RELIABILITY OF NOVEL ULTRASOUND MEASUREMENT FOR DETERMINING PATELLA POSITION

BACKGROUND: Patellar dislocations are common among youth athletes. A detailed understanding of patellofemoral anatomy is critical to determine patient prognosis and guide treatment and decision making. Recent literature suggests that measures of patella position relative to the trochlear groove may...

Descripción completa

Detalles Bibliográficos
Autores principales: Greenberg, Elliot, Rotunno, Nicole, Brown, Naomi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8284551/
http://dx.doi.org/10.1177/2325967121S00028
_version_ 1783723413923168256
author Greenberg, Elliot
Rotunno, Nicole
Brown, Naomi
author_facet Greenberg, Elliot
Rotunno, Nicole
Brown, Naomi
author_sort Greenberg, Elliot
collection PubMed
description BACKGROUND: Patellar dislocations are common among youth athletes. A detailed understanding of patellofemoral anatomy is critical to determine patient prognosis and guide treatment and decision making. Recent literature suggests that measures of patella position relative to the trochlear groove may help identify individuals at risk of repetitive dislocations. While these measures were described using MRI, it is plausible that ultrasound imaging can be utilized to provide similar information in a more cost-effective and time-efficient manner. PURPOSE: To determine intra and inter-rater reliability of two newly described ultrasound-based measures of patella positioning within two novice examiners. METHODS: Subjects were seated with the limb supported in full knee extension and neutral rotation. (Figure 1a) The examiners independently gathered all images and were blinded to each other’s measures for the duration of the study. The transducer was positioned transversely, on the anterior aspect of the knee such that the lateral trochlear ridge, center of trochlear groove, and proximal portion of the patellar tendon were all visible in cross-section. (Figure 1b) Two linear measures were obtained, representing the distance from midpoint of the patellar tendon to a) the center of trochlear groove (MPT-CTG) and b) the lateral trochlear ridge (MPT-LTR). Reliability was assessed using intraclass correlation coefficients (ICC). The average of two measures were used for data analysis. There was a minimum of 1 week between assessments for those subjects with repeated testing. RESULTS: A total of 11 subjects (mean age 15.3) without history of knee pathology were included. There were no significant differences (p>0.05) in either measurement between limbs with MPT-CTG and MPT-LTR values (mean±sd) as follows: MPT-CTG right 8.4mm ± 3.0, left 8.4mm ± 3.3; MPT-LTR right 12.2mm ± 2.7, left 11.6mm ± 2.3. For reliability analysis, each knee served as a discrete variable, yielding a total of 22 data points for evaluation. Inter-rater reliability (n=22) was moderate to good for both measures, with ICC values of 0.724 and 0.814 for MPT-CTG and MPT-LTR, respectively. Intra-rater reliability (n=10) was good to excellent with ICC values of 0.913 and 0.794 for MPT-CTG and MPT-LTR, respectively. (Table 1) CONCLUSIONS: This new measure of patella positioning demonstrated moderate to excellent reliability and may be a practical, cost-effective alternative to MRI. While it is encouraging that the subjects in this sample demonstrated no side-to-side differences in either measure, future research should focus on establishing criterion validity and reliability amongst individuals with patellar instability.
format Online
Article
Text
id pubmed-8284551
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-82845512021-07-30 RELIABILITY OF NOVEL ULTRASOUND MEASUREMENT FOR DETERMINING PATELLA POSITION Greenberg, Elliot Rotunno, Nicole Brown, Naomi Orthop J Sports Med Article BACKGROUND: Patellar dislocations are common among youth athletes. A detailed understanding of patellofemoral anatomy is critical to determine patient prognosis and guide treatment and decision making. Recent literature suggests that measures of patella position relative to the trochlear groove may help identify individuals at risk of repetitive dislocations. While these measures were described using MRI, it is plausible that ultrasound imaging can be utilized to provide similar information in a more cost-effective and time-efficient manner. PURPOSE: To determine intra and inter-rater reliability of two newly described ultrasound-based measures of patella positioning within two novice examiners. METHODS: Subjects were seated with the limb supported in full knee extension and neutral rotation. (Figure 1a) The examiners independently gathered all images and were blinded to each other’s measures for the duration of the study. The transducer was positioned transversely, on the anterior aspect of the knee such that the lateral trochlear ridge, center of trochlear groove, and proximal portion of the patellar tendon were all visible in cross-section. (Figure 1b) Two linear measures were obtained, representing the distance from midpoint of the patellar tendon to a) the center of trochlear groove (MPT-CTG) and b) the lateral trochlear ridge (MPT-LTR). Reliability was assessed using intraclass correlation coefficients (ICC). The average of two measures were used for data analysis. There was a minimum of 1 week between assessments for those subjects with repeated testing. RESULTS: A total of 11 subjects (mean age 15.3) without history of knee pathology were included. There were no significant differences (p>0.05) in either measurement between limbs with MPT-CTG and MPT-LTR values (mean±sd) as follows: MPT-CTG right 8.4mm ± 3.0, left 8.4mm ± 3.3; MPT-LTR right 12.2mm ± 2.7, left 11.6mm ± 2.3. For reliability analysis, each knee served as a discrete variable, yielding a total of 22 data points for evaluation. Inter-rater reliability (n=22) was moderate to good for both measures, with ICC values of 0.724 and 0.814 for MPT-CTG and MPT-LTR, respectively. Intra-rater reliability (n=10) was good to excellent with ICC values of 0.913 and 0.794 for MPT-CTG and MPT-LTR, respectively. (Table 1) CONCLUSIONS: This new measure of patella positioning demonstrated moderate to excellent reliability and may be a practical, cost-effective alternative to MRI. While it is encouraging that the subjects in this sample demonstrated no side-to-side differences in either measure, future research should focus on establishing criterion validity and reliability amongst individuals with patellar instability. SAGE Publications 2021-07-14 /pmc/articles/PMC8284551/ http://dx.doi.org/10.1177/2325967121S00028 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc-nd/4.0/This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For article reuse guidelines, please visit SAGE’s website at http://www.sagepub.com/journals-permissions.
spellingShingle Article
Greenberg, Elliot
Rotunno, Nicole
Brown, Naomi
RELIABILITY OF NOVEL ULTRASOUND MEASUREMENT FOR DETERMINING PATELLA POSITION
title RELIABILITY OF NOVEL ULTRASOUND MEASUREMENT FOR DETERMINING PATELLA POSITION
title_full RELIABILITY OF NOVEL ULTRASOUND MEASUREMENT FOR DETERMINING PATELLA POSITION
title_fullStr RELIABILITY OF NOVEL ULTRASOUND MEASUREMENT FOR DETERMINING PATELLA POSITION
title_full_unstemmed RELIABILITY OF NOVEL ULTRASOUND MEASUREMENT FOR DETERMINING PATELLA POSITION
title_short RELIABILITY OF NOVEL ULTRASOUND MEASUREMENT FOR DETERMINING PATELLA POSITION
title_sort reliability of novel ultrasound measurement for determining patella position
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8284551/
http://dx.doi.org/10.1177/2325967121S00028
work_keys_str_mv AT greenbergelliot reliabilityofnovelultrasoundmeasurementfordeterminingpatellaposition
AT rotunnonicole reliabilityofnovelultrasoundmeasurementfordeterminingpatellaposition
AT brownnaomi reliabilityofnovelultrasoundmeasurementfordeterminingpatellaposition