Cargando…

Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players

BACKGROUND: The use of a functional electromechanical dynamometer (FEMD) has been proposed as a valid and effective tool to evaluate specific movement patterns. The aim of this study was to determine the reliability of FEMD on swing eccentric hamstring exercise (SEHE) measures in soccer players. MET...

Descripción completa

Detalles Bibliográficos
Autores principales: Sánchez-Sánchez, Antonio Jesús, Chirosa-Ríos, Luis Javier, Chirosa-Ríos, Ignacio Jesús, García-Vega, Agustín José, Jerez-Mayorga, Daniel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PeerJ Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8286058/
https://www.ncbi.nlm.nih.gov/pubmed/34316399
http://dx.doi.org/10.7717/peerj.11743
_version_ 1783723666147639296
author Sánchez-Sánchez, Antonio Jesús
Chirosa-Ríos, Luis Javier
Chirosa-Ríos, Ignacio Jesús
García-Vega, Agustín José
Jerez-Mayorga, Daniel
author_facet Sánchez-Sánchez, Antonio Jesús
Chirosa-Ríos, Luis Javier
Chirosa-Ríos, Ignacio Jesús
García-Vega, Agustín José
Jerez-Mayorga, Daniel
author_sort Sánchez-Sánchez, Antonio Jesús
collection PubMed
description BACKGROUND: The use of a functional electromechanical dynamometer (FEMD) has been proposed as a valid and effective tool to evaluate specific movement patterns. The aim of this study was to determine the reliability of FEMD on swing eccentric hamstring exercise (SEHE) measures in soccer players. METHODS: Nineteen federated male soccer players (20.74 ± 4.04 years) performed the SEHE at three different isokinetic velocities (20–40–60 cm/s). These evaluations were conducted in four sessions, two for familiarization and two for registration. The average and maximum load (N) of the three isokinetic velocities was calculated from the values obtained from the FEMD (Dynasystem(®), Bangalore). RESULTS: The main results of this research showed that the reliability was high for the average load in the condition of 40 cm/s, presenting the highest ICC value (0.94). For maximum load, reliability was high in the condition of 20 cm/s. The manifestation of the most reliable load was the maximum load (ICC = 0.91–0.87). CONCLUSIONS: FEMD (Dynasystem(®), Bangalore) is a reliable device to evaluate the eccentric strength of the hamstring muscles in soccer players.
format Online
Article
Text
id pubmed-8286058
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher PeerJ Inc.
record_format MEDLINE/PubMed
spelling pubmed-82860582021-07-26 Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players Sánchez-Sánchez, Antonio Jesús Chirosa-Ríos, Luis Javier Chirosa-Ríos, Ignacio Jesús García-Vega, Agustín José Jerez-Mayorga, Daniel PeerJ Anatomy and Physiology BACKGROUND: The use of a functional electromechanical dynamometer (FEMD) has been proposed as a valid and effective tool to evaluate specific movement patterns. The aim of this study was to determine the reliability of FEMD on swing eccentric hamstring exercise (SEHE) measures in soccer players. METHODS: Nineteen federated male soccer players (20.74 ± 4.04 years) performed the SEHE at three different isokinetic velocities (20–40–60 cm/s). These evaluations were conducted in four sessions, two for familiarization and two for registration. The average and maximum load (N) of the three isokinetic velocities was calculated from the values obtained from the FEMD (Dynasystem(®), Bangalore). RESULTS: The main results of this research showed that the reliability was high for the average load in the condition of 40 cm/s, presenting the highest ICC value (0.94). For maximum load, reliability was high in the condition of 20 cm/s. The manifestation of the most reliable load was the maximum load (ICC = 0.91–0.87). CONCLUSIONS: FEMD (Dynasystem(®), Bangalore) is a reliable device to evaluate the eccentric strength of the hamstring muscles in soccer players. PeerJ Inc. 2021-07-14 /pmc/articles/PMC8286058/ /pubmed/34316399 http://dx.doi.org/10.7717/peerj.11743 Text en © 2021 Sánchez-Sánchez et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited.
spellingShingle Anatomy and Physiology
Sánchez-Sánchez, Antonio Jesús
Chirosa-Ríos, Luis Javier
Chirosa-Ríos, Ignacio Jesús
García-Vega, Agustín José
Jerez-Mayorga, Daniel
Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players
title Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players
title_full Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players
title_fullStr Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players
title_full_unstemmed Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players
title_short Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players
title_sort test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players
topic Anatomy and Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8286058/
https://www.ncbi.nlm.nih.gov/pubmed/34316399
http://dx.doi.org/10.7717/peerj.11743
work_keys_str_mv AT sanchezsanchezantoniojesus testretestreliabilityofafunctionalelectromechanicaldynamometeronswingeccentrichamstringexercisemeasuresinsoccerplayers
AT chirosariosluisjavier testretestreliabilityofafunctionalelectromechanicaldynamometeronswingeccentrichamstringexercisemeasuresinsoccerplayers
AT chirosariosignaciojesus testretestreliabilityofafunctionalelectromechanicaldynamometeronswingeccentrichamstringexercisemeasuresinsoccerplayers
AT garciavegaagustinjose testretestreliabilityofafunctionalelectromechanicaldynamometeronswingeccentrichamstringexercisemeasuresinsoccerplayers
AT jerezmayorgadaniel testretestreliabilityofafunctionalelectromechanicaldynamometeronswingeccentrichamstringexercisemeasuresinsoccerplayers