cerebral artery). Endovascular treatment was successfully performed using a LVIS-EVO-Stent (Microvention Incorporation, Tustin, USA) as well as several c...

Descripción completa

Detalles Bibliográficos
Autores principales: Städt, Michael, Holtmannspötter, Markus, Eff, Florian, Voit-Höhne, Heinz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8283140/
https://www.ncbi.nlm.nih.gov/pubmed/34306290
http://dx.doi.org/10.1016/j.radcr.2021.06.037
_version_ 1783723137795358720
author Städt, Michael
Holtmannspötter, Markus
Eff, Florian
Voit-Höhne, Heinz
author_facet Städt, Michael
Holtmannspötter, Markus
Eff, Florian
Voit-Höhne, Heinz
author_sort Städt, Michael
collection PubMed
description We report the case of a 17-year-old woman with extensive subarachnoidal hemorrhage due to a ruptured fusiform aneurysm of the right PCA (posterior cerebral artery). Endovascular treatment was successfully performed using a LVIS-EVO-Stent (Microvention Incorporation, Tustin, USA) as well as several coils. Short-term angiographic follow-up demonstrated extensive aneurysm progression and dilatation of the coil package, the stent could no longer be visualized and was not passable. Despite excellent distal vascular perfusion, a non-visible stent occlusion was suspected and subsequent occlusion of the patent artery was performed. We conclude that rapid progression of fusiform aneurysms after stent-assisted coiling may lead to expansion of the coil packages and non-assessability of the stent. Even with excellent distal perfusion, a stent-occlusion should be suspected in these cases. Therefore, we suggest short-term angiographic follow-up, especially after deploying multiple coil packages in fusiform aneurysms.
format Online
Article
Text
id pubmed-8283140
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-82831402021-07-22 Non-visualizable stent-occlusion after treatment of a fusiform PCA-aneurysm–a case report Städt, Michael Holtmannspötter, Markus Eff, Florian Voit-Höhne, Heinz Radiol Case Rep Case Report We report the case of a 17-year-old woman with extensive subarachnoidal hemorrhage due to a ruptured fusiform aneurysm of the right PCA (posterior cerebral artery). Endovascular treatment was successfully performed using a LVIS-EVO-Stent (Microvention Incorporation, Tustin, USA) as well as several coils. Short-term angiographic follow-up demonstrated extensive aneurysm progression and dilatation of the coil package, the stent could no longer be visualized and was not passable. Despite excellent distal vascular perfusion, a non-visible stent occlusion was suspected and subsequent occlusion of the patent artery was performed. We conclude that rapid progression of fusiform aneurysms after stent-assisted coiling may lead to expansion of the coil packages and non-assessability of the stent. Even with excellent distal perfusion, a stent-occlusion should be suspected in these cases. Therefore, we suggest short-term angiographic follow-up, especially after deploying multiple coil packages in fusiform aneurysms. Elsevier 2021-07-09 /pmc/articles/PMC8283140/ /pubmed/34306290 http://dx.doi.org/10.1016/j.radcr.2021.06.037 Text en © 2021 The Authors. Published by Elsevier Inc. on behalf of University of Washington. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Städt, Michael
Holtmannspötter, Markus
Eff, Florian
Voit-Höhne, Heinz
Non-visualizable stent-occlusion after treatment of a fusiform PCA-aneurysm–a case report
title Non-visualizable stent-occlusion after treatment of a fusiform PCA-aneurysm–a case report
title_full Non-visualizable stent-occlusion after treatment of a fusiform PCA-aneurysm–a case report
title_fullStr Non-visualizable stent-occlusion after treatment of a fusiform PCA-aneurysm–a case report
title_full_unstemmed Non-visualizable stent-occlusion after treatment of a fusiform PCA-aneurysm–a case report
title_short Non-visualizable stent-occlusion after treatment of a fusiform PCA-aneurysm–a case report
title_sort non-visualizable stent-occlusion after treatment of a fusiform pca-aneurysm–a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8283140/
https://www.ncbi.nlm.nih.gov/pubmed/34306290
http://dx.doi.org/10.1016/j.radcr.2021.06.037
work_keys_str_mv AT stadtmichael nonvisualizablestentocclusionaftertreatmentofafusiformpcaaneurysmacasereport
AT holtmannspottermarkus nonvisualizablestentocclusionaftertreatmentofafusiformpcaaneurysmacasereport
AT effflorian nonvisualizablestentocclusionaftertreatmentofafusiformpcaaneurysmacasereport
AT voithohneheinz nonvisualizablestentocclusionaftertreatmentofafusiformpcaaneurysmacasereport