Cargando…
Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players
BACKGROUND: The use of a functional electromechanical dynamometer (FEMD) has been proposed as a valid and effective tool to evaluate specific movement patterns. The aim of this study was to determine the reliability of FEMD on swing eccentric hamstring exercise (SEHE) measures in soccer players. MET...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
PeerJ Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8286058/ https://www.ncbi.nlm.nih.gov/pubmed/34316399 http://dx.doi.org/10.7717/peerj.11743 |
_version_ | 1783723666147639296 |
---|---|
author | Sánchez-Sánchez, Antonio Jesús Chirosa-Ríos, Luis Javier Chirosa-Ríos, Ignacio Jesús García-Vega, Agustín José Jerez-Mayorga, Daniel |
author_facet | Sánchez-Sánchez, Antonio Jesús Chirosa-Ríos, Luis Javier Chirosa-Ríos, Ignacio Jesús García-Vega, Agustín José Jerez-Mayorga, Daniel |
author_sort | Sánchez-Sánchez, Antonio Jesús |
collection | PubMed |
description | BACKGROUND: The use of a functional electromechanical dynamometer (FEMD) has been proposed as a valid and effective tool to evaluate specific movement patterns. The aim of this study was to determine the reliability of FEMD on swing eccentric hamstring exercise (SEHE) measures in soccer players. METHODS: Nineteen federated male soccer players (20.74 ± 4.04 years) performed the SEHE at three different isokinetic velocities (20–40–60 cm/s). These evaluations were conducted in four sessions, two for familiarization and two for registration. The average and maximum load (N) of the three isokinetic velocities was calculated from the values obtained from the FEMD (Dynasystem(®), Bangalore). RESULTS: The main results of this research showed that the reliability was high for the average load in the condition of 40 cm/s, presenting the highest ICC value (0.94). For maximum load, reliability was high in the condition of 20 cm/s. The manifestation of the most reliable load was the maximum load (ICC = 0.91–0.87). CONCLUSIONS: FEMD (Dynasystem(®), Bangalore) is a reliable device to evaluate the eccentric strength of the hamstring muscles in soccer players. |
format | Online Article Text |
id | pubmed-8286058 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | PeerJ Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-82860582021-07-26 Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players Sánchez-Sánchez, Antonio Jesús Chirosa-Ríos, Luis Javier Chirosa-Ríos, Ignacio Jesús García-Vega, Agustín José Jerez-Mayorga, Daniel PeerJ Anatomy and Physiology BACKGROUND: The use of a functional electromechanical dynamometer (FEMD) has been proposed as a valid and effective tool to evaluate specific movement patterns. The aim of this study was to determine the reliability of FEMD on swing eccentric hamstring exercise (SEHE) measures in soccer players. METHODS: Nineteen federated male soccer players (20.74 ± 4.04 years) performed the SEHE at three different isokinetic velocities (20–40–60 cm/s). These evaluations were conducted in four sessions, two for familiarization and two for registration. The average and maximum load (N) of the three isokinetic velocities was calculated from the values obtained from the FEMD (Dynasystem(®), Bangalore). RESULTS: The main results of this research showed that the reliability was high for the average load in the condition of 40 cm/s, presenting the highest ICC value (0.94). For maximum load, reliability was high in the condition of 20 cm/s. The manifestation of the most reliable load was the maximum load (ICC = 0.91–0.87). CONCLUSIONS: FEMD (Dynasystem(®), Bangalore) is a reliable device to evaluate the eccentric strength of the hamstring muscles in soccer players. PeerJ Inc. 2021-07-14 /pmc/articles/PMC8286058/ /pubmed/34316399 http://dx.doi.org/10.7717/peerj.11743 Text en © 2021 Sánchez-Sánchez et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited. |
spellingShingle | Anatomy and Physiology Sánchez-Sánchez, Antonio Jesús Chirosa-Ríos, Luis Javier Chirosa-Ríos, Ignacio Jesús García-Vega, Agustín José Jerez-Mayorga, Daniel Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players |
title | Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players |
title_full | Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players |
title_fullStr | Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players |
title_full_unstemmed | Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players |
title_short | Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players |
title_sort | test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players |
topic | Anatomy and Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8286058/ https://www.ncbi.nlm.nih.gov/pubmed/34316399 http://dx.doi.org/10.7717/peerj.11743 |
work_keys_str_mv | AT sanchezsanchezantoniojesus testretestreliabilityofafunctionalelectromechanicaldynamometeronswingeccentrichamstringexercisemeasuresinsoccerplayers AT chirosariosluisjavier testretestreliabilityofafunctionalelectromechanicaldynamometeronswingeccentrichamstringexercisemeasuresinsoccerplayers AT chirosariosignaciojesus testretestreliabilityofafunctionalelectromechanicaldynamometeronswingeccentrichamstringexercisemeasuresinsoccerplayers AT garciavegaagustinjose testretestreliabilityofafunctionalelectromechanicaldynamometeronswingeccentrichamstringexercisemeasuresinsoccerplayers AT jerezmayorgadaniel testretestreliabilityofafunctionalelectromechanicaldynamometeronswingeccentrichamstringexercisemeasuresinsoccerplayers |