Cargando…

A comparison of laparoscopic procedures performed by novice medical students using 8K ultra-high-definition/two-dimensional and 2K high-definition/three-dimensional monitors

PURPOSE: 8K Ultra-high-definition (UHD) imaging has been developed in accordance with the progression of imaging technologies. We evaluated laparoscopic procedures performed by novice medical students using 2K/two-dimensional (2D), 2K/three-dimensional (3D) and 8K/2D monitors, with a particular focu...

Descripción completa

Detalles Bibliográficos
Autores principales: Shonaka, Tatsuya, Tani, Chikayoshi, Iwata, Hiroyoshi, Otani, Masahide, Hasegawa, Kimiharu, Matsuno, Naoto, Furukawa, Hiroyuki, Yoshida, Akitoshi, Sumi, Yasuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Singapore 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8286219/
https://www.ncbi.nlm.nih.gov/pubmed/33420823
http://dx.doi.org/10.1007/s00595-020-02215-z
_version_ 1783723701178466304
author Shonaka, Tatsuya
Tani, Chikayoshi
Iwata, Hiroyoshi
Otani, Masahide
Hasegawa, Kimiharu
Matsuno, Naoto
Furukawa, Hiroyuki
Yoshida, Akitoshi
Sumi, Yasuo
author_facet Shonaka, Tatsuya
Tani, Chikayoshi
Iwata, Hiroyoshi
Otani, Masahide
Hasegawa, Kimiharu
Matsuno, Naoto
Furukawa, Hiroyuki
Yoshida, Akitoshi
Sumi, Yasuo
author_sort Shonaka, Tatsuya
collection PubMed
description PURPOSE: 8K Ultra-high-definition (UHD) imaging has been developed in accordance with the progression of imaging technologies. We evaluated laparoscopic procedures performed by novice medical students using 2K/two-dimensional (2D), 2K/three-dimensional (3D) and 8K/2D monitors, with a particular focus on depth perception. METHODS: Nine medical students were enrolled. They performed two tasks using 2K/2D, 2K/3D and 8K/2D monitors. In Task 1, they were asked to grasp three metal rods with forceps using each hand. In Task 2, they were asked to grasp a metal rod with forceps held in the right hand, pass the metal rod through a metal ring and transfer it to their left hand. RESULTS: In Task 1, when performed with the dominant hand, the procedures performed using 2K/3D took a significantly shorter time than those performed using 8K/2D (P = 0.04). However, there was no significant difference among the three groups in the time required for procedures performed by the non-dominant hand. In Task 2, the procedure time with 2K/2D was significantly longer than that with 2K/3D or 8K/2D (P = 0.02). CONCLUSION: 2K/3D showed superior utility to 8K/2D for performing forceps procedures using the dominant hand. However, when the movement of both hands was coordinated (“bi-hand coordination”), the laparoscopic procedures were performed almost as deftly with 8K/2D and 2K/3D.
format Online
Article
Text
id pubmed-8286219
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Singapore
record_format MEDLINE/PubMed
spelling pubmed-82862192021-07-20 A comparison of laparoscopic procedures performed by novice medical students using 8K ultra-high-definition/two-dimensional and 2K high-definition/three-dimensional monitors Shonaka, Tatsuya Tani, Chikayoshi Iwata, Hiroyoshi Otani, Masahide Hasegawa, Kimiharu Matsuno, Naoto Furukawa, Hiroyuki Yoshida, Akitoshi Sumi, Yasuo Surg Today Original Article PURPOSE: 8K Ultra-high-definition (UHD) imaging has been developed in accordance with the progression of imaging technologies. We evaluated laparoscopic procedures performed by novice medical students using 2K/two-dimensional (2D), 2K/three-dimensional (3D) and 8K/2D monitors, with a particular focus on depth perception. METHODS: Nine medical students were enrolled. They performed two tasks using 2K/2D, 2K/3D and 8K/2D monitors. In Task 1, they were asked to grasp three metal rods with forceps using each hand. In Task 2, they were asked to grasp a metal rod with forceps held in the right hand, pass the metal rod through a metal ring and transfer it to their left hand. RESULTS: In Task 1, when performed with the dominant hand, the procedures performed using 2K/3D took a significantly shorter time than those performed using 8K/2D (P = 0.04). However, there was no significant difference among the three groups in the time required for procedures performed by the non-dominant hand. In Task 2, the procedure time with 2K/2D was significantly longer than that with 2K/3D or 8K/2D (P = 0.02). CONCLUSION: 2K/3D showed superior utility to 8K/2D for performing forceps procedures using the dominant hand. However, when the movement of both hands was coordinated (“bi-hand coordination”), the laparoscopic procedures were performed almost as deftly with 8K/2D and 2K/3D. Springer Singapore 2021-01-09 2021 /pmc/articles/PMC8286219/ /pubmed/33420823 http://dx.doi.org/10.1007/s00595-020-02215-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Shonaka, Tatsuya
Tani, Chikayoshi
Iwata, Hiroyoshi
Otani, Masahide
Hasegawa, Kimiharu
Matsuno, Naoto
Furukawa, Hiroyuki
Yoshida, Akitoshi
Sumi, Yasuo
A comparison of laparoscopic procedures performed by novice medical students using 8K ultra-high-definition/two-dimensional and 2K high-definition/three-dimensional monitors
title A comparison of laparoscopic procedures performed by novice medical students using 8K ultra-high-definition/two-dimensional and 2K high-definition/three-dimensional monitors
title_full A comparison of laparoscopic procedures performed by novice medical students using 8K ultra-high-definition/two-dimensional and 2K high-definition/three-dimensional monitors
title_fullStr A comparison of laparoscopic procedures performed by novice medical students using 8K ultra-high-definition/two-dimensional and 2K high-definition/three-dimensional monitors
title_full_unstemmed A comparison of laparoscopic procedures performed by novice medical students using 8K ultra-high-definition/two-dimensional and 2K high-definition/three-dimensional monitors
title_short A comparison of laparoscopic procedures performed by novice medical students using 8K ultra-high-definition/two-dimensional and 2K high-definition/three-dimensional monitors
title_sort comparison of laparoscopic procedures performed by novice medical students using 8k ultra-high-definition/two-dimensional and 2k high-definition/three-dimensional monitors
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8286219/
https://www.ncbi.nlm.nih.gov/pubmed/33420823
http://dx.doi.org/10.1007/s00595-020-02215-z
work_keys_str_mv AT shonakatatsuya acomparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT tanichikayoshi acomparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT iwatahiroyoshi acomparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT otanimasahide acomparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT hasegawakimiharu acomparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT matsunonaoto acomparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT furukawahiroyuki acomparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT yoshidaakitoshi acomparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT sumiyasuo acomparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT shonakatatsuya comparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT tanichikayoshi comparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT iwatahiroyoshi comparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT otanimasahide comparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT hasegawakimiharu comparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT matsunonaoto comparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT furukawahiroyuki comparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT yoshidaakitoshi comparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors
AT sumiyasuo comparisonoflaparoscopicproceduresperformedbynovicemedicalstudentsusing8kultrahighdefinitiontwodimensionaland2khighdefinitionthreedimensionalmonitors